Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Dayton Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity - IEC Thermal Overload Relays
DaytonIEC Thermal Overload Relays

Dayton Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity

The DAYTON Overload Relay (MPN 6ECC7) is a 3-pole IEC thermal overload relay with integrated bimetallic elements, eliminating the need for separate thermal units. It features 1NO/1NC auxiliary contacts and phase loss…

SKU 3G-OTH-40898

Brand
Dayton
Item
Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity
Category
IEC Thermal Overload Relays
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

Dayton
Manufacturer Part Number
6ECC7
Type
1NO/1NC, Phase Loss Sensitivity, 23 A – 32 A
Poles
3
Compatible Contactors
Dayton (25 to 32 Amps Models)
Auxiliary Contact Form
1NO/1NC
Phase Loss Sensitivity
Yes
Thermal Units Required
None (Relay Includes Integrated Bimetallic Elements)
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dayton Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DAYTON Overload Relay (MPN 6ECC7) is a 3-pole IEC thermal overload relay with integrated bimetallic elements, eliminating the need for separate thermal units. It features 1NO/1NC auxiliary contacts and phase loss sensitivity, and is compatible with Dayton contactors rated 25 to 32 Amps. The relay provides thermal protection for motors within a 23 A to 32 A adjustment range.

Frequently Asked Questions

What is the DAYTON Overload Relay 6ECC7 used for?

The DAYTON Overload Relay 6ECC7 provides thermal protection for three-phase motors by monitoring current and tripping on overload or phase loss. It is used in industrial motor control panels, conveyors, pumps, and HVAC equipment to prevent motor damage from sustained overcurrent or unbalanced supply.

What are the specifications of the DAYTON Overload Relay 6ECC7?

The DAYTON Overload Relay 6ECC7 is a 3-pole IEC thermal overload relay with integrated bimetallic elements, eliminating separate thermal units. It has 1NO/1NC auxiliary contacts, phase loss sensitivity, and an adjustment range of 23 A to 32 A. It is compatible with Dayton contactors rated 25 to 32 Amps.

Where to buy the DAYTON Overload Relay 6ECC7 worldwide?

3G Electric supplies the DAYTON Overload Relay 6ECC7 to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this thermal overload relay.

How to select the correct overload relay for a motor?

Select an overload relay with an adjustment range that covers the motor's full-load current rating. For the DAYTON Overload Relay 6ECC7, set the dial between 23 A and 32 A to match the motor nameplate. Ensure the relay is compatible with your contactor and includes phase loss sensitivity for unbalanced supply protection.

Used in

Common applications for Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Products

3G Electric supplies Dayton iec thermal overload relays. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 17 A – 25 A (MPN 6ECC6). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (25 to 32 Amps Models).
Dayton
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 17 A – 25 A (MPN 6ECC6). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (25 to 32 Amps Models).
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 7 A – 10 A (MPN 6ECC3). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).
Dayton
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 7 A – 10 A (MPN 6ECC3). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 9 A – 13 A (MPN 6ECC4). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).
Dayton
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 9 A – 13 A (MPN 6ECC4). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 28 A – 36 A (MPN 6ECC8). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (25 to 32 Amps Models).
Dayton
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 28 A – 36 A (MPN 6ECC8). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (25 to 32 Amps Models).
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 2.5 A – 4 A (MPN 6ECC0). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).
Dayton
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 2.5 A – 4 A (MPN 6ECC0). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 12 A – 18 A (MPN 6ECC5). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).
Dayton
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 12 A – 18 A (MPN 6ECC5). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).

More from Dayton

View all Dayton parts
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 48 A – 65 A (MPN 6ECA0). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (40 to 95 Amp Models).
Dayton
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 48 A – 65 A (MPN 6ECA0). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (40 to 95 Amp Models).
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 55 A – 70 A (MPN 6ECA1). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (40 to 95 Amp Models).
Dayton
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 55 A – 70 A (MPN 6ECA1). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (40 to 95 Amp Models).
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 5.5 A – 8 A (MPN 6ECC2). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).
Dayton
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 5.5 A – 8 A (MPN 6ECC2). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 0.16 A – 0.25 A (MPN 6ECA4). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).
Dayton
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 0.16 A – 0.25 A (MPN 6ECA4). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 23 A – 32 A (MPN 6EAZ7). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (40 to 95 Amp Models).
Dayton
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 23 A – 32 A (MPN 6EAZ7). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (40 to 95 Amp Models).
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 0.1 A – 0.16 A (MPN 6ECA3). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).
Dayton
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 0.1 A – 0.16 A (MPN 6ECA3). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 1.6 A – 2.5 A (MPN 6ECA9). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).
Dayton
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 1.6 A – 2.5 A (MPN 6ECA9). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (9 to 18 Amp Models).
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 37 A – 50 A (MPN 6EAZ9). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (40 to 95 Amp Models).
Dayton
DAYTON Overload Relay: Thermal Protection, 3 Poles, 1NO/1NC, Phase Loss Sensitivity, 37 A – 50 A (MPN 6EAZ9). Key specifications — Brand: DAYTON; Auxiliary Contact Form: 1NO/1NC; Phase Loss Sensitivity: Yes; Thermal Units Required: None (Relay Includes Integrated Bimetallic Elements); Compatible Contactors: Dayton (40 to 95 Amp Models).