Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

DRAEGER Gas Detection Tube for Accuro Pumps, Oil, 10-Pack (8103111) - Gas Detection Tubes For Use In DRAEGER Accuro Pumps
DRAEGERGas Detection Tubes For Use In DRAEGER Accuro Pumps

DRAEGER Gas Detection Tube for Accuro Pumps, Oil, 10-Pack (8103111)

The DRAEGER Detector Tube for DRAEGER Accuro pumps is a gas detection tube designed for occupational health and safety applications, detecting oil. Supplied in a pack of 10 (MPN 8103111), this tube is used…

SKU 3G-OTH-548137

Brand
DRAEGER
Item
Gas Detection Tube for Accuro Pumps, Oil, 10-Pack
Category
Gas Detection Tubes For Use In DRAEGER Accuro Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

DRAEGER
Manufacturer Part Number
8103111
Type
Gas Detection Tube, Oil, Occupational Heath & Safety, 10 PK
Gas Detected
Oil

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DRAEGER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DRAEGER Detector Tube for DRAEGER Accuro pumps is a gas detection tube designed for occupational health and safety applications, detecting oil. Supplied in a pack of 10 (MPN 8103111), this tube is used exclusively with DRAEGER Accuro pumps for reliable gas sampling.

Frequently Asked Questions

What is the DRAEGER Detector Tube 8103111 used for?

The DRAEGER Detector Tube 8103111 is used for detecting oil in air samples during occupational health and safety monitoring. It is designed exclusively for use with DRAEGER Accuro pumps to provide reliable gas sampling in industrial environments.

What are the specifications of the DRAEGER Detector Tube 8103111?

The DRAEGER Detector Tube 8103111 detects oil and is supplied in a pack of 10. It is designed for use with DRAEGER Accuro pumps. The manufacturer part number is 8103111, and it is intended for occupational health and safety applications.

Where to buy DRAEGER Detector Tube 8103111 worldwide?

3G Electric supplies the DRAEGER Detector Tube 8103111 worldwide. As a global industrial solutions provider, we handle logistics, customs, and delivery to ensure you receive genuine DRAEGER gas detection tubes for your Accuro pump.

How to use the DRAEGER Detector Tube 8103111 with an Accuro pump?

To use the DRAEGER Detector Tube 8103111, break off both tips of the tube, insert it into the DRAEGER Accuro pump, and follow the pump’s sampling procedure. Refer to the pump manual for correct stroke count and timing to ensure accurate oil detection.

DRAEGER Products

3G Electric supplies DRAEGER gas detection tubes for use in draeger accuro pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from DRAEGER

View all DRAEGER parts
This gas detection tube is designed for use with DRAEGER Accuro pumps to measure sulfur dioxide (SO2) concentrations in the range of 0.1 to 3 ppm. Each pack contains 10 tubes, suitable for spot-check sampling in industrial environments where SO2 exposure monitoring is required
DRAEGER
This gas detection tube is designed for use with DRAEGER Accuro pumps to measure sulfur dioxide (SO2) concentrations in the range of 0.1 to 3 ppm. Each pack contains 10 tubes, suitable for spot-check sampling in industrial environments where SO2 exposure monitoring is required
Gas detection tube for nitric acid (HNO3) designed for use with DRAEGER Accuro pumps. Measures concentrations in ranges of 5 to 50 ppm and 1 to 15 ppm. Supplied as a 10-pack for single-use colorimetric detection in industrial air monitoring
DRAEGER
Gas detection tube for nitric acid (HNO3) designed for use with DRAEGER Accuro pumps. Measures concentrations in ranges of 5 to 50 ppm and 1 to 15 ppm. Supplied as a 10-pack for single-use colorimetric detection in industrial air monitoring
Oxygen (O2) gas detection tube for use with DRAEGER Accuro pumps. Measures oxygen concentrations from 5 to 23% vol. Supplied as a 10-pack with instructions. Provides direct-read colorimetric results for field analysis
DRAEGER
Oxygen (O2) gas detection tube for use with DRAEGER Accuro pumps. Measures oxygen concentrations from 5 to 23% vol. Supplied as a 10-pack with instructions. Provides direct-read colorimetric results for field analysis
This hydrogen sulfide (H2S) gas detection tube is designed for use with DRAEGER Accuro pumps. It measures H2S concentrations from 2 to 40% vol. Sold in packs of 10, it is used for spot-check measurements in industrial environments such as oil and gas, chemical processing, and wastewater treatment
DRAEGER
This hydrogen sulfide (H2S) gas detection tube is designed for use with DRAEGER Accuro pumps. It measures H2S concentrations from 2 to 40% vol. Sold in packs of 10, it is used for spot-check measurements in industrial environments such as oil and gas, chemical processing, and wastewater treatment
DRAEGER CH20301 detector tube for carbon dioxide (CO2) measurement in the range of 5 to 60% vol. Supplied in a 10-pack for use with DRAEGER Accuro bellows pumps. Provides direct-reading colorimetric indication for workplace safety, confined-space entry, and process monitoring
DRAEGER
DRAEGER CH20301 detector tube for carbon dioxide (CO2) measurement in the range of 5 to 60% vol. Supplied in a 10-pack for use with DRAEGER Accuro bellows pumps. Provides direct-reading colorimetric indication for workplace safety, confined-space entry, and process monitoring
Sulfur dioxide (SO2) gas detection tube for use with DRAEGER Accuro pumps. Measures SO2 in two ranges: 400 to 8,000 ppm and 50 to 500 ppm. Pack of 10 tubes for on-site gas analysis in industrial safety applications
DRAEGER
Sulfur dioxide (SO2) gas detection tube for use with DRAEGER Accuro pumps. Measures SO2 in two ranges: 400 to 8,000 ppm and 50 to 500 ppm. Pack of 10 tubes for on-site gas analysis in industrial safety applications
This gas detection tube is designed for use with DRAEGER Accuro pumps to measure ammonia (NH3) concentrations in the range of 0.5 to 10% by volume. Each pack contains 10 tubes for multiple tests. The tube provides direct-reading results, enabling quick assessment of ammonia levels in industrial environments such as refrigeration or chemical processing areas
DRAEGER
This gas detection tube is designed for use with DRAEGER Accuro pumps to measure ammonia (NH3) concentrations in the range of 0.5 to 10% by volume. Each pack contains 10 tubes for multiple tests. The tube provides direct-reading results, enabling quick assessment of ammonia levels in industrial environments such as refrigeration or chemical processing areas
This pack of 5 gas detection tubes is designed for use with DRAEGER Accuro pumps. Each tube detects carbon monoxide (CO) in natural gas for qualitative measurement. Sampling time is 100 seconds. Typical applications include spot-checking for CO presence in natural gas systems
DRAEGER
This pack of 5 gas detection tubes is designed for use with DRAEGER Accuro pumps. Each tube detects carbon monoxide (CO) in natural gas for qualitative measurement. Sampling time is 100 seconds. Typical applications include spot-checking for CO presence in natural gas systems