Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Dwyer Air Pressure Switch: Adj, 0.07 in wc to 0.15 in wc, SPDT - Adjustable Set-Point Air Pressure Switches
DwyerAdjustable Set-Point Air Pressure Switches

Dwyer Air Pressure Switch: Adj, 0.07 in wc to 0.15 in wc, SPDT

The Dwyer 1910-00 is an adjustable set-point air pressure switch with a range of 0.07 in wc to 0.15 in wc, SPDT switching, and a 1/8 in NPT sample line connection.

SKU 3G-OTH-68877

Also listed as: 191000 · 1910 00

Brand
Dwyer
Item
Air Pressure Switch: Adj, 0.07 in wc to 0.15 in wc, SPDT
Category
Adjustable Set-Point Air Pressure Switches
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Dwyer
Manufacturer Part Number
1910-00
Type
0.07 in wc to 0.15 in wc, SPDT, NPT
Sample Line Connection Size
1/8 in

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dwyer Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Dwyer 1910-00 is an adjustable set-point air pressure switch with a range of 0.07 in wc to 0.15 in wc, SPDT switching, and a 1/8 in NPT sample line connection.

Frequently Asked Questions

What is the Dwyer 1910-00 air pressure switch used for?

The Dwyer 1910-00 adjustable air pressure switch detects low differential air pressure in HVAC, cleanroom, and industrial ventilation systems. It actuates an SPDT contact when pressure reaches the set point between 0.07 in wc and 0.15 in wc, enabling alarm or control functions.

What are the specifications of the Dwyer 1910-00?

The Dwyer 1910-00 is an adjustable set-point air pressure switch with a range of 0.07 in wc to 0.15 in wc. It features an SPDT output, a 1/8 in NPT sample line connection, and is manufactured by Dwyer. It is suitable for low-pressure sensing in air-handling equipment.

Where to buy the Dwyer 1910-00 worldwide?

3G Electric supplies the Dwyer 1910-00 adjustable air pressure switch to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for a quote and lead time; we source genuine Dwyer components for industrial applications globally.

How to install the Dwyer 1910-00 air pressure switch?

Mount the Dwyer 1910-00 in a clean, dry location with the pressure ports oriented downward to prevent moisture ingress. Connect the 1/8 in NPT sample line to the high-pressure port. Adjust the set-point screw to the desired trip pressure between 0.07 in wc and 0.15 in wc, then verify operation with a manometer.

Used in

Common applications for Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Products

3G Electric supplies Dwyer adjustable set-point air pressure switches. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Pressure Switch: Adj, 0.5 in wc to 6 in wc, SPDT, 1/8 in Sample Line Connection Size, NPT (MPN 1626-5)
Dwyer
Pressure Switch: Adj, 0.5 in wc to 6 in wc, SPDT, 1/8 in Sample Line Connection Size, NPT (MPN 1626-5)
Dwyer
Dwyer
Pressure Switch: Adj, 0.15 in wc to 1.5 in wc, SPDT, 1/8 in Sample Line Connection Size, NPT (MPN 1627-1)
Large Diaphragm Pressure Switch: Adj, 0.2 in wc to 1 in wc, SPDT, 1/8 in Sample Line Connection Size (MPN 1638-1)
Dwyer
Large Diaphragm Pressure Switch: Adj, 0.2 in wc to 1 in wc, SPDT, 1/8 in Sample Line Connection Size (MPN 1638-1)
Dwyer
Dwyer
Pressure Switch: Adj, 0.05 in wc to 0.25 in wc, Conduit Box, SPDT, NPT, 1/8 in NPT (MPN 1638-0)
Dwyer
Dwyer
Pressure Switch: Adj, 3 in wc to 12 in wc, Conduit Box, SPDT, 1/8 in Sample Line Connection Size (MPN 1638-10)
Pressure Switch: Adj, 3 in wc to 11.75 in wc, SPDT, 1/8 in Sample Line Connection Size, NPT (MPN 1910-10)
Dwyer
Pressure Switch: Adj, 3 in wc to 11.75 in wc, SPDT, 1/8 in Sample Line Connection Size, NPT (MPN 1910-10)

More from Dwyer

View all Dwyer parts
Dwyer
Dwyer
Pressure Switch: Adj, Auto Reset, 5 in wc to 44 in wc, Conduit Box, SPDT, NPT, 120 to 480V AC (MPN 1823-40)
Manual Reset Pressure Switch: Adj, Manual Reset, 3 in wc to 11.75 in wc, SPDT, NPT, 1/8 in NPT (MPN 1900-10-MR)
Dwyer
Manual Reset Pressure Switch: Adj, Manual Reset, 3 in wc to 11.75 in wc, SPDT, NPT, 1/8 in NPT (MPN 1900-10-MR)
Differential Pressure Switch: Adj, 0.15 in wc to 0.5 in wc, SPDT, 1/8 in Sample Line Connection Size (MPN 1910-0)
Dwyer
Differential Pressure Switch: Adj, 0.15 in wc to 0.5 in wc, SPDT, 1/8 in Sample Line Connection Size (MPN 1910-0)
Pressure Switch: Adj, 5 psig to 150 psig, Conduit Box, SPST, NPT, 120V AC/240V AC/DC (MPN DA-31-2-7)
Dwyer
Pressure Switch: Adj, 5 psig to 150 psig, Conduit Box, SPST, NPT, 120V AC/240V AC/DC (MPN DA-31-2-7)
Pressure Switch: Adj, Auto Reset, 0.3 in wc to 1 in wc, Conduit Box, SPDT, NPT, 120 to 480V AC (MPN 1823-1)
Dwyer
Pressure Switch: Adj, Auto Reset, 0.3 in wc to 1 in wc, Conduit Box, SPDT, NPT, 120 to 480V AC (MPN 1823-1)
Air Pressure Switch: Adj, Auto Reset, 0.8 in wc to 4 in wc, Std Housing, SPDT, Push-On, 250V AC (MPN ADPS-05-2-N)
Dwyer
Air Pressure Switch: Adj, Auto Reset, 0.8 in wc to 4 in wc, Std Housing, SPDT, Push-On, 250V AC (MPN ADPS-05-2-N)
Pressure Switch: Adj, 0.4 in wc to 1.6 in wc, SPDT, 1/8 in Sample Line Connection Size, NPT (MPN 1910-1)
Dwyer
Pressure Switch: Adj, 0.4 in wc to 1.6 in wc, SPDT, 1/8 in Sample Line Connection Size, NPT (MPN 1910-1)
Air Pressure Switch: Adj, Auto Reset, 0.2 in wc to 2 in wc, Std Housing, SPDT, Push-On, 250V AC (MPN ADPS-03-2-N)
Dwyer
Air Pressure Switch: Adj, Auto Reset, 0.2 in wc to 2 in wc, Std Housing, SPDT, Push-On, 250V AC (MPN ADPS-03-2-N)