Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
DwyerMeasurement

Dwyer NO2 gas transmitter GSTA-N

The Dwyer GSTA-N is a NO2 gas transmitter with high precision electrochemical sensor technology, designed for air quality monitoring and industrial emission control applications. It features four Ø5.16mm mounting…

SKU 3G-CBM-02251

Also listed as: DWY 36004 · DWY-36004

Brand
Dwyer
Item
NO2 gas transmitter GSTA-N
Category
Measurement
UNSPSC
41112412 — Pressure gauge
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Dwyer
type
NO2 gas transmitter
sensor
High precision electrochemical
certifications
CE, RoHS
mounting holes
4x Ø5.16mm

Datasheet Content

Série GSTA Transmetteur de gaz CO (monoxyde de carbone) et d’oxyde d’azote Capteur Electrochimique de Haute Précision, Sortie Universelle 3-23/64 [85] 3-45/64 4x Ø13/64 [5.16] 2-55/64 [94.06] 2-15/64 MOUNTING HOLES [73] 3-1/8 [56.75] 3-1/8 2-15/64 [107.95] [107.95] [57] 4-17/32 [115.09] 4-17/32 [115.09] 5-7/64 [129.78] 3-59/64 [100] La Série GSTA Transmetteurs de Monoxyde de Carbone/Oxyde d’azote SPÉCIFICATIONS surveille la concentration en gaz dans les parkings souterrains et quais de chargement. Le Capteur : Electrochimique, changeable sur site, 4 ans de durée de vie typique. monoxyde de carbone est communément utilisé pour mesurer les échappements des moteurs Calibrage recommandé tous les 6 mois. à essence, tandis que le dioxyde d’azote sert pour les moteurs diesel. Les sorties d’intensité Plage : CO : sélectionnable de 0-50 ppm jusqu’à 0-500 ppm ; NO2 : 10 ppm. et de voltage sélectionnables sur site permettent au transmetteur d’être utilisé avec presque Dérive : <5% par an dans l’air. tous les régulateurs de gestion technique du bâtiment. Concernant les appareils au monoxyde Zone de Couverture : 450 à 700 m2. de carbone, l’utilisateur peut sélectionner la plage de sortie de 0 à 50 ppm jusqu’à 500 ppm. Précision : CO=2% de lecture, NO2=3% de lecture Durant le calibrage. Les appareils de dioxyde d’azote sont livrés avec une plage standard de 0 à 10 ppm. La sortie Résolution : CO=1 ppm; NO2 = 0.1 ppm. peut être inverse pour une lecture 20 à 4 mA ou de 10 (5) à 0 VDC grâce à des commutateurs Limites de Température : Ambiante : -20 à +50°C ; DIP internes. Pour maximiser la précision de la Série GSTA, le capteur peut être calibré sur Stockage : Pour une meilleure espérance de vie du capteur, de 0 à +20°C. site à l’aide de l’affichage LCD à distance. Lorsque le capteur atteint sa fin de vie, l’affichage Limites d’Humidité : 5 à 90% HR constant ; 0 à 99% HR intermittent. indiquera qu’il a besoin d’être remplacé. Temps de Réponse : <45 secondes de 90% CO, <25 de 90% NO2. Réglage du Zéro et de l’Etendue : Via bouton poussoir et à l’aide d’un afficheur Modèle Gaz détecté Fixation Réf. A-449 optionnel. Boîtier : Verre résistant aux UV renforcé au polycarbonate. GSTA-C CO Murale DWY36002 Sortie : Commutateur sélectionnable de 4 à 20 mA (alimenté en boucle), de 0 à 5 V GSTA-N no2 Murale 3G-CBM-02251 @ 5 mA, ou de 0 à 10 V@ 5 mA ; Commutateur sélectionnable de 0 à 5 V / 1 à 5 V et GSTA-C-D CO Conduite DWY36006 de 0 à 10 V / 2 à 10 V ; Commutateur sélectionnable à sortie normale ou inversée. GSTA-N-D no2 Conduite DWY36008 Alimentation Electrique : Intensité de sortie = de 10 à 35 VDC ; Tension de sortie = de 15 à 35 VDC ou de 15 à 29 VAC. A-449, Affichage LCD à Distance (DWY80050) Raccordement Electrique : Bloc de jonction amovible, avec mise à l’arrêt pour raccord A-505, Capteur de CO de Rechange (DWY90030) de conduite. A-506, Capteur de NO2 de Rechange (DWY90032) Calibrage : Via boutons poussoirs à l’aide de l’afficheur auxiliaire A-449. A-507, Adapteur d’Etalonnage (DWY90036) L’étendue de concentration en gaz est réglable sur site. Poids : 0,45 kg. Homologations : CE, RoHS.

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dwyer Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Dwyer GSTA-N is a NO2 gas transmitter with high precision electrochemical sensor technology, designed for air quality monitoring and industrial emission control applications. It features four Ø5.16mm mounting holes for secure installation and holds CE and RoHS certifications for regulatory compliance in environmental monitoring systems.

Frequently Asked Questions

What is the Dwyer GSTA-N NO2 gas transmitter used for?

The Dwyer GSTA-N is used for monitoring nitrogen dioxide (NO2) concentrations in underground car parks, loading docks, and industrial emission control. It helps ensure air quality and safety by detecting diesel engine exhaust, with a standard range of 0 to 10 ppm.

What are the specifications of the Dwyer GSTA-N?

The Dwyer GSTA-N uses a high precision electrochemical sensor with a range of 0 to 10 ppm NO2, accuracy of 3% of reading, resolution of 0.1 ppm, and response time under 25 seconds for 90% of step change. It operates at -20 to +50 °C ambient and 5 to 90% RH continuous.

Where to buy the Dwyer GSTA-N in Singapore?

You can source the Dwyer GSTA-N NO2 gas transmitter through 3G Electric in Singapore. We provide procurement, logistics, customs clearance, and delivery services for this Dwyer model, ensuring compliance with local regulations for environmental monitoring systems.

How to install the Dwyer GSTA-N gas transmitter?

Mount the Dwyer GSTA-N using its four Ø5.16mm holes on a wall in the target area, ensuring proper airflow. Connect the universal output (4-20 mA, 0-5 V, or 0-10 V) to your building management system. Calibrate every six months using the remote LCD display and push-button zero/span adjustment.

Used in

Common applications for Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Products

3G Electric supplies Dwyer measurement. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
NO2 gas transmitter GSTA-N-D
Dwyer
NO2 gas transmitter GSTA-N-D
CO gas transmitter GSTA-C
Dwyer
CO gas transmitter GSTA-C
CO gas transmitter GSTA-C-D
Dwyer
CO gas transmitter GSTA-C-D
CO gas transmitter CMT200
Dwyer
CO gas transmitter CMT200
Dwyer
Dwyer
NO2 sensor replacement A-506
Dwyer
Dwyer
Transmitter 645-0

More from Dwyer

View all Dwyer parts
Magnehelic pressure gauge 2000-30PA
Dwyer
Magnehelic pressure gauge 2000-30PA
Flow meter FS 2
Dwyer
Flow meter FS 2
Dwyer
Dwyer
Average flow probe PAFS-1002
Dwyer
Dwyer
MAFS-48 metallic average flow probe
Dwyer
Dwyer
Transmitter 645-6
Dwyer
Dwyer
Current detector SCS-211125-R
Dwyer
Dwyer
Current transmitter SCT10-102
Dwyer
Dwyer
Current transmitter CCT 50-203