Brahma Relay CM 11F TW1.5/TS5
Brahma CM 11F TW1.5/TS5 is an electronic burner control relay for atmospheric gas burners in intermittent operation. It features non-volatile lockout with manual reset and built-in flame ionization monitoring, with…
SKU 3G-CBM-06037
Also listed as: REL 45159 · REL-45159
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
Brahma CM 11F TW1.5/TS5 is an electronic burner control relay for atmospheric gas burners in intermittent operation. It features non-volatile lockout with manual reset and built-in flame ionization monitoring, with optional fan control integration for emissions-compliant installations.
Frequently Asked Questions
What is the Brahma CM 11F TW1.5/TS5 used for?
The Brahma CM 11F TW1.5/TS5 is an electronic burner control relay designed for atmospheric gas burners in intermittent operation. It is suitable for combi boilers, heating boilers, warm air generators, radiant heaters, and water heaters. It can be used with or without a fan and includes a built-in anti-emissions filter.
What are the specifications of the Brahma CM 11F TW1.5/TS5?
The Brahma CM 11F TW1.5/TS5 is a Microflat series electronic burner control relay with non-volatile lockout and manual reset. It features flame ionization monitoring, two independent safety contacts on the gas valve output, and a built-in E.M. filter. It is EC certified (CE Reg. No. 63AQ0625) per EN 298.
Where to buy the Brahma CM 11F TW1.5/TS5 in Singapore?
3G Electric supplies the Brahma CM 11F TW1.5/TS5 burner control relay to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this Brahma model.
How to install the Brahma CM 11F TW1.5/TS5?
Install the Brahma CM 11F TW1.5/TS5 according to the manufacturer's wiring diagram and safety guidelines. Ensure proper flame ionization probe positioning for reliable flame monitoring. The control features manual reset after lockout. Use a resistor (0–220 ohm) in series with the valve output if using rectified DC valves.
Used in
Common applications for BrahmaBrahma Products
3G Electric supplies Brahma burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.