FBR FNDP 160/2 TC 2P SI is a two-stage heavy oil burner delivering 474–1900 kW thermal output with 42–165 kg/h fuel flow. Operating at IP 40 protection and 84.4–85.4 dBA, it serves industrial heating and combustion…

SKU 3G-FBR-00300

Brand
FBR
Item
FNDP 160/2 TC 2P SI
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

FBR
Weight
35 kg
stage
2 stages
fuel type
Heavy oil
nozzle mm
210
fan motor w
4
power kw max
1900
power kw min
474
flow kg h max
165
flow kg h min
42
ip protection
IP 40
noisiness dba
84.4-85.4
pump motor kw
0.55
electrical supply
3
power supply info
- 50Hz
current absorption a
7.45
thermal power mcal h
407/776-1600
nominal electric power w
17
max combustion air temp c
60

Datasheet Content

HEAVY-OIL BURNERS TWO STAGES SK072029_A_en FNDP 130/2 EVO - FNDP 160/2 Burners for heavy-oil two stages with: die-cast aluminum body, fan at high pressurisation, combustion head with adjustment at high efficiency and high flame stability and hydraulic system of regulation combustive air on the two stages of flame. Disposition rationalized of the components with accessibility facilitated for operations of setting and maintenance. Complete of flange and gasket for installation on generator, nozzles, flexible pipes, line filter electrically heated and equipped with thermostat. Available in versions with 2-pole or 4-pole pump motor. Fig. FNDP 160/2 FNDP 130/2 EVO - FNDP 160/2 HEAVY-OIL BURNERS TWO STAGES SK072029_A_en TECHNICAL DATA FNDP 130/2 EVO - FNDP 160/2 MODEL FNDP 130/2 EVO FNDP 160/2 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 34/64-137 42/80-165 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 330/621-1329 407/776-1600 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 380/730-1542 474/900-1900 Fuel: HEAVY-OIL MAX 20°E at 50°C Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 14 17 Fan motor [kW] 2.2 4 Pump motor (2-pole version) [kW] 0.55 0.55 Pump motor (4-pole version) [kW] 0.75 0.75 Nominal current absorption [A] 4.35 7.45 Nominal fan motor current absorption [A] 4.35 7.45 Nominal pump motor current absorption [A] 1.32 1.32 Nominal auxiliary absorption [A] 0.8 0.8 Resistances [kW] 11 12 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP฀40 Noisiness ** min-max [dBA] 82-83 84.4-85.4 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonourous pressure in the combustion lab, with funcional burner on beta boiler in a distance of 1 m (UNI EN ISO 3746). FNDP 130/2 EVO - FNDP 160/2 HEAVY-OIL BURNERS TWO STAGES SK072029_A_en OPERATING RANGE DIAGRAM [mbar] 16 FNDP 130/2 EVO 14 12 10 8 6 4 2 0 200 400 600 800 1000 1200 1400 1600 [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. [mbar] 16 FNDP 160/2 14 12 10 8 6 4 2 0 200 400 600 800 1000 1200 1400 1600 1800 2000 [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. FNDP 130/2 EVO - FNDP 160/2 HEAVY-OIL BURNERS TWO STAGES SK072029_A_en DIMENSIONS [MM] 40 183 F 320 D 320 N E A B TC - TL C1 - C2 * Fig. Dimensions MODEL A B C1 C2 * D E F N FNDP 130/2 EVO 460 407 960 1545 209 510 211 20 FNDP 160/2 460 407 960 1545 209 510 211 20 * Overall dimension with the burner out in position of maintenance. BOILER PLATE ** Suggested dimension of connection between burner and generator. Fig. Boiler plate MODEL L min L max M N min N** N max FNDP 130/2 EVO mm 340 368 M14 220 220 250 FNDP 160/2 mm 340 368 M14 220 220 250 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL *** FNDP 130/2 EVO mm 210 400 FNDP 160/2 mm 210 400 *** For different flame lengths, please contact our Technical-Sales Department. FNDP 130/2 EVO - FNDP 160/2 HEAVY-OIL BURNERS TWO STAGES SK072029_A_en PRODUCT SPECIFICATION PRODUCT SPECIFICATION Heavy-oil burners two stages. DETAILED SPECIFICATION Heavy-oil burners two stages,฀composed by: • Die-cast aluminum body; • Fan at high pressurisation, at reverse blades for FNDP 130/2 EVO; • Combustion head with adjustment at high performance and elevated flame stability; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Photodiode for flame detection; • IP 40 electric protection level; • Supports and tierods for burner extraction; • Easy extraction of combustion head without get off the burners by bolier; • Pump controlled by dedicated electric motor; available in 2-pole or 4-pole version; • Safety air pressure switch to stop the burner in lock-out (by stopping the pump motor) in case of failed or anomalous fan operation; • Thermostats for regulating: temperature of 1st resistance group, temperature of 2nd resistance group, minimum temperature. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive MAC; • 2014/68/EU (art.4, par.3) Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment) STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter electrically heated and equipped with a thermostat; • Isomart gasket; • Nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise protection. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products FNDP 130/2 EVO - FNDP 160/2
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR FNDP 160/2 TC 2P SI is a two-stage heavy oil burner delivering 474–1900 kW thermal output with 42–165 kg/h fuel flow. Operating at IP 40 protection and 84.4–85.4 dBA, it serves industrial heating and combustion applications requiring dual-stage efficiency.

Frequently Asked Questions

What is the FBR FNDP 160/2 TC 2P SI heavy oil burner used for?

The FBR FNDP 160/2 TC 2P SI is a two-stage heavy oil burner designed for industrial heating and combustion applications. It delivers 474–1900 kW thermal output with 42–165 kg/h fuel flow, making it suitable for boilers and generators requiring dual-stage efficiency in commercial and industrial settings.

What are the specifications of the FBR FNDP 160/2 TC 2P SI?

The FBR FNDP 160/2 TC 2P SI has a 2-stage heavy oil burner with 474–1900 kW thermal power, 42–165 kg/h fuel flow, IP 40 protection, and 84.4–85.4 dBA noise. It includes a 4 kW fan motor, 0.55 kW pump motor, 7.45 A current absorption, and operates on 3~400V, 50Hz power supply.

Where to buy the FBR FNDP 160/2 TC 2P SI in Singapore?

You can order the FBR FNDP 160/2 TC 2P SI heavy oil burner through 3G Electric in Singapore. We source and deliver this industrial burner, handling logistics, customs clearance, and delivery to your facility. Contact us for availability and lead time on this FBR model.

How to install and maintain the FBR FNDP 160/2 TC 2P SI burner?

Install the FBR FNDP 160/2 TC 2P SI using the supplied flange and gasket on the generator. Ensure the combustion air temperature does not exceed 60 °C. For maintenance, access the rationalized components for easy adjustment and cleaning of the hydraulic system and combustion head, following FBR's guidelines.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FNDP 160/2 TC 4P SI
FBR
FNDP 160/2 TC 4P SI
FNDP 160/2 TL 2P SI
FBR
FNDP 160/2 TL 2P SI
FNDP 160/2 TL 4P SI
FBR
FNDP 160/2 TL 4P SI
FNDP 100/2 TC SI
FBR
FNDP 100/2 TC SI
FNDP 160/M TC 4P SA
FBR
FNDP 160/M TC 4P SA
FNDP 70/2 TC SI
FBR
FNDP 70/2 TC SI

More from FBR

View all FBR parts
FNDP 100/2 TC
FBR
FNDP 100/2 TC
FBR
FBR
FNDP 750/M TL MEC
FBR
FBR
FNDP 250/M TL MEC
FBR
FBR
FNDP 450/M TL MEC
FBR
FBR
FNDP 350/M TL MEC
FBR
FBR
FNDP 150/M TL
FNDP 125/2 TC
FBR
FNDP 125/2 TC
FBR
FBR
FNDP 190/M TL MEC