Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

3G Electric
Honeywell Relay MMI 813.23 - Burner Controls
HoneywellBurner Controls

Honeywell Relay MMI 813.23

Honeywell MMI 813.23 is a burner control unit with 5A total load capacity and IP 44 protection, compatible with ionization probe or IR oscillation detector flame detection. Delivers up to 2A output at 0.4 cos φ for…

SKU 3G-CBM-05911

Brand
Honeywell
Item
Relay MMI 813.23
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Honeywell
type
burner control unit
model
MMI 813.1
total load
5A, cos φ 0.4
flame detector
ionization probe or IR oscillation detector IRD 1020
mounting position
any
output 3 max load
2A, cos φ 0.2
protection degree
IP 44
output 4B max load
2A, cos φ 0.4
output 5 6C max load
1A, cos φ 0.4
amplifier sensitivity
1 µA
ionization current min
5 µA

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Honeywell Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Honeywell MMI 813.23 is a burner control unit with 5A total load capacity and IP 44 protection, compatible with ionization probe or IR oscillation detector flame detection. Delivers up to 2A output at 0.4 cos φ for burner management and safety applications.

Frequently Asked Questions

What is the Honeywell MMI 813.23 burner control used for?

The Honeywell MMI 813.23 is a burner control unit for forced-draught gas burners. It manages and monitors burner operation, supports two-stage or modulating firing with an air damper actuator, and uses an ionization probe or IRD 1020 IR oscillation detector for flame detection.

What are the specifications of the Honeywell MMI 813.23?

The Honeywell MMI 813.23 operates at 220/240 V, 50 Hz, with a total load of 5A at cos φ 0.4. It has IP 44 protection, amplifier sensitivity of 1 µA, minimum ionization current of 5 µA, and supports flame detection via ionization probe or IRD 1020 detector.

Where to buy the Honeywell MMI 813.23 in Singapore?

You can source the Honeywell MMI 813.23 from 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this burner control unit.

How to install the Honeywell MMI 813.23 burner control?

Mount the Honeywell MMI 813.23 in any position within an ambient temperature of -20°C to +60°C. Connect the ionization probe or IRD 1020 detector using cable up to 20 m. Ensure a 10A fast or 6A slow protection fuse is used. Follow EN 298 wiring guidelines.

Used in

Common applications for Honeywell
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits
Not sure this is the right part? Photo-identify it

Honeywell Products

3G Electric supplies Honeywell burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Relay MMI 810.13
Honeywell
Relay MMI 810.13
Relay MMI 810.33
Honeywell
Relay MMI 810.33
MMI 811.35 relay
Honeywell
MMI 811.35 relay

More from Honeywell

View all Honeywell parts
Relay MMI 810.40.34
Honeywell
Relay MMI 810.40.34
Relay FFW 930
Honeywell
Relay FFW 930
Relay MMI 816.1
Honeywell
Relay MMI 816.1
MMG 810.1 MOD 45 relay
Honeywell
MMG 810.1 MOD 45 relay
Relay MMI 810.1 MOD 43
Honeywell
Relay MMI 810.1 MOD 43
Relay TFI 812.10
Honeywell
Relay TFI 812.10
Relay CM 31 TW40/TS10
Honeywell
Relay CM 31 TW40/TS10
Relay TFI 812.05
Honeywell
Relay TFI 812.05

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first