Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

DRAEGER Detector Tube: DRAEGER Accuro, N2H4, Gas Detection Tube, Hydrazine ( N2H4) - Gas Detection Tubes For Use In DRAEGER Accuro Pumps
DRAEGERGas Detection Tubes For Use In DRAEGER Accuro Pumps

DRAEGER Detector Tube: DRAEGER Accuro, N2H4, Gas Detection Tube, Hydrazine ( N2H4)

The DRAEGER Accuro Gas Detection Tube (MPN 8103351) detects hydrazine (N2H4) with a measurement range of 0.01 to 0.4 ppm and 0.5 to 6 ppm, supplied in a 10-pack for use with DRAEGER Accuro pumps. 3G Electric…

SKU 3G-OTH-548103

Brand
DRAEGER
Item
Detector Tube: DRAEGER Accuro, N2H4, Gas Detection Tube, Hydrazine
Category
Gas Detection Tubes For Use In DRAEGER Accuro Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

DRAEGER
Manufacturer Part Number
8103351
Type
N2H4, Gas Detection Tube, Hydrazine ( N2H4 ), 10 PK
Gas Detected
Hydrazine
Measurement Range
0.01 to 0.4 ppm/0.5 to 6 ppm

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DRAEGER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DRAEGER Accuro Gas Detection Tube (MPN 8103351) detects hydrazine (N2H4) with a measurement range of 0.01 to 0.4 ppm and 0.5 to 6 ppm, supplied in a 10-pack for use with DRAEGER Accuro pumps. 3G Electric interprets this demand and delivers genuine industrial equipment across 14 departments—and far more—with specialist depth in combustion, pumps and controls as an authorised distributor for brands like Schneider, ABB, Siemens, SKF, Festo, Fluke, Interpump and FBR.

Frequently Asked Questions

What is the DRAEGER Accuro gas detection tube 8103351 used for?

The DRAEGER Accuro tube 8103351 detects hydrazine (N2H4) in workplace air, with a measurement range of 0.01 to 0.4 ppm and 0.5 to 6 ppm. It is used for industrial hygiene, chemical processing, and aerospace applications where hydrazine exposure monitoring is required.

What are the specifications of the DRAEGER Accuro hydrazine detector tube?

The DRAEGER Accuro tube (MPN 8103351) detects hydrazine (N2H4) with two measurement ranges: 0.01 to 0.4 ppm and 0.5 to 6 ppm. It is supplied in a 10-pack and designed for use with DRAEGER Accuro pumps.

Where to buy DRAEGER Accuro gas detection tubes worldwide?

3G Electric supplies genuine DRAEGER Accuro gas detection tubes worldwide. We handle full logistics, customs clearance, and delivery to your site. As a global industrial solutions provider, we source across 14 departments—including combustion, pumps, and controls—and deliver to any location.

How to use the DRAEGER Accuro tube for hydrazine detection?

Insert the DRAEGER Accuro tube into the Accuro pump, break off both tips, and draw the specified number of pump strokes per the tube instructions. Read the stain length against the printed scale. Always follow the manufacturer's safety guidelines for hydrazine handling.

DRAEGER Products

3G Electric supplies DRAEGER gas detection tubes for use in draeger accuro pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from DRAEGER

View all DRAEGER parts
Gas detection tube for use with DRAEGER Accuro pumps. Detects chlorodioxide (ClO2) with a measurement range of 0.1 to 1 ppm or 0.025 to 0.1 ppm. Supplied in a pack of 10. Suitable for spot-check sampling of chlorodioxide concentrations in industrial environments
DRAEGER
Gas detection tube for use with DRAEGER Accuro pumps. Detects chlorodioxide (ClO2) with a measurement range of 0.1 to 1 ppm or 0.025 to 0.1 ppm. Supplied in a pack of 10. Suitable for spot-check sampling of chlorodioxide concentrations in industrial environments
Gas detection tube for hydrochloric acid (HCl) vapor. Two measurement ranges: 0.2 to 3 ppm and 3 to 20 ppm. For use with DRAEGER Accuro pumps. Pack of 10 tubes
DRAEGER
Gas detection tube for hydrochloric acid (HCl) vapor. Two measurement ranges: 0.2 to 3 ppm and 3 to 20 ppm. For use with DRAEGER Accuro pumps. Pack of 10 tubes
Gas detection tube for ozone (O3) with a measurement range of 20 to 300 ppm. Designed for use with DRAEGER Accuro pumps. Pack of 10 tubes. Suitable for industrial hygiene and workplace safety monitoring where ozone exposure may occur
DRAEGER
Gas detection tube for ozone (O3) with a measurement range of 20 to 300 ppm. Designed for use with DRAEGER Accuro pumps. Pack of 10 tubes. Suitable for industrial hygiene and workplace safety monitoring where ozone exposure may occur
Gas detection tube for ammonia (NH3) monitoring with DRAEGER Accuro pumps. Measures ammonia across two ranges: 5 to 70 ppm and 50 to 600 ppm. Supplied in a 10-pack with instructions. Used for industrial safety checks in environments where ammonia may be present
DRAEGER
Gas detection tube for ammonia (NH3) monitoring with DRAEGER Accuro pumps. Measures ammonia across two ranges: 5 to 70 ppm and 50 to 600 ppm. Supplied in a 10-pack with instructions. Used for industrial safety checks in environments where ammonia may be present
DRAEGER CH31201 gas detection tube for use with DRAEGER Accuro pumps. Detects olefine (CNH2N) including propylene and butylene. Measurement range: 0.06 to 3.2% vol (propylene) and 0.04 to 2.4% vol (butylene). Pack of 10 tubes for spot-check monitoring in industrial environments where unsaturated hydrocarbons may be present
DRAEGER
DRAEGER CH31201 gas detection tube for use with DRAEGER Accuro pumps. Detects olefine (CNH2N) including propylene and butylene. Measurement range: 0.06 to 3.2% vol (propylene) and 0.04 to 2.4% vol (butylene). Pack of 10 tubes for spot-check monitoring in industrial environments where unsaturated hydrocarbons may be present
Formaldehyde (CH2O) detection tube for use with DRAEGER Accuro pumps. Measures airborne formaldehyde concentrations across three ranges: 0.04 to 0.5 ppm, 0.05 to 0.63 ppm, and 0.1 to 1.25 ppm. Supplied in a 10-pack. Suitable for spot-check sampling in industrial environments
DRAEGER
Formaldehyde (CH2O) detection tube for use with DRAEGER Accuro pumps. Measures airborne formaldehyde concentrations across three ranges: 0.04 to 0.5 ppm, 0.05 to 0.63 ppm, and 0.1 to 1.25 ppm. Supplied in a 10-pack. Suitable for spot-check sampling in industrial environments
Qualitative gas detection tube for use with DRAEGER Accuro pumps. Detects Polytest gases with a maximum operating temperature of 122°F. Suitable for on-site identification in industrial safety monitoring applications such as confined space entry and leak detection
DRAEGER
Qualitative gas detection tube for use with DRAEGER Accuro pumps. Detects Polytest gases with a maximum operating temperature of 122°F. Suitable for on-site identification in industrial safety monitoring applications such as confined space entry and leak detection
This gas detection tube is designed for use with DRAEGER Accuro pumps to measure cyanide (CN-) concentrations in air. The measurement range is 2 to 15 mg/m³. Each pack contains 10 tubes with instructions. Typical applications include industrial hygiene monitoring in environments where cyanide exposure may occur
DRAEGER
This gas detection tube is designed for use with DRAEGER Accuro pumps to measure cyanide (CN-) concentrations in air. The measurement range is 2 to 15 mg/m³. Each pack contains 10 tubes with instructions. Typical applications include industrial hygiene monitoring in environments where cyanide exposure may occur