Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Fireye Pressure Sensor. The BLPS - Sensors
FireyeSensors

Fireye Pressure Sensor. The BLPS

The 3G-OTH-02820, TS350 and TS752 series of pressure and temperature sensors are designed for use with the Nexus PPC4000 fuel air ratio controller and BurnerLogiX burner management system with integrated boiler control.

SKU 3G-OTH-02820

Brand
Fireye
Item
Pressure Sensor. The BLPS
Category
Sensors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Fireye
Models
BLPS, TS350, TS752, PPC4000
Category
Sensors

Datasheet Content

[{"filename":"BLZPTS-1-Pressure_and_Temperature_Sensors_for_BurnerLogiX_and_Nexus_PPC4000.pdf","text":"®\n\n BLZPTS-1\n NOVEMBER 19, 2013\n\n\n\n PRESSURE AND\n TEMPERATURE\n SENSORS\n TS350 for use with the\n BURNERLOGIX\n Burner Management\n 3G-OTH-02820\n System and\n PPC4000 Series\n Fuel/Air Ratio\n TS752\n Controller\n\n\n\nDESCRIPTION\n The 3G-OTH-02820, TS350 and TS752 Series of pressure and temperature sensors are designed for\n use with the PPC4000 Fuel Air Ratio Controller and BurnerLogix Burner Management\n System with Integrated Boiler Control.\n The pressure sensors (P/N 3G-OTH-02820-x) utilize a solid state pressure transducer to indicate\n steam pressure. The temperature sensors (P/N TS350-x and TS752-x) utilize a platinum,\n positive temperature coefficient sensing element to provide indication of water tempera-\n ture, stack temperature, boiler water temperature of a steam boiler, and outdoor air temper-\n ature. The pressure sensors have a maximum overpressure specification of 200% Full Scale\n Output and 800% Burst. The pressure sensors are equipped with a 1/4\" NPT male fitting.\n The Immersion Style Temperature Sensors have a 1/2\" NPT mounting for the 2\", 4\" and 8\"\n thermowell probe.\n The pressure and temperature sensors provide a 4-20 mA control signal over their respec-\n tive stated ranges to the PPC4000 and BurnerLogix Control systems. No setting or calibra-\n tion is required for either type of sensor.\n The PPC4000 and BurnerLogix Control systems perform continuous safety checks on the\n operation of all pressure and temperature sensors to insure their safe and proper operation\n (e.g. under range, over range, open wiring, etc.).\n\n\n WARNING: The PPC4000 Fuel Air ratio Controller and BurnerLogix Control\n System must only be used with the approved pressure and temperature sensors.\n (e.g.: 3G-OTH-02820-15, TS350-4, etc.). Do not use with any other types of pressure or tem-\n perature sensors. UL approval requires these sensors.\n\n\n\n\n 1\n\f \n\n\n\n\n Fireye P/N Description\n 3G-OTH-02820-15 Pressure transducer, 0 to 15 psi (0 to 1030 mb), 4-20 mA output linear with pressure. ¼\" NPT mount-\n ing. Screw terminal connections and conduit adapter cover.\n 3G-OTH-02820-25 Pressure transducer, -14.7 to 25 psi (-1013 to 1720 mb), 4-20 mA output linear with pressure. ¼\" NPT\n mounting. Screw terminal connections and conduit adapter cover.\n 3G-OTH-02820-30 Pressure transducer, 0 to 30 psi (0 to 2070 mb), 4-20 mA output linear with pressure. ¼\" NPT mount-\n ing. Screw terminal connections and conduit adapter cover.\n 3G-OTH-02820-200 Pressure transducer, 0 to 200 psi (0 to 13.8 Bar), 4-20 mA output linear with pressure. ¼\" NPT mount-\n ing. Screw terminal connections and conduit adapter cover.\n 3G-OTH-02820-300 Pressure transducer, 0 to 300 psi (0 to 20.7 Bar), 4-20 mA output linear with pressure. ¼\" NPT mount-\n ing. Screw terminal connections and conduit adapter cover.\n TS350-2 Temperature sensor, Range 32°F to 350°F (0°C to 176°C), 4-20 mA output, linear with temperature.\n Insertion length is 2 inches. Stainless steel thermowell included with ½\"-14 NPT mounting.\n TS350-4 Temperature sensor, Range 32°F to 350°F (0°C to 176°C), 4-20 mA output, linear with temperature.\n Insertion length is 4 inches. Stainless steel thermowell included with ½\"-14 NPT mounting.\n TS350-8 Temperature sensor, Range 32°F to 350°F (0°C to 176°C), 4-20 mA output, linear with temperature.\n Insertion length is 8 inches. Stainless steel thermowell included with ½\"-14 NPT mounting.\n TS752-2 Temperature sensor, Range 32°F to 752°F (0°C to 176°C), 4-20 mA output, linear with temperature.\n Insertion length is 2 inches. Stainless steel thermowell included with ½\"-14 NPT mounting.\n TS752-4 Temperature sensor, Range 32°F to 752°F (0°C to 176°C), 4-20 mA output, linear with temperature.\n Insertion length is 4 inches. Stainless steel thermowell included with ½\"-14 NPT mounting.\n TS752-8 Temperature sensor, Range 32°F to 752°F (0°C to 176°C), 4-20 mA output, linear with temperature.\n Insertion length is 8 inches. Stainless steel thermowell included with ½\"-14 NPT mounting.\n Note: 3G-OTH-02820-25 is not compatible with the Burnerlogix Control System\nGENERAL SPECIFICATIONS\n Temperature Sensors:\n Temperature Measurement Range:\n TS350-X: 32°F to 350°F (0°C to 176°C)\n TS752-X: 32°F to 752°F (0°C to 400°C)\n RTD Type: Platinum, 100 ohms +-0.1% @32°F (0°C)\n Temperature Coefficient: .00385 ohms/ohms/C\n Output: 4-20 mA, linear with temperature\n Operating Temperature Range: -13°F to 185°F (-25°C to 85°C)\n Accuracy: +/- 0.75% of span\n Thermowell Case: 300 Series stainless steel\n Mechanical Fittings: 1/2-14 NPT\n\n Pressure Sensors:\n Pressure Measurement Range: 0 to 15, -14.7 to 25, 0 to 30, 0 to 200, 0 to 300 psig\n Excitation Voltage: 9-30Vdc (supplied by BurnerLogix control)\n Accuracy: +/- 0.25% Full Scale (at constant temperature)\n Output: 4-20 mA, linear with pressure\n Maximum Over Pressure: 200% of full scale\n Maximum Burst Pressure: 800% of full scale\n Operating Temperature Range: -40°F to 185°F (-40°C to 85°C)\n Fitting: 1/4\" NPT Male\n Electrical: 1/2\" Conduit and Terminal Strip\n\n\n2\n\f ®\n\n\n\n\n APPROVALS\n Underwriters Laboratories Inc.:\n MCCZ File MP1537\n Controls, Primary Safety - Listed\n MCCZ2 File MP1537\n Controls, Primary Safety - Component\n MCCZ7 File MP1537\n Controls, Primary Safety Certified for Canada\n MCCZ8 File MP1537\n Controls, Primary Safety Certified for Canada - Component\n Factory Mutual: FM Class 7610\n Acceptable by: Industrial Risk Insurers (I.R.I.)\n\nFIGURE 1. Pressure Sensor - 3G-OTH-02820-15, -25, -30, -200, -300\n\n\n\n\n GND\n\n\n COM OUT EXC\n\n\n\n\n 3\n\f \n\n\n\nFIGURE 2. Temperature Sensor - TS350-2, TS350-4, TS350-8\n\n\n\n\nFIGURE 3. Temperature Sensor - TS752-2, TS752-4, TS752-8\n\n 11.0” [279]\n\n\n 7.5” [191]\n\n\n\n\n 0.625”\n\n\n\n\n X = 2”, 4” or 8”\n\n\n\n\n WARNING:\n 1. Read these instructions carefully. Failure to follow them could result in a hazardous or\n dangerous condition.\n 2. Insure that the range of the selected sensor is appropriate for the application. Note: A\n general rule to follow when selecting the sensor range is that the expected value of the\n monitored pressure or sensor should fall between 40-70% of the upper range of the sensor.\n For example, a steam boiler maintains 20 lbs. pressure, select the 3G-OTH-02820-30 Pressure Sensor,\n with a 0-30 PSIG range\n 3. The sensors must be located where the ambient temperature will not exceed the maximum\n ambient operating temperature specified for the sensor.\n 4. Insure that the pressure range programmed on the BurnerLogix Boiler Room Control\n matches the installed pressure sensor. Refer to Bulletin BLZ-1001.\n 5. Do not mount any of the sensors where they could be used as a footstep.\n 6. Installation must be performed by a trained, experienced flame safeguard technician.\n\n\n\n\n4\n\f ®\n\n\n\n\n WARNING: The electro-mechanical high steam limit and/or high hot water temperature\n limit MUST REMAIN in the running interlock circuit of the flame safeguard control.\n\n\n MOUNTING PRESSURE SENSORS\n Note: Refer to Figure 4.\n 1. The steam pressure sensors (3G-OTH-02820-15, -25, -30, -200, -300) provide a 1/4” NPT male fitting for\n connection to the steam header. Included is a 1/4” coupling.\n 2. Make sure the boiler is shut down and zero steam pressure exists in the boiler vessel.\n 3. Disconnect power to the boiler controller so the boiler cannot sequence during installation of the\n steam pressure sensor.\n 4. Always mount the steam pressure sensor above the water line of the boiler.\n 5. Locate the pressure sensors where the ambient temperature will not exceed 185F\n\nFIGURE 4.\n\n STEAM PRESSURE\n OR HOT WATER SENSOR\n ELECTRO-MECHANICAL\n HIGH LIMIT\n (STEAM OR WATER)\n\n\n\n\n 6. Although the…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fireye Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The 3G-OTH-02820, TS350 and TS752 series of pressure and temperature sensors are designed for use with the Nexus PPC4000 fuel air ratio controller and BurnerLogiX burner management system with integrated boiler control.

Frequently Asked Questions

What is the Fireye 3G-OTH-02820 pressure sensor used for?

The Fireye 3G-OTH-02820 pressure sensor is used with the Nexus PPC4000 fuel air ratio controller and BurnerLogiX burner management system to indicate steam pressure. It provides a 4-20 mA control signal and requires no calibration.

What are the specifications of the Fireye 3G-OTH-02820 pressure sensor?

The Fireye 3G-OTH-02820 pressure sensor uses a solid state transducer, offers a 4-20 mA output linear with pressure, and has a 1/4" NPT male fitting. Models include 3G-OTH-02820-15 (0-15 psi), 3G-OTH-02820-25 (-14.7 to 25 psi), 3G-OTH-02820-30 (0-30 psi), and 3G-OTH-02820-200 (0-200 psi). Maximum overpressure is 200% Full Scale.

Where to buy Fireye 3G-OTH-02820 pressure sensors in Singapore?

3G Electric supplies Fireye 3G-OTH-02820 pressure sensors to Singapore. We source and deliver these sensors, handling logistics and customs clearance for your order. Contact us for availability and lead time.

How to install the Fireye 3G-OTH-02820 pressure sensor?

Install the Fireye 3G-OTH-02820 pressure sensor using its 1/4" NPT male fitting into a compatible port. Connect screw terminals per the PPC4000 or BurnerLogiX wiring diagram. No calibration is needed. Ensure only approved Fireye sensors are used for UL compliance.

Used in

Common applications for Fireye
Power-plant auxiliary boiler — M-Series II controller with UV flame scanner, programmed for gas/oil switchover and flame-presence monitoring.
Refinery process heater — MP100E programmer module managing multi-stage ignition and flame-out shutdown interlocks on high-pressure burners.
Petrochemical facility thermal oxidizer — MAUV1T UV amplifier module processing scanner signal from high-temperature burner housings with immune-response filtering.
Large-scale industrial oven (metal treating) — M-Series II with remote reset capability and dual-fuel solenoid isolation for operator safety and burner protection.
Cogeneration plant fuel-gas burner — Fireye scanner and modular controller stack integrated into BMS with remote monitoring of flame status and controller fault codes.

Fireye Products

3G Electric supplies Fireye sensors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
The Fireye BLPS-200 is an electronic pressure transducer for HVACR and industrial burner systems. It monitors gas or air pressure and provides feedback to burner management controllers for safe combustion in boilers, furnaces, and process heaters
Fireye
The Fireye BLPS-200 is an electronic pressure transducer for HVACR and industrial burner systems. It monitors gas or air pressure and provides feedback to burner management controllers for safe combustion in boilers, furnaces, and process heaters
PF Series MBPF-100S Burner Control. The MBPF-100S, MB-600PF, MBPF-200S and MBPF-202S modules provide visual indication and electrical output that signal the user regarding flame presence in a combustion chamber. The module uses Fireye optical ultra-violet scanners and/or flame rods to sense flame presence independently or as components in a burner management system
Fireye
PF Series MBPF-100S Burner Control. The MBPF-100S, MB-600PF, MBPF-200S and MBPF-202S modules provide visual indication and electrical output that signal the user regarding flame presence in a combustion chamber. The module uses Fireye optical ultra-violet scanners and/or flame rods to sense flame presence independently or as components in a burner management system
MBCE Flame Sensor Modules. The modules use Fireye flame rods or UV scanners to sense flame presence independently or as components in a burner management system. These modules have many operational characteristics are provided including:
Fireye
MBCE Flame Sensor Modules. The modules use Fireye flame rods or UV scanners to sense flame presence independently or as components in a burner management system. These modules have many operational characteristics are provided including:
Flame sensor for use in HVACR and burner systems. Detects flame presence and signals the control system to maintain fuel supply only when a stable flame is present, preventing unburned fuel accumulation
Fireye
Flame sensor for use in HVACR and burner systems. Detects flame presence and signals the control system to maintain fuel supply only when a stable flame is present, preventing unburned fuel accumulation
Temperature sensor for HVACR systems, used to monitor and control temperature in commercial and industrial heating applications. Suitable as a replacement component in burner management and flame safeguard systems
Fireye
Temperature sensor for HVACR systems, used to monitor and control temperature in commercial and industrial heating applications. Suitable as a replacement component in burner management and flame safeguard systems
Temperature sensor for use in HVAC and combustion systems. Monitors and controls temperature for burner management and flame safeguard controls. Replacement part for Fireye systems
Fireye
Temperature sensor for use in HVAC and combustion systems. Monitors and controls temperature for burner management and flame safeguard controls. Replacement part for Fireye systems

More from Fireye

View all Fireye parts
Fireye
Fireye
PXMS-K Pressure Transmitter. The PXMS-K Series pressure transmitters, including models like the PXMS-200K, represent the pinnacle of modern pressure measurement technology. Designed to deliver superior performance and reliability, these state-of-the-art instruments are engineered for a wide range of industrial and commercial applications
FXIATS-140 Ambient Air Temperature Transmitter. The FXIATS-140 stands out as a premier solution for measuring ambient air temperature with unparalleled precision and reliability, even in the harshest environments. Designed for demanding HVAC, industrial, and commercial applications, this advanced temperature transmitter offers exceptional performance and durability
Fireye
FXIATS-140 Ambient Air Temperature Transmitter. The FXIATS-140 stands out as a premier solution for measuring ambient air temperature with unparalleled precision and reliability, even in the harshest environments. Designed for demanding HVAC, industrial, and commercial applications, this advanced temperature transmitter offers exceptional performance and durability
TS350 & TS752 Temperature Sensors. The BLPS, TS350 and TS752 series of pressure and temperature sensors are designed for use with the Nexus PPC4000 fuel air ratio controller and BurnerLogiX burner management system with integrated boiler control
Fireye
TS350 & TS752 Temperature Sensors. The BLPS, TS350 and TS752 series of pressure and temperature sensors are designed for use with the Nexus PPC4000 fuel air ratio controller and BurnerLogiX burner management system with integrated boiler control
NXIATS Ambient Air Temperature Sensor. The Fireye NXIATS Ambient Air Temperature Sensor is designed for reliable and accurate measurement of ambient air temperature in industrial combustion and control systems. It seamlessly integrates with the Fireye PPC6000 and NX6100 burner management systems via a Fireye-specific CANbus interface, ensuring optimal performance and data accuracy. This optional sensor enhances system functionality by providing real-time temperature monitoring, helping improve efficiency, safety, and compliance with environmental regulations
Fireye
NXIATS Ambient Air Temperature Sensor. The Fireye NXIATS Ambient Air Temperature Sensor is designed for reliable and accurate measurement of ambient air temperature in industrial combustion and control systems. It seamlessly integrates with the Fireye PPC6000 and NX6100 burner management systems via a Fireye-specific CANbus interface, ensuring optimal performance and data accuracy. This optional sensor enhances system functionality by providing real-time temperature monitoring, helping improve efficiency, safety, and compliance with environmental regulations
NX102x Gas Pressure Sensors. The NX102x Gas Pressure Sensor is an essential component for the NX6100 system, specifically designed to provide accurate and reliable gas pressure measurements in various industrial applications. Engineered for optimal performance, this sensor ensures that your gas monitoring systems operate effectively and safely
Fireye
NX102x Gas Pressure Sensors. The NX102x Gas Pressure Sensor is an essential component for the NX6100 system, specifically designed to provide accurate and reliable gas pressure measurements in various industrial applications. Engineered for optimal performance, this sensor ensures that your gas monitoring systems operate effectively and safely
NX104x Boiler Temperature Sensors. The Fireye NX104x Boiler Temperature Sensor is a high-quality temperature sensing device specifically designed for efficient monitoring and control in boiler systems. With a robust NEMA 4 protection level, this sensor is engineered to withstand harsh environmental conditions, making it an ideal choice for a variety of industrial applications. Proper conduit glands must be used to ensure optimal protection and performance
Fireye
NX104x Boiler Temperature Sensors. The Fireye NX104x Boiler Temperature Sensor is a high-quality temperature sensing device specifically designed for efficient monitoring and control in boiler systems. With a robust NEMA 4 protection level, this sensor is engineered to withstand harsh environmental conditions, making it an ideal choice for a variety of industrial applications. Proper conduit glands must be used to ensure optimal protection and performance
NX103x Steam Pressure Sensors. The NX103x Steam Pressure Sensor series is a vital component designed for accurate monitoring of steam pressure in various industrial applications. With multiple variants available, this sensor provides the flexibility needed to meet diverse operational requirements
Fireye