OEM Heating cord with thermostat 2m 40W/m
The OEM Heating cord with thermostat 2m 40W/m (SKU 3G-CBM-01072) is a silicone-insulated anti-freeze heating cable with a bimetal thermostat set to activate between +3°C ± 3°C and +8°C ± 3°C, used to protect pipes…
SKU 3G-CBM-01072
Also listed as: 40 WM · 40-WM
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Need installation or engineering help?
Ask a question
Product Description
The OEM Heating cord with thermostat 2m 40W/m (SKU 3G-CBM-01072) is a silicone-insulated anti-freeze heating cable with a bimetal thermostat set to activate between +3°C ± 3°C and +8°C ± 3°C, used to protect pipes and prevent freezing in refrigeration and hydraulic systems. It operates at 220/240 V with a power output of 80 W/m, a 2000 mm heating section, a 1000 mm cold section, a total length of 2000 mm, and an outer diameter of 5.5 mm. The cord is supplied pre-cut to length and ready for use; the length cannot be shortened by the end user. Manufactured and tested to EN60335, with conformity to Directive 2014/35/UE and CE certification available.
Frequently Asked Questions
What is the OEM heating cord with thermostat 2m 40W/m used for?
It is a silicone-insulated heating cord with an integrated bimetallic thermostat, used for pipe freeze protection and to prevent freezing of refrigeration equipment and hydraulic networks. The thermostat switches the circuit on only at low temperature, saving energy.
What are the specifications of the OEM heating cord 40WM?
The OEM 40WM cord delivers 80 W/m over a 2000 mm heating section with a 1000 mm cold section (3000 mm total length), operates at 220/240 V, has a 5.5 mm outer diameter, silicone insulation, a 15 mm minimum bending radius, and a thermostat setpoint of +3°C ± 3°C to +8°C ± 3°C.
How should the OEM heating cord with thermostat be installed?
The cord is supplied cut to length and ready to use; the cable length cannot be shortened by the end user. Observe the 15 mm minimum bending radius and the -40°C to +130°C service temperature. It is manufactured and tested to EN60335 and conforms to Directive 2014/35/UE, with CE certification available.
Where to buy the OEM heating cord 40WM worldwide?
3G Electric supplies the OEM 40WM heating cord worldwide, handling logistics, customs and delivery. Contact us for lead time and availability; we source across 14 industrial departments and provide full commercial and technical support.
Used in
Common applications for OEMOEM Products
3G Electric supplies OEM hvac & refrigeration. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.