Dwyer CO2 detector Modbus CDTA-5N000-LCD
Dwyer CDTA-5N000-LCD is a CO2 detector for indoor air quality monitoring, measuring CO2 to 5000 ppm alongside humidity and temperature. It operates on 10–42 VDC / 10–30 VAC with Modbus RTU and BACnet MS/TP…
SKU 3G-CBM-02247
Also listed as: DWY 34012 · DWY-34012
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
Dwyer CDTA-5N000-LCD is a CO2 detector for indoor air quality monitoring, measuring CO2 to 5000 ppm alongside humidity and temperature. It operates on 10–42 VDC / 10–30 VAC with Modbus RTU and BACnet MS/TP communication, fitting HVAC and building management applications.
Frequently Asked Questions
What is the Dwyer CDTA-5N000-LCD CO2 detector used for?
The Dwyer CDTA-5N000-LCD is used for indoor air quality monitoring in HVAC and building management systems. It measures CO2 levels up to 5000 ppm, humidity, and temperature, enabling demand-controlled ventilation and energy-efficient climate control in commercial and industrial spaces.
What are the specifications of the Dwyer CDTA-5N000-LCD?
The Dwyer CDTA-5N000-LCD measures CO2 from 0–5000 ppm, humidity 10–95% RH, and temperature 0 to 50 °C. It operates on 10–42 VDC / 10–30 VAC with 1.2 W peak power. Communication is Modbus RTU or BACnet MS/TP, with a CO2 response time of 2 minutes to 99%.
Where to buy the Dwyer CDTA-5N000-LCD in Singapore?
3G Electric supplies the Dwyer CDTA-5N000-LCD CO2 detector to Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this Dwyer measurement device.
How to install the Dwyer CDTA-5N000-LCD?
Mount the Dwyer CDTA-5N000-LCD on a wall in the occupied zone, away from direct airflow or heat sources. Set the RS-485 MAC address using the onboard DIP switches and select Modbus RTU or BACnet MS/TP protocol. Connect 10–42 VDC or 10–30 VAC power and the communication bus.
Used in
Common applications for DwyerDwyer Products
3G Electric supplies Dwyer measurement. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.