Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
DwyerAdjustable Set-Point Air Pressure Switches

Dwyer Pressure Switch: Adj, 0.15 in wc to 1.5 in wc, SPDT, 1/8 in Sample Line Connection Size

The DWYER 1627-1 is an adjustable set-point air pressure switch with a SPDT contact configuration. It features a set-point range of 0.15 in wc to 1.5 in wc and a 1/8 in NPT sample line connection. The switch operates…

SKU 3G-OTH-69513

Also listed as: 16271 · 1627 1

Brand
Dwyer
Item
Pressure Switch: Adj, 0.15 in wc to 1.5 in wc, SPDT, 1/8 in Sample Line Connection Size
Category
Adjustable Set-Point Air Pressure Switches
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Dwyer
Manufacturer Part Number
1627-1
Type
0.15 in wc to 1.5 in wc, SPDT, NPT
Switch Voltage
120 to 480V AC
Sample Line Connection Size
1/8 in

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dwyer Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DWYER 1627-1 is an adjustable set-point air pressure switch with a SPDT contact configuration. It features a set-point range of 0.15 in wc to 1.5 in wc and a 1/8 in NPT sample line connection. The switch operates at 120 to 480V AC.

Frequently Asked Questions

What is the Dwyer 1627-1 pressure switch used for?

The Dwyer 1627-1 adjustable set-point air pressure switch is used to monitor or control air pressure in HVAC, ventilation, and industrial air-handling systems. It actuates an SPDT contact when pressure reaches the set point, enabling alarms, fan control, or filter monitoring.

What are the specifications of the Dwyer 1627-1 pressure switch?

The Dwyer 1627-1 has a set-point range of 0.15 in wc to 1.5 in wc, an SPDT contact configuration, and a 1/8 in NPT sample line connection. It operates at 120 to 480V AC. The manufacturer part number is 1627-1.

Where to buy the Dwyer 1627-1 pressure switch worldwide?

3G Electric supplies the Dwyer 1627-1 pressure switch worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

How to install the Dwyer 1627-1 pressure switch?

Mount the Dwyer 1627-1 in a clean, dry location. Connect the 1/8 in NPT sample line to the pressure source. Wire the SPDT contacts according to your control circuit (120 to 480V AC). Adjust the set-point screw to the desired trip pressure. Verify operation with a manometer.

Used in

Common applications for Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Products

3G Electric supplies Dwyer adjustable set-point air pressure switches. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Pressure Switch: Adj, 0.5 in wc to 6 in wc, SPDT, 1/8 in Sample Line Connection Size, NPT (MPN 1626-5)
Dwyer
Pressure Switch: Adj, 0.5 in wc to 6 in wc, SPDT, 1/8 in Sample Line Connection Size, NPT (MPN 1626-5)
Dwyer
Dwyer
Pressure Switch: Adj, 3 in wc to 12 in wc, Conduit Box, SPDT, 1/8 in Sample Line Connection Size (MPN 1638-10)
Air Pressure Switch: Adj, 0.07 in wc to 0.15 in wc, SPDT, 1/8 in Sample Line Connection Size, NPT (MPN 1910-00)
Dwyer
Air Pressure Switch: Adj, 0.07 in wc to 0.15 in wc, SPDT, 1/8 in Sample Line Connection Size, NPT (MPN 1910-00)
Dwyer
Dwyer
Pressure Switch: Adj, 0.05 in wc to 0.25 in wc, Conduit Box, SPDT, NPT, 1/8 in NPT (MPN 1638-0)
Pressure Switch: Adj, 1 in wc to 3 in wc, Conduit Box, SPDT, 1/8 in Sample Line Connection Size, NPT (MPN 1638-2)
Dwyer
Pressure Switch: Adj, 1 in wc to 3 in wc, Conduit Box, SPDT, 1/8 in Sample Line Connection Size, NPT (MPN 1638-2)
Large Diaphragm Pressure Switch: Adj, 0.2 in wc to 1 in wc, SPDT, 1/8 in Sample Line Connection Size (MPN 1638-1)
Dwyer
Large Diaphragm Pressure Switch: Adj, 0.2 in wc to 1 in wc, SPDT, 1/8 in Sample Line Connection Size (MPN 1638-1)

More from Dwyer

View all Dwyer parts
Dwyer
Dwyer
Pressure Switch: Adj, Auto Reset, 5 in wc to 44 in wc, Conduit Box, SPDT, NPT, 120 to 480V AC (MPN 1823-40)
Manual Reset Pressure Switch: Adj, Manual Reset, 3 in wc to 11.75 in wc, SPDT, NPT, 1/8 in NPT (MPN 1900-10-MR)
Dwyer
Manual Reset Pressure Switch: Adj, Manual Reset, 3 in wc to 11.75 in wc, SPDT, NPT, 1/8 in NPT (MPN 1900-10-MR)
Differential Pressure Switch: Adj, 0.15 in wc to 0.5 in wc, SPDT, 1/8 in Sample Line Connection Size (MPN 1910-0)
Dwyer
Differential Pressure Switch: Adj, 0.15 in wc to 0.5 in wc, SPDT, 1/8 in Sample Line Connection Size (MPN 1910-0)
Pressure Switch: Adj, 5 psig to 150 psig, Conduit Box, SPST, NPT, 120V AC/240V AC/DC (MPN DA-31-2-7)
Dwyer
Pressure Switch: Adj, 5 psig to 150 psig, Conduit Box, SPST, NPT, 120V AC/240V AC/DC (MPN DA-31-2-7)
Pressure Switch: Adj, Auto Reset, 0.3 in wc to 1 in wc, Conduit Box, SPDT, NPT, 120 to 480V AC (MPN 1823-1)
Dwyer
Pressure Switch: Adj, Auto Reset, 0.3 in wc to 1 in wc, Conduit Box, SPDT, NPT, 120 to 480V AC (MPN 1823-1)
Air Pressure Switch: Adj, Auto Reset, 0.8 in wc to 4 in wc, Std Housing, SPDT, Push-On, 250V AC (MPN ADPS-05-2-N)
Dwyer
Air Pressure Switch: Adj, Auto Reset, 0.8 in wc to 4 in wc, Std Housing, SPDT, Push-On, 250V AC (MPN ADPS-05-2-N)
Pressure Switch: Adj, 0.4 in wc to 1.6 in wc, SPDT, 1/8 in Sample Line Connection Size, NPT (MPN 1910-1)
Dwyer
Pressure Switch: Adj, 0.4 in wc to 1.6 in wc, SPDT, 1/8 in Sample Line Connection Size, NPT (MPN 1910-1)
Air Pressure Switch: Adj, Auto Reset, 0.2 in wc to 2 in wc, Std Housing, SPDT, Push-On, 250V AC (MPN ADPS-03-2-N)
Dwyer
Air Pressure Switch: Adj, Auto Reset, 0.2 in wc to 2 in wc, Std Housing, SPDT, Push-On, 250V AC (MPN ADPS-03-2-N)