Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

DUNGS MBC-WND - DUNGS WhirlWind System® - Gas multibloc
DungsGas multibloc

DUNGS MBC-WND - DUNGS WhirlWind System®

The DUNGS WhirlWind System® 3G-OTH-02937 as integrated Gas-Air System with high power density based on DUNGS zero pressure multiple actuator MBC to EN 161 for modulating or multi-stage mode.

SKU 3G-OTH-02937

Also listed as: MBCWND · MBC WND

Brand
Dungs
Item
MBC-WND - DUNGS WhirlWind System®
Category
Gas multibloc
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Datasheet Content

[{"filename":"mbc-wnd_datasheet_en_252945.pdf","text":"Program overview\n DUNGSWhirlWindSystem®\n 9 - 1 000 kW\n\n 7.60\n\n\n\n\n Just the right mix!\n\n\n\n\n Technical Description\n Integrated gas-air system with high - Limits maximum flow by a low hyster-\n power density based on DUNGS zero esis flow restrictor, injector requires\n pressure multiple actuator MBC to no replacement for different gas\n EN 161 for modulating or multi-stage families\n mode: - Implemented by adapting system\n components and optimising to spe-\n - Pneumatic integrated system com- cific application and design require-\n prising zero pressure mode and ments.\n integrated signal gain possible\n\n\n\n\n Printed in Germany • Edition 01.20 • Nr. 252 945\n - Inlet pressure Application\n 3G-OTH-02937 65: For pre-mix burners and forced-draft\n pmax 65 mbar (6.5 kPa) burners.\n 3G-OTH-02937 120 - 1 200: Suitable for gases to EN 437 and other\n pmax 100 mbar (10 kPa) gaseous inert media.\n - Modulation range up to 1:10\n - Breaks up flow pattern and reduces\n resonances\n - Offset correction of gas/air ratio at\n servo regulator\n1…4\n\fWhirlWind Family from 9 kW up to 1 000 kW\nProduct kW Swirlplate Accessories Valve class EU US\n design design\n CE CSA\n 30 white ✔ —\nMBC-65-WND 60 red Without ✔ —\n 90 grey ✔ —\n 90 Air and gas ✔ —\n pressure\nMBC-120-WND 120 ✔ —\n switch\n 150 LGW, GW ✔ —\n 2xA\n 175 ✔ ✔\nMBC-300-WND\n 340 Air and gas\n black ✔ ✔\n pressure\n 550 switch ✔ ✔\n\nMBC-700-WND 700 LGW, GW ✔ ✔\n\n 1 000 Valve proving ✔ ✔\n system VPS\nMBC-1200-WND 1 000 ✔ ✔\n\n\n\n\nPower ranges\n\nTyp\n\n\n\n\n 200 - 1 000 kW\n\n\n\n 50 - 1 000 kW\n\n\n\n 30 - 340 kW\n\n\n\n\n MBC-90\n 9 - 90 kW\n\n\n\n\n kW\n\n\n\n\n 2…4\n\f Swirlplate - The heart of the WhirlWind system\n\n Integrated Venturi\n 2. Signal amplifier\n\n Swirplate\n + Patented\n + Two stage cascaded\n signal amplification\n + Breaks up uniform flow\n pattern and reduces\n resonances\n\n\n\n\n Silencer pocket\n\n\n Spiral swirl plate\n 1. Signal amplifier\n\n\n\n Specifica- MBC-65-WND MBC-120-WND MBC-300-WND MBC-700-WND MBC-1200-WND\n tions\n pmax. 65 mbar (6.5 kPa) 100 mbar (10 kPa)\n Nominal Rp ½ Rp ¾ Rp ½, ¾, 1, 1 ¼ Rp 1, 1 ¼, 1 ½, 2 Rp 2\n diameter Rp\n Nominal — — NPT ½, ¾, 1, 1 ¼ NPT 1, 1 ¼, 1 ½, 2 NPT 2\n diameter NPT\n Electrical\n Plug-in connection as per DIN EN 175301-803\n connection\n Installation\n Vertical with upright solenoid\n position\n Ambient -15 °C to +70 °C\n temperature 0 °C to +70 °C (LPG)\n Voltage ~(AC) 50 - 60 Hz 230 V +10 % / –15 %\n Further voltages on request\n Approvals CE CE, CSA\n\n For further information, refer to Datasheets\n 7.01 MBC-...-SE/N\n 7.10 MBC-65/120-...\n\n\n\n\n3…4\n\f Program overview\n DUNGSWhirlWindSystem®\n 9 - 1 000 kW\n\n\n\n\nWe reserve the right to make any changes in the interest of technical progress.\n Head Offices and Factory Postal adress\n Karl Dungs GmbH & Co. KG Karl Dungs GmbH & Co. KG\n Karl-Dungs-Platz 1 Postfach 12 29\n D-73660 Urbach, Germany D-73602 Schorndorf, Germany\n Telefon +49 7181-804-0 e-mail info@dungs.com\n Telefax +49 7181-804-166 Internet www.dungs.com 4…4"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dungs Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DUNGS WhirlWind System® 3G-OTH-02937 as integrated Gas-Air System with high power density based on DUNGS zero pressure multiple actuator MBC to EN 161 for modulating or multi-stage mode.

Frequently Asked Questions

What is the DUNGS WhirlWind System 3G-OTH-02937 used for?

The DUNGS WhirlWind System 3G-OTH-02937 is an integrated gas-air system designed for pre-mix burners and forced-draft burners. It provides high power density for modulating or multi-stage mode, suitable for gases to EN 437 and other gaseous inert media, with a power range from 9 kW to 1 000 kW.

What are the specifications of the DUNGS 3G-OTH-02937 gas multibloc?

The DUNGS 3G-OTH-02937 features inlet pressure up to 65 mbar (6.5 kPa) for 3G-OTH-02937 65 and up to 100 mbar (10 kPa) for 3G-OTH-02937 120-1200. Nominal diameters range from Rp ½ to Rp 2, with electrical connection via plug-in per DIN EN 175301-803. Ambient temperature is -15 °C to +70 °C (0 °C to +70 °C for LPG).

Where to buy the DUNGS WhirlWind System in Singapore?

3G Electric supplies the DUNGS WhirlWind System 3G-OTH-02937 to Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact our team for pricing and lead time on this gas multibloc for pre-mix and forced-draft burner applications.

How to install the DUNGS 3G-OTH-02937 gas-air system?

Install the DUNGS 3G-OTH-02937 vertically with the solenoid upright. Ensure ambient temperature stays within -15 °C to +70 °C (0 °C to +70 °C for LPG). Use the plug-in electrical connection per DIN EN 175301-803. For detailed setup, refer to the manufacturer's datasheets for MBC-...-SE/N and MBC-65/120-... series.

Used in

Common applications for Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners

Dungs Products

3G Electric supplies Dungs gas multibloc. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Related products

More from Dungs

View all Dungs parts
DUNGS MB-VEF 407-412 B01, Gas-air-ratio control
Dungs
DUNGS MB-VEF 407-412 B01, Gas-air-ratio control
DUNGS MB-ZRD(LE) 407-412 B07, Integrated bypass valve
Dungs
DUNGS MB-ZRD(LE) 407-412 B07, Integrated bypass valve
DUNGS MB-ZRD(LE) 415-420 B01, Two-stage function
Dungs
DUNGS MB-ZRD(LE) 415-420 B01, Two-stage function
DUNGS MBC-...-VEF, Infinitely variable air/gas ratio control mode
Dungs
DUNGS MBC-...-VEF, Infinitely variable air/gas ratio control mode
DUNGS MBC-...-SE, Combined servo pressure regulator and safety shut-off valves
Dungs
DUNGS MBC-...-SE, Combined servo pressure regulator and safety shut-off valves
DUNGS MB-D(LE) 405-412 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 405-412 B01, One-stage mode
DUNGS MB-D(LE) 415-420 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 415-420 B01, One-stage mode
DUNGS MBC-300/700/1200-SE/N, safety shut-off valves
Dungs
DUNGS MBC-300/700/1200-SE/N, safety shut-off valves