TG Safety aquastat fixed manual reset 110°C capillary 1.5m - Thermostats
TGThermostats

TG Safety aquastat fixed manual reset 110°C capillary 1.5m

TG safety aquastat with fixed manual reset, calibrated to 110°C with 1.5m capillary, delivers 16 A 250V contact rating and adjustable differential of 20-45°C. Designed for boiler and heating system overheat…

SKU 3G-CBM-06930

Also listed as: THG 70002 · THG-70002

Brand
TG
Item
Safety aquastat fixed manual reset 110°C capillary 1.5m
Category
Thermostats
UNSPSC
39122229 — Temperature switch
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

TG
tolerance
+0 -6°C
contacts rating
16 (4) A 250V
capillary length
1.5m
calibration value
110°C
differential manual reset
20-45°C
max sensing element temperature
155°C

Datasheet Content

Caratteristiche tecniche / Technical characteristics Valore di taratura Calibration value 110 °C Tolleranza / tollerance +0 -6 °C Differenziale (riarmo manuale)/differential (manual reset) 2045 °C Temperatura max. di sopportazione dell’elemento sensibile Sensing element max. temperature resistance 155 °C Portata nominole dei contatti C1 16 (4)A 250V ~ Contacts rating C2 contact service Tensione impulsiva nominale / Rated impulsive voltage 2,5 kV Classe di isolamento / Insulation grade ii Temperatura max della testa / Max. head temperature T 120°C Minima temperatura di fonzionamento Minimum working room temperature o°c Elemento sensibile a dilatazione di liquido Liquid filled sensing element Bulbo rame —- Capillare rame ricoperto PVC R3 Copper capillary and bulb — capillary protection with PVC R3 Grado di protezione / Degree of protection IPOO Termostato elettromeccanico incorporato Incorporated electromechanical thermostat Metodo di montaggio : fissaggio a vite / Mounting : screw fixing Messo o terra tramite foston / earthing connection by tab terminal Tipo di azione/Type of action 2B Situazione di inquinamento del dispositivo di comando 2 Pollution level of the control device Utilizzore conduttori resistenti al calore almeno To apply heat resistant conductors of minimum T 130°C Certificazioni Approvals ENEC 03 — C€ 0497 (PED) - DIN Accessori Tappo in materiale plastico nero / Block plastic cap Accessories |Dodo M10x1 esogono ch. 13 / M10x1 nut hexagon key 13 2__|16/11/05|AGGIUNTO-TENSIONE_ IMPULSIVE _E_SITUAZ. INQUINAMENTO . . 1_|19/10/04|AGGIORNATO_TABELLA Z.R. C.F. REV. DATA DESCRIZIONE MODIFICHE DISEGNATO | APPROVATO DESCRIZIONE ‘SCALA LIMITATORE SICUREZZA POSITIVA — RIARMO MANUALE -:- E} LIMITER WITH POSITIVE SAFETY — MANUAL RESET RUGOSITA’ Ro IN micron PRODOTTO. CUENTE DISEGNATO DATA TG400 ZR. 16/02/99 SOSTTUISCE IL STATO PESO GREZZO APPROWRTO me) 02/99 [O00 SR ROE oT TOLER ‘SOSTITUITO DA TRATTAMENTO TERMICO E70 SUPERFICIALE co) DATA MF. 16/02/99 CODICE SEMILAVORATO. T&G SPA Via T. Edison, 2 — 20040 BURAGO M. MILANO |[DISEGNO N. CODICE MATERIA PRIMA 1 presente, caegno # ci propdet® dello TAG SPA @ non pud essere siprodolto in nessun mode na uncle per scan! diversi do Ber PPacoll viens This crowing is property of not used for ony BU 2 19714.11338.00A

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

TG Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

TG safety aquastat with fixed manual reset, calibrated to 110°C with 1.5m capillary, delivers 16 A 250V contact rating and adjustable differential of 20-45°C. Designed for boiler and heating system overheat protection applications.

Frequently Asked Questions

What is a TG safety aquastat fixed manual reset 110°C capillary 1.5m used for?

This TG safety aquastat is used for overheat protection in boilers and heating systems. It provides a fixed manual reset function that locks out the burner if the temperature exceeds the 110°C calibration, preventing unsafe operation until manually reset by an operator.

What are the specifications of the TG safety aquastat 110°C?

The TG safety aquastat has a calibration value of 110°C with a tolerance of +0 -6°C, a manual reset differential of 20-45°C, and a contact rating of 16 (4) A 250V. The capillary length is 1.5m, and the maximum sensing element temperature is 155°C.

Where to buy a TG safety aquastat in Singapore?

You can source the TG safety aquastat from 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this item.

How to install a TG safety aquastat with manual reset?

Mount the aquastat using screw fixing as specified by TG. Ensure the capillary and bulb are positioned to sense the target temperature. Connect heat-resistant conductors rated at least 130°C to the 16 A 250V contacts. After a trip, manually reset the device only after the system has cooled below the reset threshold.

Used in

Common applications for TG
Boiler safety limit control — TG safety aquastat (THG70002) with manual reset and fixed 110°C calibration for overheat shutdown in commercial/industrial steam systems
Hydronic heating-system temperature regulation — TG sealed aquastat (THG60010, IP55) with adjustable 0–60°C range and internal adjustment for closed-loop hot-water circuits
Chiller or cooling-loop setpoint control — TG thermostat with external adjustment (THG60008, 0–40°C) for maintaining process or comfort cooling within narrow differentials
Boiler outlet or tank temperature monitoring — TG rectangular thermometer (THG80005, 0–120°C, 3 m capillary) for visual verification of system temperature without electrical integration
Condensate or fluid-level aquastat — TG aquastat with internal adjustment (THG45008, 70–110°C, 1.5 m capillary) for heating-system protection and pump staging in district or building heating plants

TG Products

3G Electric supplies TG thermostats. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Safety aquastat internal adjustment manual reset 90-110°C capillary 3m
TG
Safety aquastat internal adjustment manual reset 90-110°C capillary 3m
Safety aquastat adj.int.man.70-90°C capillary 1.5m
TG
Safety aquastat adj.int.man.70-90°C capillary 1.5m
Simple immersion aquastat safety with manual reset 100°C
TG
Simple immersion aquastat safety with manual reset 100°C
Safety aquastat internal adjustment manual operation 40-60°C capillary 1m
TG
Safety aquastat internal adjustment manual operation 40-60°C capillary 1m
Aquastat capillary case 1m manual reset 100°C
TG
Aquastat capillary case 1m manual reset 100°C
Safety aquastat int. adj. gold auto 90-110°C capillary 1.5m
TG
Safety aquastat int. adj. gold auto 90-110°C capillary 1.5m

More from TG

View all TG parts
Double immersion aquastat ext.adj.30-120°C-ext.adj.0-60°C
TG
Double immersion aquastat ext.adj.30-120°C-ext.adj.0-60°C
Security aquastat adjustable int. gold manual actuation 90-110°C capillary 1.5m
TG
Security aquastat adjustable int. gold manual actuation 90-110°C capillary 1.5m
TG
TG
Double immersion aquastat external adj.0-90°C - external adj.30-120°C
TG
TG
Bumper
TG
TG
Square thermometer 0/120°C L1500
TG
TG
Round thermometer 0/120° D57 capillary 1 m
Aquastat capillary case 1m50 external adjustment -35/+35°C
TG
Aquastat capillary case 1m50 external adjustment -35/+35°C
Airstat 9N2.X03 80/120°C
TG
Airstat 9N2.X03 80/120°C