Dwyer CDTA-5E000-LCD Modbus CO2 detector
Dwyer CDTA-5E000-LCD is a Modbus CO2 detector for indoor air quality monitoring, measuring 0–2000 ppm with 2 min response time. It operates on 10–42 VDC / 10–30 VAC and communicates via RS-485 Modbus RTU or BACnet…
SKU 3G-CBM-02249
Also listed as: DWY 34016 · DWY-34016
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
Dwyer CDTA-5E000-LCD is a Modbus CO2 detector for indoor air quality monitoring, measuring 0–2000 ppm with 2 min response time. It operates on 10–42 VDC / 10–30 VAC and communicates via RS-485 Modbus RTU or BACnet MS/TP, suitable for HVAC and building automation systems.
Frequently Asked Questions
What is the Dwyer CDTA-5E000-LCD Modbus CO2 detector used for?
The Dwyer CDTA-5E000-LCD is used for indoor air quality monitoring in HVAC and building automation systems. It measures CO2 levels from 0 to 2000 ppm, along with humidity and temperature, and communicates via RS-485 Modbus RTU or BACnet MS/TP to enable demand-controlled ventilation and energy-efficient climate management.
What are the specifications of the Dwyer CDTA-5E000-LCD?
The Dwyer CDTA-5E000-LCD measures CO2 from 0 to 2000 ppm with ±40 ppm ±3% accuracy, humidity from 10 to 95% RH, and temperature from 0 to +50°C. It operates on 10–42 VDC or 10–30 VAC, consumes 1.2 watts peak, and has a 2-minute response time to 99% of step change.
Where to buy the Dwyer CDTA-5E000-LCD in Singapore?
3G Electric supplies the Dwyer CDTA-5E000-LCD to Singapore. We handle sourcing, logistics, customs clearance, and local delivery for industrial and commercial clients. Contact our team for pricing and lead time on this Modbus CO2 detector for HVAC and building automation projects.
How to install the Dwyer CDTA-5E000-LCD CO2 detector?
Install the Dwyer CDTA-5E000-LCD in a representative indoor location away from direct airflow, heat sources, and windows. Use the built-in DIP switches to set the RS-485 MAC address and select Modbus RTU or BACnet MS/TP protocol. Wire power (10–42 VDC or 10–30 VAC) and communication lines per the Dwyer manual.