Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

FBR G X5 24V - Burners & Combustion
FBRBurners & Combustion

FBR G X5 24V

The FBR G X5 24V is an industrial burner designed for heating applications, delivering 142–356 kW across a fuel flow range of 12–30 kg/h. Operating on single-phase 24 VDC electrical supply with a 215 mm nozzle, it…

SKU 3G-FBR-00114

Brand
FBR
Item
G X5 24V
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

FBR
nozzle mm
215
power kw max
356
power kw min
142
flow kg h max
30
flow kg h min
12
electrical supply
1

Datasheet Content

LIGHT-OIL BURNERS TWO STAGE SK070065_B_en G X4/2 - G X5/2 Light-oil burners two stage. They are composed by: two nozzles, aluminium frame, protection cover with noise reduction plate, combustion head with micro adjustment at high efficiency and high flame stability, hydraulic system of regulation combustive air on the two stages of flame. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Complete of connector 7 poles, flange and gasket for installation on boiler, nozzles, flexible pipes, line filter. Fig. 1 G X4/2 Fig. 2 G X5/2 G X4/2 - G X5/2 LIGHT-OIL BURNERS TWO STAGE SK070065_B_en TECHNICAL DATA G X4/2 - G X5/2 MODEL G X4/2 G X5/2 Flow 1°st. / min. 2°st. - max. 2°st. * [kg/h] 8/12-25 8.5/15-33.7 Thermal power 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 82/122-255 87/153-344 Thermal power 1°st. / min. 2°st. - max. 2°st. * [kW] 95/142-296 101/178-400 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stage Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [W] 300 600 Fan motor [W] 250 450 Nominal current absorption [A] 1.6 2.7 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness min. - max. ** [db(A)] 68-69 71-72 Burner weight *** [kg] 15.5 25 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the combustion laboratory, with burner on operation on beta boiler to 1m of distance (UNI EN ISO 3746). *** For burner with cover in steel (F) please add 1 kg to the weight. OPERATING RANGE DIAGRAM G X4/2 - G X5/2 [mbar] 10 9 8 7 6 5 4 3 2 G X4/2 G X5/2 1 0 -1 80 120 160 200 240 280 320 360 400 [kW] Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. G X4/2 - G X5/2 LIGHT-OIL BURNERS TWO STAGE SK070065_B_en DIMENSIONS [MM] Fig. 4 Dimensions G X4/2 - G X5/2 MODEL A B C D E F G H I G X4/2 182 192 318 124 306 248 17 200 200 G X5/2 210 218 400 130 461 310 18 200 200 * See "flame tube length" BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 5 Boiler plate MODEL L min L* L max M N min N* N max G X4/2 mm 170 205 226 M10 130 140 160 G X5/2 mm 205 220 226 M10 140 150 180 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** G X4/2 mm 130 250 G X5/2 mm 215 335 ** For different flame lengths, please contact our Technical-Sales Department. G X4/2 - G X5/2 LIGHT-OIL BURNERS TWO STAGE SK070065_B_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners two stage. DETAILED SPECIFICATION Light-oil burner two stage composed by: • Aluminium frame; • Combustion head with micro adjustment at high efficiency and high flame stability; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Photoresistance for flame detection; • IP 40 electric protection level; • Hydraulic system of regulation combustive air on the two stages of flame. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. G X4/2 - G X5/2

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR G X5 24V is an industrial burner designed for heating applications, delivering 142–356 kW across a fuel flow range of 12–30 kg/h. Operating on single-phase 24 VDC electrical supply with a 215 mm nozzle, it suits medium to large-scale combustion systems requiring modulating capacity.

Frequently Asked Questions

What is the FBR G X5 24V gas burner used for?

The FBR G X5 24V is a two-stage light-oil burner for medium to large-scale heating applications. It delivers 142–356 kW and is suitable for industrial boilers, furnaces, and combustion systems requiring modulating capacity. Common in Singapore's manufacturing and process-heat sectors.

What are the specifications of the FBR G X5 24V burner?

The FBR G X5 24V burner has a thermal power range of 142–356 kW, fuel flow 12–30 kg/h, a 215 mm nozzle, and operates on single-phase 24 VDC supply. It features two-stage operation, an aluminium frame, and a combustion head with micro adjustment for high flame stability.

Where to buy the FBR G X5 24V burner in Singapore?

You can source the FBR G X5 24V burner through 3G Electric, an established industrial equipment distributor since 1990. We handle logistics, customs clearance, and delivery to Singapore, providing local technical support for your combustion system needs.

How to install the FBR G X5 24V burner?

Installation should follow the manufacturer's manual and local regulations. Mount the burner using the supplied flange and gasket, connect the 7-pole connector and flexible oil pipes, and ensure the combustion chamber dimensions comply with EN267 standards. 3G Electric can advise on best practices.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
G X3 24V
FBR
G X3 24V
G X4 24V
FBR
G X4 24V
GAS X5/M CE TL EL | Variant: GPL | Subgroup: Burner
FBR
GAS X5/M CE TL EL | Variant: GPL | Subgroup: Burner
GAS X5/M CE TC EL | Variant: GPL | Subgroup: Burner
FBR
GAS X5/M CE TC EL | Variant: GPL | Subgroup: Burner
FBR
FBR
GAS X5 CE F
X GAS X5 CE TL | Variant: metano | Subgroup: Burner
FBR
X GAS X5 CE TL | Variant: metano | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL