Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

DUNGS AA-A2 - Pressure Switches for air, flue and exhaust gases (US/CA)
DungsPressure switch

DUNGS AA-A2 - Pressure Switches for air, flue and exhaust gases (US/CA)

Adjustable DUNGS Pressure Switches AA-A2 for monitoring overpressure, underpressure or differential pressure. Suitable for air, flue, exhaust gases and non-aggressive gases in burner, ventilation and air-conditioning…

SKU 3G-OTH-02960

Also listed as: AAA2USCA · AA A2 US CA

Brand
Dungs
Item
AA-A2 - Pressure Switches for air, flue and exhaust gases
Category
Pressure switch
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Datasheet Content

[{"filename":"aa-a2_datasheet_us_226358.pdf","text":"Differential Pressure Switch\n for air, flue and exhaust gases\n\n AA-A2…\n\n\n\n\n Approvals AA-A2-4 / AA-A2-6\n\n UL Listed\n • UL 353\n • File # MH 16628\n\n CSA Certified\n • CSA C22.2 No. 14\n • File # 201527\n\n FM Approved\n • Class 3510, 3530\n • File # J.I. 0D6A1.AF\n\n Commonwealth of Massachusetts\n Approved Product\n • Approval code G3-0106-191\n • Air pressure switch for differential,\n vacuum or pressure\n\n Codes and Standards\n This product is recommended for\n installations covered by but not lim-\n ited to NFPA 37, NFPA 85, NFPA 86,\n ANSI Z83.4/CSA 3.7, ANSI Z83.18/ Description Application\n CSA 4.9, ANSI Z21.13, CSD-1, AA-A2… differential pressure switches Differential pressure monitoring in firing,\n UL 795, CSA B149.1, CSA B149.3 are field adjustable, compact pressure ventilation and air-conditioning systems.\n and CSA B149.6. switches for automatic burner controls. The AA-A2… can be used as a pressure,\n Available with hose or NPT threaded vacuum or differential pressure switch\n DUNGS is an ISO 9001 connections. for air and non-aggressive gases. Not\n manufacturing facility. suitable for natural gas, propane, butane\n AA-A2-4… differential pressure switch- and other combustable gases.\n es are suitable for making and/or\n breaking a circuit when the medium\n\n\n\n\n AA-A2 Sales Brochure • P/N 226358 • Ed. 10/23\n pressure changes relative to the set\n point. AA-A2-4… versions feature hose\n connections.\n\n AA-A2-6… differential pressure switch-\n es are suitable for making and/or\n breaking a circuit when the medium\n pressure changes relative to the set\n point. AA-A2-6… versions feature NPT\n threaded connections that also include\n1…4 a test button in the lower housing.\n\fAA-A2… SPDT differential pressure switch in pressure and vacuum ranges.The differential pressure acts via the diaphragm\nagainst the force of the setting spring on the microswitch. The pressure switch operates without any auxiliary power\n\nSpecifications\nMax. operating pressure 7 PSI (500 mbar)\nPressure connection AA-A2-4 AA-A2-6\n Hose connection Threaded connection\n 5/32\" (4.6 mm) dia. positive\t\t 1/4\" NPT positive\n 5/32\" (4.6 mm) dia. negative\t\t 1/8\" NPT negative\n \t\t\t\t\t\t 5/32\" (Ø 4.6 mm) test connection\nTemperature range Ambient temperature\t\t\t -40 °F to +140 °F (-40 °C to +60 °C)\n Medium temperature\t\t\t -40 °F to +140 °F (-40 °C to +60 °C)\nMaterials Housing:\t\t\t\t Polycarbonate\n Switch: \t\t\t\t\t Polycarbonate\n Diaphragm: \t\t\t\t NBR-based rubber\n Switching contact:\t\t\t Silver (Ag)\nElectrical ratings AC eff. \t\t\t\t\t min. 24 V max. 250 V\n DC\t\t\t\t\t min. 24 V max. 48 V\nCurrent ratings AC 5A resistive @ 120 VAC\t\t\t\n AC 3A inductive @ 120 VAC \t\t\t\n DC min. 20 mA @ 24 VDC\t\t\n DC max. 1A @ 24 VDC\t\t\t\nElectrical connection Screw terminals via 1/2\" NPT conduit connection\nEnclosure rating NEMA Type 4\nSetting tolerance ±15% switching point deviation referred to set point, adjusted as pressure rises,\n vertical diaphragm position\nInstallation position Multipoised\n\n\n\n\n Installation position: Standard installation position is vertical upright diaphragm. When installed horizontally, the\n pressure switch switches at a pressure higher by approx. 0.2 in. W.C. When installed upside down, the pressure\nswitch switches at a pressure lower by approx. 0.2 in. W.C. When installed in other positions, the pressure switch switches\nat pressure deviating from the set reference value by max. ± 0.2 in. W.C.\n\n\nDefinition of switching hysteresis ∆p AA-A2… switching function\nThe pressure difference between the upper and lower switching pressures. As pressure rises:\n 1 NC opens, 2 NO closes\n As pressure falls:\n 2 NO opens, 1 NC closes\nPressure\nat meter Setpoint tolerance\n Upper switching\n\n\n\n\n Switching hysteresis Δp\n pressure\n\n\n Falling\n\n\n Adjustment as\n Rising Lower switching\n pressure rises pressure\n Medium Pressure\n\n 2…4\n\f Dimensions inch (mm) AA-A2-4… Hose connection\n 1 Pressure connection (+)\n 2 Pressure connection (–)\n\n\n\n\n Dimensions inch (mm) AA-A2-6… Threaded connection\n 1 Pressure connection (+)\n 2 Pressure connection (–)\n 3 Test nipple p(+)\n\n\n\n\n Pressure connection can only be used as test nipple.\n\n\n\n\n (3) Test Nipple\n Test Button\n\n\n\n\n O 3,1\n LK .8)\n (78\n\n\n\n\n 3.7 (94)\n\n\n\n\n 1/2” NPT\n\n\n\n Test button interrupted and the pressure below the If the test button is released, the pres-\n The AA-A2-6… threaded version is diaphragm is relieved.The microswitch of sure below the diaphragm is built up\n equipped with a test button. When the the pressure switch changes the contact again and the microswitch changes to\n test button is pressed, the connection position from NO to NC. its original position.\n3 … 4 to the 1/4\" NPT pressure connection is\n\f Differential Pressure Switch\n for air, flue and exhaust gases\n\n AA-A2…\n\n\n\n\nType Version Connection Order No. Setting range Switching Factory\n Type in. W.C. hysteresis Calibration\n P ↑min. P ↑max.\nAA-A2-4-… AA-A2-4-2 Hose 266910 0.16 - 1.20 ≤ 0.12 ≤ 0.12\npressure switch AA-A2-4-3 Hose 266911 0.40 - 4.00 ≤ 0.20 ≤ 0.20\n…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dungs Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Adjustable DUNGS Pressure Switches AA-A2 for monitoring overpressure, underpressure or differential pressure. Suitable for air, flue, exhaust gases and non-aggressive gases in burner, ventilation and air-conditioning systems. Not suitable for natural gas, propane, butane or other fuel gases.

Frequently Asked Questions

What is the DUNGS AA-A2 pressure switch used for?

The DUNGS AA-A2 is a differential pressure switch used for monitoring overpressure, underpressure, or differential pressure in air, flue, and exhaust gases. It is suitable for burner, ventilation, and air-conditioning systems. It is not suitable for natural gas, propane, butane, or other fuel gases.

What are the specifications of the DUNGS AA-A2 pressure switch?

The DUNGS AA-A2 has a maximum operating pressure of 7 PSI (500 mbar). It features an SPDT switch, ambient and medium temperature range of -40 °F to +140 °F (-40 °C to +60 °C), and electrical ratings of 24 V to 250 V AC or 24 V to 48 V DC. The AA-A2-6 version has 1/4" NPT positive and 1/8" NPT negative threaded connections.

Where to buy DUNGS AA-A2 pressure switches in Singapore?

You can source DUNGS AA-A2 pressure switches in Singapore through 3G Electric. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this UL Listed and CSA Certified model. We provide reliable sourcing for industrial burner and HVAC components.

How to install the DUNGS AA-A2 pressure switch?

Install the DUNGS AA-A2 pressure switch with the pressure connections oriented as per the application. For the AA-A2-6 version, use 1/4" NPT for positive and 1/8" NPT for negative ports. Ensure the ambient temperature stays within -40 °F to +140 °F. The switch operates without auxiliary power and is field adjustable.

Used in

Common applications for Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners

Dungs Products

3G Electric supplies Dungs pressure switch. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

More from Dungs

View all Dungs parts
DUNGS AA-A4 - Pressure Switches for air, flue, exhaust gases (US/CA)
Dungs
DUNGS AA-A4 - Pressure Switches for air, flue, exhaust gases (US/CA)
DUNGS GW...A5 - Compact Pressure Switches for gas, air, flue, exhaust gases and hydrogen for multifunctional device
Dungs
DUNGS GW...A5 - Compact Pressure Switches for gas, air, flue, exhaust gases and hydrogen for multifunctional device
DUNGS GW...A4 HP - Pressure Switches for gas, air, flue, exhaust gases and hydrogen for high pressure application (US/CA)
Dungs
DUNGS GW...A4 HP - Pressure Switches for gas, air, flue, exhaust gases and hydrogen for high pressure application (US/CA)
DUNGS ÜB, NB...A2 - Pressure Limiters for gas, air, flue, exhaust gases and hydrogen for multifunctional gas controls
Dungs
DUNGS ÜB, NB...A2 - Pressure Limiters for gas, air, flue, exhaust gases and hydrogen for multifunctional gas controls
DUNGS G...A2 - Pressure Switches and Pressure Limiters for gas, air, flue and exhaust gases for DUNGS multifunctional device (US/CA)
Dungs
DUNGS G...A2 - Pressure Switches and Pressure Limiters for gas, air, flue and exhaust gases for DUNGS multifunctional device (US/CA)
DUNGS GW...A6 - Compact Pressure Switches for gas, air, flue, exhaust gases and hydrogen
Dungs
DUNGS GW...A6 - Compact Pressure Switches for gas, air, flue, exhaust gases and hydrogen
DUNGS GW 500 A4 - Pressure Switches for gas, air, flue, exhaust gases and hydrogen
Dungs
DUNGS GW 500 A4 - Pressure Switches for gas, air, flue, exhaust gases and hydrogen
DUNGS AA-A1 - Pressure Switches for air, factory adjusted (US/CA)
Dungs
DUNGS AA-A1 - Pressure Switches for air, factory adjusted (US/CA)