Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

TG Aquastat capillary housing 1m internal adjustment 0/90°C - Thermostats
TGThermostats

TG Aquastat capillary housing 1m internal adjustment 0/90°C

TG aquastat capillary housing provides temperature control for hydronic systems with 1000 mm capillary length and 0/90°C range. Copper and PVC construction with PG 11 connection suits retrofit and new HVAC…

SKU 3G-CBM-06903

Also listed as: THG 45003 · THG-45003

Brand
TG
Item
Aquastat capillary housing 1m internal adjustment 0/90°C
Category
Thermostats
UNSPSC
39122229 — Temperature switch
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

TG
material
Cu + PVC
connection
PG 11
bulb length
73 mm
bulb diameter
6.5 mm
capillary length
1000 mm
temperature range
0/90°C

Datasheet Content

7K1-7K2 Termostato regolatore a capillare Termostato di regolazione in custodia a capillare con sensore a dilatazione di liquido e regolazione esterna con manopola (mod. 7K1) o regolazione interna a cacciavite (Mod. 7K2). 62 2 fori / holes 56 ~9 Ø 3 / 5 / 6,5 * * 53 Ø4 26 * vedi tabella 73 / 82 / 86 * Dimensioni (mm) 102 PG 11 ~18 40 Cu + PVC 1000 / 1500 *  7K1 62 2 fori / holes 56 Ø4 53 1000 26 102  7K1  7K2 5 / 6,5 73 / 95 PG 11 ~18 40  7K2 CODICE CAMPO DI GRADO TIPO DI REGOLAZIONE DIMENSIONI LUNGHEZZA REGOLAZIONE DI PROTEZIONE BULBO CAPILLARE °C mm mm interna esterna 7K1-6R326-00A 0 ÷ 60 °C • Ø 6,5 x 73 1000 7K1-1R326-00A 0 ÷ 90 °C • Ø 6,5 x 73 1000 7K1-1R336-00A 0 ÷ 90 °C • Ø 6,5 x 73 1500 IP43 7K1-XR338-01A 0 ÷ 150 °C • Ø 5 x 86 1500 7K1-HR337-00A 0 ÷ 300 °C • Ø 3 x 190 Inox 1500 7K1-FR336-00A -35 ÷ 35 °C • Ø 6,5 x 82 1500 7K1-6S326-00A 0 ÷ 60 °C • Ø 6,5 x 73 1000 7K1-6S326-01A 0 ÷ 60°C • Ø 5 x 95 Inox 1000 7K1-1S326-00A 0 ÷ 90 °C • Ø 6,5 x 73 1000 7K1-FS336-00A -35 ÷ 35 °C • Ø 6,5 x 82 1500 IP55 7K2-60326-00A 0 ÷ 60 °C • Ø 6,5 x 73 1000 7K2-60326-01A 0 ÷ 60 °C • Ø 5 x 95 Inox 1000 7K2-10326-00A 0 ÷ 90 °C • Ø 6,5 x 73 1000 7K6-05366-00A 5 °C fissa Ø 6,5 x 73 3000 *Grado di protezione IP43 oppure in contenitore stagno IP55 garantito montando l’apparecchio in posizione orizzontale e verticale con passacavo rivolto verso il basso. 10 NORMATIVE E OMOLOGAZIONI Rispondenti alla norma CE 0497 (PED) CARATTERISTICHE TECNICHE Tolleranza temp. min. ±5°C, temp. max. ±3 °C Gradiente termico 1°C/min Limite temperatura testa di comando T 85 Temperatura max di sopportazione dell’elemento sensibile T 120 Tipo di azione 1B Portata contatti: 16 (4)A 250V~ - 6 (1)A 400V~ Classe di isolamento I Categoria di sovratensione II Tensione impulsiva nominale 4 kV Morsetti: Utilizzare cavi resistenti al calore min. T 140 1 = apre il circuito all’aumentare della temperatura Messa a terra del dispositivo con morsetti a vite 2 = chiude il circuito all’aumentare della temperatura Situazione di inquinamento del dispositivo di comando 2 3 = comune INSTALLAZIONE Le operazioni di installazione di seguito descritte devono essere eseguite esclusivamente da personale qualificato rispettando le norme di sicurezza e le disposizioni delle leggi vigenti. Togliere tensione prima di effettuare qualsiasi operazione. Verificare che i dati di targa dell’apparecchio (tensione di alimentazione, portata contatti, ecc..) siano idonei alle condizioni di installazione. 7K1 1 Svitare le viti di fissaggio A, e 2 Effettuare i collegamenti 3 Rimontare il coperchio posizionando 4 Assicurare l’apparecchio alla quindi rimuovere il coperchio. elettrici utilizzando gli appositi la monopola in modo che si incastri parete tramite viti B. morsetti. correttamente sul perno del termostato regolatore. Quindi serrare le viti A di fissaggio. A A B NOTA: Il grado di protezione IP55 (Mod. 7K1-...S...) è garantito montando l’apparecchio in verticale con passacavo rivolto verso il basso. Il grado di protezione IP43 (Mod. 7K1-...R...) è garantito montando l’apparecchio in verticale con passacavo rivolto verso il basso e in orizzontale 7K2 1 Svitare le viti di fissaggio A, e 2 Effettuare i collegamenti 3 Impostare la 4 Rimontare il coperchio serrando 5 Assicurare l’apparecchio alla quindi rimuovere il coperchio. elettrici utilizzando gli temperatura di le viti A di fissaggio. parete tramite viti B. appositi morsetti. intervento ruotando la camma C. A - + A B C OPZIONI Altri campi di temperatura sono disponibili su richiesta.…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

TG Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

TG aquastat capillary housing provides temperature control for hydronic systems with 1000 mm capillary length and 0/90°C range. Copper and PVC construction with PG 11 connection suits retrofit and new HVAC installations requiring precise setpoint adjustment.

Frequently Asked Questions

What is the TG Aquastat capillary housing 1m internal adjustment 0/90°C used for?

The TG Aquastat capillary housing is used for temperature control in hydronic heating and cooling systems. It is suitable for retrofit and new HVAC installations requiring precise setpoint adjustment, with a 0/90°C range and 1000 mm capillary length.

What are the specifications of the TG Aquastat capillary housing?

The TG Aquastat capillary housing has a temperature range of 0/90°C, capillary length of 1000 mm, bulb dimensions of 73 mm length and 6.5 mm diameter, PG 11 connection, and copper and PVC construction. It features internal adjustment via screwdriver and is rated IP43 or IP55 depending on installation.

Where to buy the TG Aquastat capillary housing in Singapore?

You can source the TG Aquastat capillary housing from 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your location. Contact us for availability and lead time on this TG thermostat model.

How to install the TG Aquastat capillary housing?

Installation should be performed by qualified personnel with power disconnected. Mount the device horizontally or vertically with the cable gland facing downward to ensure IP55 protection. Use heat-resistant cables rated at least T 140. The TG thermostat's internal adjustment allows precise setpoint setting via screwdriver.

Used in

Common applications for TG
Boiler safety limit control — TG safety aquastat (THG70002) with manual reset and fixed 110°C calibration for overheat shutdown in commercial/industrial steam systems
Hydronic heating-system temperature regulation — TG sealed aquastat (THG60010, IP55) with adjustable 0–60°C range and internal adjustment for closed-loop hot-water circuits
Chiller or cooling-loop setpoint control — TG thermostat with external adjustment (THG60008, 0–40°C) for maintaining process or comfort cooling within narrow differentials
Boiler outlet or tank temperature monitoring — TG rectangular thermometer (THG80005, 0–120°C, 3 m capillary) for visual verification of system temperature without electrical integration
Condensate or fluid-level aquastat — TG aquastat with internal adjustment (THG45008, 70–110°C, 1.5 m capillary) for heating-system protection and pump staging in district or building heating plants

TG Products

3G Electric supplies TG thermostats. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Type T thermocouple with pipe connection for temperature measurement in industrial processes, HVAC, and laboratory applications. Accuracy ±1°C. Probe length 22.72 in
ASHCROFT
Type T thermocouple with pipe connection for temperature measurement in industrial processes, HVAC, and laboratory applications. Accuracy ±1°C. Probe length 22.72 in
Type T thermocouple with pipe connection for temperature measurement in industrial processes, HVAC, and laboratory applications. Accuracy ±1°C. Probe length 10.75 inches
ASHCROFT
Type T thermocouple with pipe connection for temperature measurement in industrial processes, HVAC, and laboratory applications. Accuracy ±1°C. Probe length 10.75 inches
Type T thermocouple with pipe connection for temperature measurement in industrial processes, HVAC, refrigeration, and laboratory applications. Features ±1°C accuracy and a 28.74-inch probe length
ASHCROFT
Type T thermocouple with pipe connection for temperature measurement in industrial processes, HVAC, refrigeration, and laboratory applications. Features ±1°C accuracy and a 28.74-inch probe length
Type T thermocouple with pipe connection for temperature measurement in industrial processes, HVAC, refrigeration, and laboratory applications. Accuracy ±1°C, probe length 16.73 inches
ASHCROFT
Type T thermocouple with pipe connection for temperature measurement in industrial processes, HVAC, refrigeration, and laboratory applications. Accuracy ±1°C, probe length 16.73 inches
Type T thermocouple with pipe connection for temperature measurement. Accuracy ±1°C. Probe length 10.75 inches. Suitable for industrial process monitoring, HVAC, refrigeration, and laboratory applications
ASHCROFT
Type T thermocouple with pipe connection for temperature measurement. Accuracy ±1°C. Probe length 10.75 inches. Suitable for industrial process monitoring, HVAC, refrigeration, and laboratory applications
Type T thermocouple with pipe connection for temperature measurement in industrial processes. Accuracy ±1°C. Probe length 10.75 inches. Suitable for monitoring pipelines, storage tanks, and HVAC systems
ASHCROFT
Type T thermocouple with pipe connection for temperature measurement in industrial processes. Accuracy ±1°C. Probe length 10.75 inches. Suitable for monitoring pipelines, storage tanks, and HVAC systems

More from TG

View all TG parts
Double immersion aquastat ext.adj.30-120°C-ext.adj.0-60°C
TG
Double immersion aquastat ext.adj.30-120°C-ext.adj.0-60°C
Security aquastat adjustable int. gold manual actuation 90-110°C capillary 1.5m
TG
Security aquastat adjustable int. gold manual actuation 90-110°C capillary 1.5m
TG
TG
Double immersion aquastat external adj.0-90°C - external adj.30-120°C
TG
TG
Bumper
TG
TG
Square thermometer 0/120°C L1500
TG
TG
Round thermometer 0/120° D57 capillary 1 m
Aquastat capillary case 1m50 external adjustment -35/+35°C
TG
Aquastat capillary case 1m50 external adjustment -35/+35°C
Airstat 9N2.X03 80/120°C
TG
Airstat 9N2.X03 80/120°C