The DRAEGER Detector Tube for Accuro pumps is a carbon dioxide (CO2) gas detection tube, supplied in a 10-pack (MPN 6728521). It measures CO2 concentrations from 100 to 3,000 ppm, designed for use with DRAEGER Accuro…

SKU 3G-OTH-548074

Brand
DRAEGER
Item
Carbon Dioxide Gas Detection Tube for Accuro Pumps
Part Number
6728521
Category
Gas Detection Tubes For Use In DRAEGER Accuro Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.

Compliance & shipping

Hazardous material
Not classified as hazardous
California Prop 65 warning
Warning appliesWARNING Cancer - www.P65Warnings.ca.gov
Licence required
No licence required
Safety Data Sheet
Not available
Special shipping
Ships under standard freight

Technical Specifications

DRAEGER
Manufacturer Part Number
6728521
Type
CO2, Gas Detection Tube, Carbon Dioxide ( CO2 ), 10 PK
UNSPSC
41113116
Weight
1 lbs
Includes
Instructions
Pressure
Only use the Draeger Carbon Dioxide Detector Tube for depressurized compressed air
Flow Rate
0,2
CAS Number
124-38-9
Calibrated
Yes
Dimensions
7 × 2 × 2 in
Shelf Life
2 yr
Temperature
15 to 25
Test Volume
1
Catalog Page
N/A
Color Change
White to Violet
Gas Detected
Carbon Dioxide
Product Type
Gas Detection Tube
Break-Off Tip
Yes
Sampling Time
5 min (100 to 3,000 ppm)
Tube Material
Glass
Sampling Volume
1,000 mL
Absolute Humidity
max. 23
Country of Origin
Germany (subject to change)
Cross Sensitivity
This Draeger CO2 Detector Tube does not indicate hydrogen sulfide and sulfur dioxide in the TLV range.
Measurement Range
100 to 3,000 ppm
Operating Pressure
1,013 hPa
Standard Deviation
± 10 to 15
Time for Measurement
approx. 5
Operating Temperature
59 °F to 77 °F
Standard Measuring Range
100 to 3,000
Maximum Operating Temperature
77 °F
Minimum Operating Temperature
59 °F

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Ask a question

Request a Quote

Ask a question

DRAEGER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DRAEGER Detector Tube for Accuro pumps is a carbon dioxide (CO2) gas detection tube, supplied in a 10-pack (MPN 6728521). It measures CO2 concentrations from 100 to 3,000 ppm, designed for use with DRAEGER Accuro pumps.

Frequently Asked Questions

What is the DRAEGER Detector Tube 6728521 used for?

The DRAEGER Detector Tube 6728521 is used for measuring carbon dioxide (CO2) concentrations in industrial environments. It works with DRAEGER Accuro pumps to detect CO2 levels from 100 to 3,000 ppm, supporting safety monitoring in confined spaces, HVAC, and combustion applications.

What are the specifications of the DRAEGER CO2 detector tube 6728521?

The DRAEGER CO2 detector tube (MPN 6728521) detects carbon dioxide with a measurement range of 100 to 3,000 ppm. It is supplied in a 10-pack and is designed for use with DRAEGER Accuro pumps. Each tube provides a single-use colorimetric reading for spot-check gas analysis.

Where to buy DRAEGER Accuro CO2 detector tubes worldwide?

3G Electric supplies DRAEGER Accuro CO2 detector tubes (MPN 6728521) worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this 10-pack of carbon dioxide detection tubes.

How to use DRAEGER Accuro tubes for CO2 detection?

To use DRAEGER Accuro tubes for CO2 detection, break off both tips of the tube, insert it into the Accuro pump, and pull the handle to draw a sample. Read the color change against the printed scale. Follow the pump manufacturer’s instructions for accurate results between 100 and 3,000 ppm.

Not sure this is the right part? Photo-identify it→

DRAEGER Products

3G Electric supplies DRAEGER gas detection tubes for use in draeger accuro pumps. We supply genuine products and their technical documentation.

You might also need

Pump Accessories →Valves & Regulation →Motors & Drives →All Products →

More from DRAEGER

View all DRAEGER parts →
Gas detection tube for use with DRAEGER Accuro pumps. Detects ethylene (C2H4) in a measurement range of 0.2 to 5 ppm. Supplied in a pack of 10 tubes. Suitable for spot-checking ethylene concentrations in industrial environments such as chemical processing or refrigeration
DRAEGER
Gas detection tube for use with DRAEGER Accuro pumps. Detects ethylene (C2H4) in a measurement range of 0.2 to 5 ppm. Supplied in a pack of 10 tubes. Suitable for spot-checking ethylene concentrations in industrial environments such as chemical processing or refrigeration
Gas detection tube for use with DRAEGER Accuro pumps. Detects oil mist in the range of 1 to 10 mg/m3. Maximum operating temperature 86°F. Pack of 10 tubes. Suitable for industrial air monitoring in environments where oil mist may be present
DRAEGER
Gas detection tube for use with DRAEGER Accuro pumps. Detects oil mist in the range of 1 to 10 mg/m3. Maximum operating temperature 86°F. Pack of 10 tubes. Suitable for industrial air monitoring in environments where oil mist may be present
Gas detection tube for use with DRAEGER Accuro pumps. Detects methylene chloride (CH2Cl2) in air over a measurement range of 20 to 200 ppm. Maximum operating temperature 86°F. Pack of 10 tubes. Suitable for spot-checking airborne solvent concentrations in industrial environments
DRAEGER
Gas detection tube for use with DRAEGER Accuro pumps. Detects methylene chloride (CH2Cl2) in air over a measurement range of 20 to 200 ppm. Maximum operating temperature 86°F. Pack of 10 tubes. Suitable for spot-checking airborne solvent concentrations in industrial environments
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps. Each tube detects diethyl ether ((C2H5)2O) within a measurement range of 100 to 4,000 ppm and operates at temperatures up to 104°F. Suitable for industrial safety monitoring where diethyl ether may be present
DRAEGER
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps. Each tube detects diethyl ether ((C2H5)2O) within a measurement range of 100 to 4,000 ppm and operates at temperatures up to 104°F. Suitable for industrial safety monitoring where diethyl ether may be present
Gas detection tube for use with DRAEGER Accuro pumps. Detects hydrochloric acid (HCl) in the range of 1 to 10 ppm. Supplied in a pack of 10 tubes. Suitable for on-the-spot measurement of HCl concentrations in industrial environments
DRAEGER
Gas detection tube for use with DRAEGER Accuro pumps. Detects hydrochloric acid (HCl) in the range of 1 to 10 ppm. Supplied in a pack of 10 tubes. Suitable for on-the-spot measurement of HCl concentrations in industrial environments
DRAEGER CS2 gas detection tube for use with Accuro pumps. Detects carbon disulfide (CS2) in the range of 3 to 95 ppm. Pack of 10 tubes. Suitable for industrial safety monitoring in environments where carbon disulfide may be present
DRAEGER
DRAEGER CS2 gas detection tube for use with Accuro pumps. Detects carbon disulfide (CS2) in the range of 3 to 95 ppm. Pack of 10 tubes. Suitable for industrial safety monitoring in environments where carbon disulfide may be present
Qualitative gas detection tube for use with DRAEGER Accuro pumps. Detects Hydrogen Acid with a 3-minute measurement time. Maximum operating temperature 86°F. Supplied in a 10-pack
DRAEGER
Qualitative gas detection tube for use with DRAEGER Accuro pumps. Detects Hydrogen Acid with a 3-minute measurement time. Maximum operating temperature 86°F. Supplied in a 10-pack
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps to measure hydrogen sulfide (H2S) concentrations in ambient air. Each tube provides a colorimetric indication over a measurement range of 2 to 60 ppm. Typical applications include monitoring toxic gas exposure in industrial environments such as refineries, chemical plants, and confined spaces
DRAEGER
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps to measure hydrogen sulfide (H2S) concentrations in ambient air. Each tube provides a colorimetric indication over a measurement range of 2 to 60 ppm. Typical applications include monitoring toxic gas exposure in industrial environments such as refineries, chemical plants, and confined spaces

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first