Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

DUNGS MB-D(LE) 407-412 B07, One-stage mode, Integrated bypass valve - Gas multibloc
DungsGas multibloc

DUNGS MB-D(LE) 407-412 B07, One-stage mode, Integrated bypass valve

The DUNGS GasMultiBloc® MB-D(LE) 407-412 integrates filter, regulator, valves and pressure switches in one compact fitting.

SKU 3G-OTH-02922

Also listed as: MBDLE407412B07 · MB DLE 407 412 B07

Brand
Dungs
Item
MB-D
Category
Gas multibloc
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Datasheet Content

[{"filename":"mb-dle-407-412-b07_datasheet_en_215195.pdf","text":"GasMultiBloc®\n Combined regulator and\n safety shut-off valves\n Single-stage function\n Integrated bypass valve\n\n MB-D(LE) 407 - 412 B07\n\n 7.22\n\n\n\n\n Technical description The modular system permits individual\n The DUNGS GasMultiBloc® integrates filter, solutions by using an internal bypass valve\n regulator, valves and pressure switches in in connection with separately controlled\n one compact fitting. valves, by adding a valve proving system,\n mini/maxi pressure switches, pressure limit-\n - Dirt trap unit: Fine-mesh sieve ers, limit switches at valve V2.\n - One regulator, two main valves and one\n bypass valve: B07 Application\n - Two valves are fast opening, one valve The modular system permits individual\n is slow opening solutions in gas safety and regulator engi-\n - Solenoid valves up to 360 mbar (36 kPa) neering. Suitable for gases of families 1, 2,\n as per DIN EN 161 Class A Group 2 3 and other neutral gaseous media.\n - Sensitive setting of output pressure by\n proportional regulator as per DIN EN 88 Approvals\n Class A Group 2 EU type testing certificate as per:\n - High flow rates with low pressure drop • EU-Gas Appliances Regulation\n - DC solenoid drive interference degree N • EU-Pressure Equipment Directive\n - Main volume restrictor at valve V2, by- Approvals in other important gas consum-\n pass restrictor at valve V3 ing countries.\n\n\n\n Edition 03.19 • Nr. 215 195\n - Hydraulic opening delay\n - Flange connections with pipe threads as\n per ISO 7/1\n - Simple mounting, compact, light-\n weight\n\n1…6\n\fSpecifications\n\nNominal diameters MB-…407 B07 MB-…410/412 B07\nFlange with pipe threads as per Rp 1/2, 3/4 Rp 3/4, 1, 1 1/4\nISO 7/1 (DIN 2999) and their combinations and their combinations\n\nMax. operating pressure 360 mbar (36 kPa)\n\nOutput pressure ranges MB-… S22 pa: 4 mbar (0.4 kPa) to 20 mbar (2 kPa)\n MB-… S52 pa: 4 mbar (0.4 kPa) to 50 mbar (5 kPa)\n\nMedia Gases of families 1, 2, 3 and other neutral gaseous media\n\nAmbient temperature -15 °C to +70 °C (Do not operate MB-D below 0 °C in liquid gas systems. Only suit-\n able for gaseous liquid gas, liquid hydrocarbons destroy sealing materials.)\n\nDirt trap Fine-mesh sieve. Replacement only possible by dismounting the fitting.\n\nPressure switches Types GW A5, GW A2, NB A2, ÜB A2 mountable as per DIN EN 1854.\n For further information, refer to Datasheet GW A2 No. 215 183 and Datasheet\n GW A5 No. 225 901.\n\nPressure regulator Pressure regulator compensated for residual pressure, leakproof seal when\n switched off by means of valve V1 as per DIN EN 88 Class A. Setpoint spring\n permanently installed (no spring exchange possible). A vent line above roof is\n not required. Internal pulse tap provided.\n\nSolenoid valve V1 Valve as per DIN EN 161 Class A Group 2, fast closing, fast opening\n\nSolenoid valve V2 Valve as per DIN EN 161 Class A Group 2\n Valve V2 design\t\t Main volume restrictor\n MB fast closing fast opening without\n MB-D fast closing fast opening with\n MB-DLE fast closing slow opening with\n MB-LE fast closing slow opening without\n\nSolenoid valve V3 (bypass) Valve as per DIN EN 161 Class A Group 2, with volume restrictor\n\nMeasuring/ignition gas connection For G 1/8 as per DIN ISO 228, refer to Pressure taps on page 4\n\nBurner pressure monitor pBr Connection downstream of valve V2, pressure switch mountable on adapter laterally\n\nVoltage / frequency 50-60 Hz ,220 - 230 V AC, -15% +10%\n\n\nElectrical connection Plug connection as per DIN EN 175301-803\n for valves and pressure switches\n\nRating/power consumption Refer on page 4\nSwitch-on duration 100%\nDegree of protection IP 54 as per IEC 529 (EN 60529)\nRadio interference Interference degree N\n\nMaterials of gas conveying parts Housing\t\t\t aluminium die casting\n Diaphragms, seals\t\t NBR basis, Silopren (silicone rubber)\n Solenoid drive\t\t\t steel, brass, aluminium\n\nInstallation position Solenoid vertically upright or lying horizontally as well as its intermediate posi-\n tions.\n\nClosed position signal contact Closed position signal contact, type K01/1 (DIN-tested), mountable on V2\n\n\n\n\n 2…6\n\f Equipment variants\n GasMultiBloc®...B07 407 B07 410 B07 412 B07\n Single-stage function\n MB • • •\n MB-D • • •\n MB-DLE • • •\n MB-LE • • •\n Microfilter (standard) with sieve • • •\n Gas pressure switch\n downstream of filter • • •\n downstream of valve V2 on adapter • • •\n Pressure regulator • • •\n Valve V1, double seat • • •\n Valve V2, single seat – • –\n Valve V2, double seat • – •\n Valve V3, single seat with restrictor • • •\n Valve opening separately • • • S...2 version\n Flange \t\t Rp 1/2 • – –\n \t\t\t Rp 3/4 • • • • = possible\n \t\t\t Rp 1 – • • (•) = on request\n \t\t\t Rp 1 1/4 – • • - = not possible\n\n\n MB-...B07 version\n\n V1 = Valve 1 4 V3\n V2 = Valve 2\n V3 = Valve 3\n 3 = Filter 3\n 4 = Pressure switch, optional 1\n 5 = Regulator V1 5 V2\n\n\n Mounting of VPS 504 valve proving system possible\n Mounting of K01/1 closed position signal contact possible\n\n\n Type key of MultiBloc®\n\n\n\n\n 0 = common\n 2 = separated\n\n\n 2 = 4 - 20 mbar up to 360 mbar\n 5 = 4 - 50 mbar up to 360 mbar\n\n\n\n\n 1 = two A valves for main gas + regulator\n 7 = two A valves for main gas, one A valve together\n with V1 as internal bypass around V2 + regulator\n\n\n\n\n 403 = DN 10, V2 = Single-seat valve\n 405 = DN 15, V2 = Single-seat valve\n 407 = DN 20, V2 = Double-seat valve\n 410 = DN 25, V2 = Single-seat valve\n 412 = DN 32, V2 = Double-seat valve\n 415 = DN 40, V2 = Double-seat valve\n 420 = DN 50, V2 = Double-seat valve\n\n\n without = (MB or MB-ZR)\n -D = Main volume restrictor\n -LE = adjustable opening behaviour\n -DLE = D + LE combination\n\n without = single stage\n ZR = double-stage with partial volume setting\n first stage\n\n\n\n3…6\n\fDimensions [mm]\n\n\n\n\n f\n e\n h\n\n\n\n\n d\n\n c = Space requirement for cover of pressure switch a\n f = Space requirement for exchanging the solenoid g\n c b\n\n\nType…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dungs Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DUNGS GasMultiBloc® MB-D(LE) 407-412 integrates filter, regulator, valves and pressure switches in one compact fitting.

Frequently Asked Questions

What is the DUNGS MB-D(LE) 407-412 B07 gas multibloc used for?

The DUNGS GasMultiBloc® MB-D(LE) 407-412 B07 is used in industrial gas safety and regulation systems. It integrates a filter, regulator, two main valves, and a bypass valve into one compact fitting, suitable for gases of families 1, 2, 3 and other neutral gaseous media.

What are the specifications of the DUNGS MB-D(LE) 407-412 B07?

The DUNGS MB-D(LE) 407-412 B07 has a maximum operating pressure of 360 mbar (36 kPa) and output pressure ranges of 4 mbar (0.4 kPa) to 20 mbar (2 kPa) for S22 or 4 mbar (0.4 kPa) to 50 mbar (5 kPa) for S52. It features flange connections with pipe threads per ISO 7/1 and operates at ambient temperatures from -15 °C to +70 °C.

Where to buy the DUNGS MB-D(LE) 407-412 B07 in Singapore?

3G Electric supplies the DUNGS MB-D(LE) 407-412 B07 gas multibloc to Singapore. We handle sourcing, logistics, customs clearance, and delivery to your facility. Contact our team for pricing and lead time on this DUNGS component.

How to install the DUNGS MB-D(LE) 407-412 B07 gas multibloc?

Install the DUNGS MB-D(LE) 407-412 B07 by mounting it with flange connections per ISO 7/1 pipe threads. Ensure the ambient temperature stays within -15 °C to +70 °C and avoid operation below 0 °C in liquid gas systems. Use a fine-mesh sieve dirt trap; replacement requires dismounting the fitting.

Used in

Common applications for Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners

Dungs Products

3G Electric supplies Dungs gas multibloc. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
DUNGS MB-D(LE) 403 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 403 B01, One-stage mode
DUNGS MB-ZRD(LE) 405-412 B01, Two-stage function
Dungs
DUNGS MB-ZRD(LE) 405-412 B01, Two-stage function
DUNGS MBC-300/700/1200-SE/N, safety shut-off valves
Dungs
DUNGS MBC-300/700/1200-SE/N, safety shut-off valves
DUNGS MBC-65/120..., One-stage mode
Dungs
DUNGS MBC-65/120..., One-stage mode
DUNGS MB-VEF 415-425 B01, Gas-air-ratio control
Dungs
DUNGS MB-VEF 415-425 B01, Gas-air-ratio control
Valve MBLE 410 B01 S22
Dungs
Valve MBLE 410 B01 S22

More from Dungs

View all Dungs parts
DUNGS MB-VEF 407-412 B01, Gas-air-ratio control
Dungs
DUNGS MB-VEF 407-412 B01, Gas-air-ratio control
DUNGS MB-ZRD(LE) 407-412 B07, Integrated bypass valve
Dungs
DUNGS MB-ZRD(LE) 407-412 B07, Integrated bypass valve
DUNGS MB-ZRD(LE) 415-420 B01, Two-stage function
Dungs
DUNGS MB-ZRD(LE) 415-420 B01, Two-stage function
DUNGS MBC-...-VEF, Infinitely variable air/gas ratio control mode
Dungs
DUNGS MBC-...-VEF, Infinitely variable air/gas ratio control mode
DUNGS MBC-...-SE, Combined servo pressure regulator and safety shut-off valves
Dungs
DUNGS MBC-...-SE, Combined servo pressure regulator and safety shut-off valves
DUNGS MB-D(LE) 405-412 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 405-412 B01, One-stage mode
DUNGS MB-D(LE) 415-420 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 415-420 B01, One-stage mode
DUNGS MBC-WND - DUNGS WhirlWind System®
Dungs
DUNGS MBC-WND - DUNGS WhirlWind System®