Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

TG Security aquastat adjustable int. gold manual actuation 90-110°C capillary 1.5m - Thermostats
TGThermostats

TG Security aquastat adjustable int. gold manual actuation 90-110°C capillary 1.5m

TG security aquastat with manual actuation and adjustable setpoint range of 90–110°C, featuring a 1.5 m capillary for remote temperature sensing in boiler and heating system protection applications.

SKU 3G-CBM-06934

Also listed as: THG 70008 · THG-70008

Brand
TG
Item
Security aquastat adjustable int. gold manual actuation 90-110°C capillary 1.5m
Category
Thermostats
UNSPSC
39122229 — Temperature switch
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

TG
type
Security aquastat
finish
gold
actuation
manual
adjustment range
90-110°C
capillary length
1.5 m

Datasheet Content

M10x1 } fl o 7 | "| TY aN | ° LJ 1 1 1 lo} ef Ky | 2-1 Cc 1 Cc 2 6,3x0,8 13 1500 +50 ~73"Cu” fl 7 2) Il 1 N | E J L- = = —— ee > 5 77 ~~ I | w~ 4) fori_M4 ~2 holes M4 06,5 295 Caratteristiche tecniche / Technical characteristics Campo di regolazione Temperature range 90 + 110 °C Tolleranza / tollerance +0 -6 °C Differenziale (riarmo manuale)/differential (manual reset) 2045 °C Temperatura max. di sopportazione dell’elemento sensibile 135 °C Sensing element max. temperature resistance Conte sting / eountonce Ot C1 100mV === 0,5A /<8 mOhm Classe di isolamento / Insulation grade ll Temperatura max della testa / Max. head temperature T 120°C Minima temperatura di fonzionamento o‘c Minimum working room temperature Elemento sensibile a dilatazione di liquido Liquid filled sensing element Bulbo rame — Capillare rame ricoperto PVC R3 Copper capillary and bulb — capillary protection with PVC R3 Grado di protezione / Degree of protection IPOO Termostato elettromeccanico incorporato Incorporated electromechanical thermostot Metodo di montaggio : fissaggio a vite / Mounting : Messa a terra tramite faston / earthing connection by tab terminal screw fixing Tipo di azione/Type of action 2B Situazione di polluzione/Pollution situation NORMALE /Normol Utilizzare conduttori resistenti al calore almeno T 130°C To apply heat resistant conductors of minimum Certificazioni Approvols ENEC 03 - €€ 0497 (PED) - DIN Accessori Tappo in materiale plastico nero / Black plastic cap Accessories | Dado M10x1 esagono ch. 13 / M10x1 nut hexagon key 13 SCHEMA ELETTRICO Wiring diagram mm 1_|10/10/05[AGGIORNATO TABELLA REV. DATA DESCRIZIONE MODIFICHE DISEGNATO | APPROVATO: DESCRZONE Rory LIMITATORE DORATO SIC. POS. R/MAN 1:1 E LIMITER WITH POS. SAFETY — MANUAL“ RESET PRODOTO CLENTE DSEGRATO DATA TG400 Z.R. [27/01/98 SOSTITUISCE IL ‘STATO PESO GREZZO |APPROVATO. DATA CF. 27/01/98 || OV0TE SENZA OIC. OF TOLLERANZA ‘SOSTITUITO DA TRATTAMENTO TERMICO E/O SUPERFICIALE AQ DATA RM. [27/01/98 CODICE SEMILAVORATO. T&G SPA Via T. Edison, 2 — 20040 BURAGO M. MILANO |[DISEGNO N. CODICE MATERIA PRIMA 1 presente, cisegno @ 3! proprieté dello TAG SPA @ mode na usele per st edo 963.11338.00A

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

TG Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

TG security aquastat with manual actuation and adjustable setpoint range of 90–110°C, featuring a 1.5 m capillary for remote temperature sensing in boiler and heating system protection applications.

Frequently Asked Questions

What is a TG security aquastat used for?

A TG security aquastat is used as a safety limit thermostat in boilers and heating systems. It protects against overheating by manually resetting after a high-temperature trip, with an adjustable setpoint range of 90–110 °C and a 1.5 m capillary for remote sensing.

What are the specifications of the TG security aquastat?

The TG security aquastat has a gold finish, manual actuation, and an adjustable temperature range of 90–110 °C. It features a 1.5 m copper capillary with PVC protection, a differential of 20–45 °C on manual reset, and a maximum sensing element temperature of 135 °C. It carries ENEC and CE (PED) approvals.

Where to buy a TG security aquastat in Singapore?

You can source the TG security aquastat through 3G Electric in Singapore. We handle logistics, customs clearance, and local delivery for this item. Contact our team for pricing and lead time on orders.

How to install a TG security aquastat?

Mount the TG security aquastat using screw fixing with M10x1 nut. Use heat-resistant conductors rated at least T 130 °C. The capillary bulb must be fully immersed in the sensing zone. Ensure manual reset is accessible after installation. Always follow the wiring diagram for correct electrical connections.

Used in

Common applications for TG
Boiler safety limit control — TG safety aquastat (THG70002) with manual reset and fixed 110°C calibration for overheat shutdown in commercial/industrial steam systems
Hydronic heating-system temperature regulation — TG sealed aquastat (THG60010, IP55) with adjustable 0–60°C range and internal adjustment for closed-loop hot-water circuits
Chiller or cooling-loop setpoint control — TG thermostat with external adjustment (THG60008, 0–40°C) for maintaining process or comfort cooling within narrow differentials
Boiler outlet or tank temperature monitoring — TG rectangular thermometer (THG80005, 0–120°C, 3 m capillary) for visual verification of system temperature without electrical integration
Condensate or fluid-level aquastat — TG aquastat with internal adjustment (THG45008, 70–110°C, 1.5 m capillary) for heating-system protection and pump staging in district or building heating plants

TG Products

3G Electric supplies TG thermostats. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Safety aquastat int. adj. gold auto 90-110°C capillary 1.5m
TG
Safety aquastat int. adj. gold auto 90-110°C capillary 1.5m
Safety aquastat adj.int.man.70-90°C capillary 1.5m
TG
Safety aquastat adj.int.man.70-90°C capillary 1.5m
Safety aquastat internal adjustment manual reset 90-110°C capillary 3m
TG
Safety aquastat internal adjustment manual reset 90-110°C capillary 3m
Safety aquastat fixed manual reset 110°C capillary 1.5m
TG
Safety aquastat fixed manual reset 110°C capillary 1.5m
Safety aquastat internal adjustment manual operation 40-60°C capillary 1m
TG
Safety aquastat internal adjustment manual operation 40-60°C capillary 1m
Aquastat internal adjustment 0-90°C capillary 1.5m
TG
Aquastat internal adjustment 0-90°C capillary 1.5m

More from TG

View all TG parts
Double immersion aquastat ext.adj.30-120°C-ext.adj.0-60°C
TG
Double immersion aquastat ext.adj.30-120°C-ext.adj.0-60°C
TG
TG
Double immersion aquastat external adj.0-90°C - external adj.30-120°C
TG
TG
Bumper
TG
TG
Square thermometer 0/120°C L1500
TG
TG
Round thermometer 0/120° D57 capillary 1 m
Aquastat capillary case 1m50 external adjustment -35/+35°C
TG
Aquastat capillary case 1m50 external adjustment -35/+35°C
Airstat 9N2.X03 80/120°C
TG
Airstat 9N2.X03 80/120°C
Sealed thermostat external adjustment 0-40°C
TG
Sealed thermostat external adjustment 0-40°C