Sit gas block Nova 0820010 is a gas control valve for heating and industrial burner applications, rated for 24 VAC operation with maximum flow rates of 5.3 m³/h (Class D I) and 6.5 m³/h (Class D II). Pilot torque of…

SKU 3G-CBM-00366

Also listed as: BLO 05110 · BLO-05110

Brand
SIT
Item
Gas block Nova 0820010
Category
Gas Controls
UNSPSC
40142201 — Gas regulators
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

SIT
electrical
24 VAC
pilot torque
7 Nm
flange torque
3 Nm
pressure loss
5 mbar
pilot connection
Ø 4 mm, Ø 6 mm or Ø 1/4 pipes
class d i family flow
5.3 m³/h
class d ii family flow
6.5 m³/h
class d iii family flow
8.1 kg/h

Datasheet Content

SIT Group 8 2 0 N O VA M U LT I F U N C T I O N A L G A S C O N T R O L THERMOELECTRIC FLAME SUPERVISION DEVICE SERVO-CONTROLLED PRESSURE REGULATOR AUTOMATIC SHUT-OFF VALVE PIN 63AP7060/2 M U LT I F U N C T I O N A L GAS SINGLE-CONTROL Multifunctional control with thermoelectric flame supervision device, single-control knob (Off, Pilot, On), restart interlock, servo-controlled pressure regulator, on/off electric solenoid. A step opening ignition device can be fitted on request. The 820 NOVA is suitable for use with boilers, catering equipment, hot air generators, radiators and other heating appliances. MAIN FEATURES Control knob with Off, Pilot and On positions. Thermoelectric flame supervision device with re-start interlock. Near silent shut-off valve. Servo-controlled pressure regulator. Step opening ignition device (optional). Main gas flow control (optional). Pilot outlet with gas flow adjustment screw. Inlet and pilot filters. Inlet and outlet pressure test points. Threaded gas inlet and outlet with provision for flange connection. Connection for combustion chamber pressure regulator compensation. DESCRIPTION 1 Control knob 9 Actuation valve 2 Pressure regulator cap screw 10 Pilot outlet 3 Pilot gas rate adjuster 11 Main gas outlet 4 Thermocouple connection 12 Holes (M5) for mounting flange 5 Alternative thermocouple connection 13 Supplementary fixing points for valve 6 Provision for accessories support 14 Connection point for combustion bracket chamber pressure regulator 7 Inlet pressure test point compensation 8 Outlet pressure test point 10 1 2 3 4 11 6 12 7 8 9 13 5 14 TECHNICAL DATA • Gas connections: Rp 1/2 ISO 7 ELECTRICAL DATA • Installation positions: any • Gas families: I, II and III Supply Voltage (AC) Consumption (mA) • Maximum gas inlet 240 V 50 Hz 25 pressure: 60 mbar 220 V 50 Hz 20 • Maximum outlet pressure 220 V 60 Hz 25 setting range: 3...30 mbar (optional 20...50) 24 V 50 Hz 210 • Working temperature 24 V 60 Hz 220 range: 0...70 °C (optional -20... +60°C) • Pressure regulator: Class B Electrical protection rating IP54 using 160-type connectors • Automatic shut-off valve: Class D (Class C on request) with screw and gasket - code 0.960.104 Data refer to EN 126 DIMENSIONS GAS FLOW AS A FUNCTION OF PRESSURE LOSS Q [m3/h d=0,6] CLASS D CLASSEDD 10 I Family (d = 0.45) Q = 7.5 m3/h ∆p = 5 mbar CLASSEC C CLASS II Family (d = 0.6) Q = 6.5 m3/h ∆p = 5 mbar 8 III Family (d = 1.7) Q = 8.1 kg/h ∆p = 5 mbar 6 CLASS C 4 I Family (d = 0.45) Q = 5.3 m3/h ∆p = 5 mbar 2 II Family (d = 0.6) Q = 4.6 m3/h ∆p = 5 mbar 0 III Family (d = 1.7) Q = 5.8 kg/h ∆p = 5 mbar 5 10 ∆p [mbar] ACTUATION Pilot flame ignition Press the control knob and rotate to Pilot . Press the knob and ignite the pilot flame, keeping the knob fully fig. 1 depressed for a few seconds (fig. 1). Release the knob and check the pilot flame stays on, otherwise repeat the ignition procedure. Main burner ignition Slightly depress the control knob and rotate to On (fig. 2). When the automatic valve is powered, the gas flow to the main burner is fig. 2 opened. Valves with a step opening ignition device reach the maximum rate of flow after approx. 10 seconds. Pilot position To keep the main burner off and the pilot flame on, slightly depress the control knob and rotate to Pilot . fig. 3 Shut-down Slightly depress the control knob and rotate to Off (fig. 3). CAUTION: The re-start interlock device prevents the appliance from re-igniting until the flame supervision device has interrupted the gas flow. After this stage (i.e. when the magnet unit has closed) it is possible to re- ignite the appliance. GAS FLOW SET TO EN 88 Q = [m3/h d=0.6] 14 12 CLASS C 10 Inlet pressure range 8 Type of gas 2L 6 Nominal Max. Min. 4 2H 20 25 17 2H 2L 25 30 20 2 Outlet pressure tolerance +10%...-15% 0 6 8 10 12 14 16 18 Pu [mbar] Q = [m3/h d=0.6] 14 12 CLASS D 10 Inlet pressure range 8 2L Type of gas 6 Nominal Max. Min. 4 2H 20 25 17 2H 2 2L 25 30 20 0 Outlet pressure tolerance +10%...-15% 6 8 10 12 14 16 18 Pu [mbar] INSTALLATION Main gas connection The connection must be made using gas pipes with Rp 1/2 ISO 7. Torque: 25 Nm. If optional flanges are used, first screw the pipes onto the flanges and then the flanges onto the valve. Recommended torque for flange fixing screws: 3 Nm. Connection to the pilot burner Ø 4 mm, Ø 6 mm or Ø 1/4 pipes can be used. Use appropriately sized nut and olive. Tighten to 7 Nm torque. Connection to the combustion chamber The “air” section of the pressure regulator may be connected to the combustion chamber if the latter is under pressure. Use the SIT fittings provided. Torque: 1 Nm Electrical connections The use of special connectors is recommended for the mains powered versions. In order to ensure that the valve is connected to the appliance’s earth circuit, always use the power connector with the earth terminal, fixing it with the appropriate screw. The 24 VAC versions must be powered by an isolating transformer (at a very low safety voltage as per EN 60742). Use AMP 6.3x0.8 mm DIN 46244 terminals for the connection. Make the connections according to the specific standards for the appliance. All relevant safety devices (e.g. the overheat thermostat) must cut off the power supply to the magnet unit. CAUTION: When all the connections have been completed, check the gas seals and wiring insulation. V~ 2 4 6 8 10 12 WIRING DIAGRAMS V~ Ambient thermostat SETTINGS AND ADJUSTMENTS Checking the inlet and oulet pressure Loosen the test-point screws provided to check inlet and outlet pressure. Tighten the screws to the recommended torque of 2.5 Nm. Adjusting the outlet pressure Remove the plug (A), turn the screw (B) clockwise to increase outlet pressure and anticlockwise to reduce it. After setting, ensure plug (A) is properly secured. Overriding the pressure regulator For conversion to operation on third family gases replace the plug (A), the adjustment screw (B) and the spring (C) with the…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SIT Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Sit gas block Nova 0820010 is a gas control valve for heating and industrial burner applications, rated for 24 VAC operation with maximum flow rates of 5.3 m³/h (Class D I) and 6.5 m³/h (Class D II). Pilot torque of 7 Nm and minimal 5 mbar pressure loss ensure reliable combustion control in residential and commercial systems.

Frequently Asked Questions

What is the SIT 820 NOVA gas block used for?

The SIT 820 NOVA gas block is a multifunctional gas control for boilers, catering equipment, hot air generators, radiators, and other heating appliances. It combines a thermoelectric flame supervision device, servo-controlled pressure regulator, and automatic shut-off valve for safe combustion control in residential and commercial systems.

What are the specifications of the SIT 820 NOVA gas block?

The SIT 820 NOVA operates on 24 VAC with a pilot torque of 7 Nm and flange torque of 3 Nm. It delivers maximum flow rates of 5.3 m³/h (Class D I) and 6.5 m³/h (Class D II) at 5 mbar pressure loss. Gas connections are Rp 1/2 ISO 7, and working temperature range is 0 to 70 °C.

Where to buy the SIT 820 NOVA gas block in Singapore?

You can source the SIT 820 NOVA gas block through 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this gas control valve for heating and industrial burner applications.

How to install the SIT 820 NOVA gas block?

Install the SIT 820 NOVA in any position with Rp 1/2 ISO 7 threaded connections. Ensure the inlet pressure does not exceed 60 mbar and the working temperature stays between 0 and 70 °C. Use the provided pressure test points to verify inlet and outlet pressures during commissioning.

Used in

Common applications for SIT
Commercial boiler gas-control replacement — Sigma 845 / 848 on hot-water and steam boilers
Catering and commercial kitchen equipment — Eurosit 630 thermostatic valves on fryers, ovens, and steamers
Residential heating appliance service — NOVA 820 / 822 / 824 as OEM-replacement gas-control valves
Standing-pilot gas appliance refurbishment — Eurosit 630 and Minisit thermostatic controls
Industrial gas-fired process equipment — Sigma 848 modulating gas valves for burner integration

SIT Products

3G Electric supplies SIT gas controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Gas block Nova 0820056
SIT
Gas block Nova 0820056
Gas block Nova 0822111
SIT
Gas block Nova 0822111
Gas block Nova 0822114
SIT
Gas block Nova 0822114
Nova gas block 0820012
SIT
Nova gas block 0820012
Nova gas block 0820055
SIT
Nova gas block 0820055
Nova gas block 0820052
SIT
Nova gas block 0820052

More from SIT

View all SIT parts
Pilot light 3 flames 0160005
SIT
Pilot light 3 flames 0160005
Pilot light 2 flames 0140024
SIT
Pilot light 2 flames 0140024
Pilot light 1 flame 0150073
SIT
Pilot light 1 flame 0150073
Pilot light 1 flame 0140039
SIT
Pilot light 1 flame 0140039
SIT
SIT
Connector with cable 830 0960107
SIT
SIT
Gas block Sigma 0848108
SIT
SIT
Minisit gas block 0710750
SIT
SIT
Intermediate contact M9 X 1