DRAEGER CH2O Gas Detection Tube for Accuro Pumps, 10-Pack - Gas Detection Tubes For Use In DRAEGER Accuro Pumps
DRAEGERGas Detection Tubes For Use In DRAEGER Accuro Pumps

DRAEGER CH2O Gas Detection Tube for Accuro Pumps, 10-Pack

The DRAEGER Detector Tube for Accuro pumps is a CH2O gas detection tube designed to detect formaldehyde (CH2O) across three measurement ranges: 0.04 to 0.5 ppm, 0.05 to 0.63 ppm, and 0.1 to 1.25 ppm. Supplied in a…

SKU 3G-OTH-548683

Brand
DRAEGER
Item
CH2O Gas Detection Tube for Accuro Pumps, 10-Pack
Category
Gas Detection Tubes For Use In DRAEGER Accuro Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

DRAEGER
Manufacturer Part Number
8101141
Type
CH2O, Gas Detection Tube, Formaldehyde ( CH2O ), 10 PK
Gas Detected
Formaldehyde
Measurement Range
0.04 to 0.5 ppm/0.05 to 0.63 ppm/0.1 to 1.25 ppm

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DRAEGER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DRAEGER Detector Tube for Accuro pumps is a CH2O gas detection tube designed to detect formaldehyde (CH2O) across three measurement ranges: 0.04 to 0.5 ppm, 0.05 to 0.63 ppm, and 0.1 to 1.25 ppm. Supplied in a 10-pack (MPN 8101141), this OEM tube is purpose-built for use with DRAEGER Accuro pumps, enabling precise spot-check sampling of airborne formaldehyde concentrations.

Frequently Asked Questions

What is the DRAEGER Accuro CH2O detector tube used for?

The DRAEGER Accuro CH2O detector tube (MPN 8101141) is used for spot-check sampling of airborne formaldehyde concentrations in industrial environments. It works with DRAEGER Accuro pumps to measure formaldehyde across three ranges: 0.04 to 0.5 ppm, 0.05 to 0.63 ppm, and 0.1 to 1.25 ppm.

What are the specifications of the DRAEGER Accuro CH2O gas detection tube?

The DRAEGER Accuro CH2O gas detection tube detects formaldehyde (CH2O) with measurement ranges of 0.04 to 0.5 ppm, 0.05 to 0.63 ppm, and 0.1 to 1.25 ppm. It is supplied in a 10-pack with manufacturer part number 8101141 and is designed exclusively for use with DRAEGER Accuro pumps.

Where to buy DRAEGER Accuro CH2O detector tubes worldwide?

3G Electric supplies DRAEGER Accuro CH2O detector tubes (MPN 8101141) worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us to order this 10-pack of formaldehyde detection tubes for your Accuro pump.

How to use the DRAEGER Accuro CH2O detector tube with an Accuro pump?

To use the DRAEGER Accuro CH2O detector tube, break off both tips of the tube, insert it into the DRAEGER Accuro pump, and follow the pump's stroke count for the desired measurement range. After sampling, read the color change against the printed scale. Always refer to the manufacturer's instructions for safe operation.

DRAEGER Products

3G Electric supplies DRAEGER gas detection tubes for use in draeger accuro pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from DRAEGER

View all DRAEGER parts
This gas detection tube is designed for use with DRAEGER Accuro pumps to measure hydrogen sulfide (H2S) concentrations in the range of 100 to 2,000 ppm. Each pack contains 10 tubes, enabling field detection of H2S in industrial environments such as oil and gas, chemical processing, and wastewater treatment
DRAEGER
This gas detection tube is designed for use with DRAEGER Accuro pumps to measure hydrogen sulfide (H2S) concentrations in the range of 100 to 2,000 ppm. Each pack contains 10 tubes, enabling field detection of H2S in industrial environments such as oil and gas, chemical processing, and wastewater treatment
This gas detection tube is designed to measure water vapor (H2O) concentrations in the range of 5 to 250 mg/m3. It is intended for use with DRAEGER Accuro pumps to monitor moisture levels in process gases or compressed air systems. Supplied in a pack of 10
DRAEGER
This gas detection tube is designed to measure water vapor (H2O) concentrations in the range of 5 to 250 mg/m3. It is intended for use with DRAEGER Accuro pumps to monitor moisture levels in process gases or compressed air systems. Supplied in a pack of 10
Gas detection tube for measuring phenol (C6H5OH) concentrations in air. Designed for use with DRAEGER Accuro pumps. Measurement range: 1 to 20 ppm. Supplied as a pack of 10 tubes. Suitable for industrial hygiene and safety monitoring in environments where phenol may be present
DRAEGER
Gas detection tube for measuring phenol (C6H5OH) concentrations in air. Designed for use with DRAEGER Accuro pumps. Measurement range: 1 to 20 ppm. Supplied as a pack of 10 tubes. Suitable for industrial hygiene and safety monitoring in environments where phenol may be present
This gas detection tube is designed for use with DRAEGER Accuro pumps to measure acetaldehyde (C2H4O) concentrations in the range of 100 to 1,000 ppm. Supplied in packs of 10, it enables on-site detection of acetaldehyde in industrial environments where exposure monitoring is required
DRAEGER
This gas detection tube is designed for use with DRAEGER Accuro pumps to measure acetaldehyde (C2H4O) concentrations in the range of 100 to 1,000 ppm. Supplied in packs of 10, it enables on-site detection of acetaldehyde in industrial environments where exposure monitoring is required
Gas detection tube for hexane (C6H14) used with DRAEGER Accuro pumps. Measures concentrations from 10 to 200 ppm and 300 to 2,500 ppm. Supplied in a 10-pack. Suitable for industrial hygiene and safety monitoring in environments where hexane vapors may be present
DRAEGER
Gas detection tube for hexane (C6H14) used with DRAEGER Accuro pumps. Measures concentrations from 10 to 200 ppm and 300 to 2,500 ppm. Supplied in a 10-pack. Suitable for industrial hygiene and safety monitoring in environments where hexane vapors may be present
Carbon disulfide (CS2) detector tube for use with DRAEGER Accuro pumps. Measurement range: 0.1 to 10 mg/L. Supplied in a pack of 10. Suitable for spot-check sampling in industrial hygiene and chemical processing environments
DRAEGER
Carbon disulfide (CS2) detector tube for use with DRAEGER Accuro pumps. Measurement range: 0.1 to 10 mg/L. Supplied in a pack of 10. Suitable for spot-check sampling in industrial hygiene and chemical processing environments
Gas detection tube for spot-check sampling of pentane (C5H12) in air. Measures concentrations from 100 to 1,500 ppm. Designed for use with DRAEGER Accuro pumps. Supplied in packs of 10 tubes
DRAEGER
Gas detection tube for spot-check sampling of pentane (C5H12) in air. Measures concentrations from 100 to 1,500 ppm. Designed for use with DRAEGER Accuro pumps. Supplied in packs of 10 tubes
This gas detection tube is designed for use with DRAEGER Accuro pumps to measure sulfur dioxide (SO2) concentrations in the range of 0.1 to 3 ppm. Each pack contains 10 tubes, suitable for spot-check sampling in industrial environments where SO2 exposure monitoring is required
DRAEGER
This gas detection tube is designed for use with DRAEGER Accuro pumps to measure sulfur dioxide (SO2) concentrations in the range of 0.1 to 3 ppm. Each pack contains 10 tubes, suitable for spot-check sampling in industrial environments where SO2 exposure monitoring is required