Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

IEC Supplementary Protector: 40 A Amps, 240V AC, 260 mA Rated Residual Current - UL1053 DIN Rail-Mount Ground Fault Protectors
IECUL1053 DIN Rail-Mount Ground Fault Protectors

IEC Supplementary Protector: 40 A Amps, 240V AC, 260 mA Rated Residual Current

The IEC Supplementary Protector is a UL1053 DIN Rail-Mount Ground Fault Protector from the GFP series, rated for 40 A amps and 240V AC. It features a Curve Type A characteristic and a Max. AIR Rating of 1.5kA at 240V…

SKU 3G-OTH-20650

Brand
IEC
Item
Supplementary Protector: 40 A Amps, 240V AC, 260 mA Rated Residual Current
Category
UL1053 DIN Rail-Mount Ground Fault Protectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

IEC
Manufacturer Part Number
M9R84440
Series
GFP
Type
260 mA Rated Residual Current, A, 1.5kA at 240V AC
AC
240V
Curve Type
A
Max. AIR Rating
1.5kA at 240V AC
AC Voltage Rating
240V AC

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

IEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The IEC Supplementary Protector is a UL1053 DIN Rail-Mount Ground Fault Protector from the GFP series, rated for 40 A amps and 240V AC. It features a Curve Type A characteristic and a Max. AIR Rating of 1.5kA at 240V AC, with a 260 mA Rated Residual Current (MPN M9R84440). This device provides ground fault protection for industrial electrical systems.

Frequently Asked Questions

What is the IEC Supplementary Protector M9R84440 used for?

The IEC Supplementary Protector M9R84440 is a UL1053 DIN Rail-Mount Ground Fault Protector from the GFP series. It provides ground fault protection for industrial electrical systems, detecting leakage currents as low as 260 mA to prevent equipment damage and shock hazards in 240V AC circuits.

What are the specifications of the IEC Supplementary Protector M9R84440?

The IEC Supplementary Protector M9R84440 is rated for 40 A amps at 240V AC, with a Curve Type A characteristic and a Max. AIR Rating of 1.5kA at 240V AC. It has a 260 mA Rated Residual Current and is part of the GFP series. This UL1053 device is designed for DIN rail mounting.

Where to buy the IEC Supplementary Protector M9R84440 worldwide?

You can source the IEC Supplementary Protector M9R84440 from 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time on this GFP series ground fault protector.

How to install the IEC Supplementary Protector M9R84440?

Install the IEC Supplementary Protector M9R84440 on a standard DIN rail in your panel. Ensure the circuit is de-energized before mounting. Connect line and load conductors per the wiring diagram, respecting the 240V AC rating and 40 A ampacity. Test the device after installation to verify ground fault protection.

Used in

Common applications for IEC
Industrial panelboards — IEC FAZ-C series 4-pole miniature circuit breakers for branch circuit protection in 480 V AC distribution
Motor control centers — IEC FAZ-C series MCBs for overcurrent protection of motor circuits in C-curve applications
Heating equipment — IEC GFP series ground fault protectors (e.g., 25 A, 260 mA) for personnel protection in electric heaters
Pump systems — IEC GFP series (e.g., 63 A, 26 mA) for ground fault protection in industrial pump controls
Commercial building electrical rooms — IEC FAZ-C series breakers for lighting and receptacle circuits in 277/480 V AC systems
Machine tool disconnects — IEC FAZ-C series MCBs as supplementary protection in control panels for manufacturing equipment

IEC Products

3G Electric supplies IEC ul1053 din rail-mount ground fault protectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
IEC Supplementary Protector: 100 A Amps, 240V AC, 260 mA Rated Residual Current, A, 1.5kA at 240V AC (MPN M9R84491)
IEC
IEC Supplementary Protector: 100 A Amps, 240V AC, 260 mA Rated Residual Current, A, 1.5kA at 240V AC (MPN M9R84491)
IEC Supplementary Protector: 40 A Amps, 240V AC, 260 mA Rated Residual Current, A, 1.5kA at 240V AC (MPN M9R84240)
IEC
IEC Supplementary Protector: 40 A Amps, 240V AC, 260 mA Rated Residual Current, A, 1.5kA at 240V AC (MPN M9R84240)
IEC Supplementary Protector: 25 A Amps, 240V AC, 260 mA Rated Residual Current, A, 1.5kA at 240V AC (MPN M9R84225)
IEC
IEC Supplementary Protector: 25 A Amps, 240V AC, 260 mA Rated Residual Current, A, 1.5kA at 240V AC (MPN M9R84225)
IEC Supplementary Protector: 25 A Amps, 240V AC, 26 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R81225)
IEC
IEC Supplementary Protector: 25 A Amps, 240V AC, 26 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R81225)
IEC Supplementary Protector: 40 A Amps, 240V AC, 26 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R81440)
IEC
IEC Supplementary Protector: 40 A Amps, 240V AC, 26 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R81440)
IEC Supplementary Protector: 25 A Amps, 240V AC, 86 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R12425)
IEC
IEC Supplementary Protector: 25 A Amps, 240V AC, 86 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R12425)

More from IEC

View all IEC parts
IEC Supplementary Protector: 25 A Amps, 240V AC, 86 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R12225)
IEC
IEC Supplementary Protector: 25 A Amps, 240V AC, 86 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R12225)
IEC Supplementary Protector: 63 A Amps, 240V AC, 26 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R81263)
IEC
IEC Supplementary Protector: 63 A Amps, 240V AC, 26 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R81263)
IEC Supplementary Protector: 40 A Amps, 240V AC, 26 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R81240)
IEC
IEC Supplementary Protector: 40 A Amps, 240V AC, 26 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R81240)
IEC Supplementary Protector: 25 A Amps, 240V AC, 26 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R81425)
IEC
IEC Supplementary Protector: 25 A Amps, 240V AC, 26 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R81425)
IEC Supplementary Protector: 25 A Amps, 240V AC, 260 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R44225)
IEC
IEC Supplementary Protector: 25 A Amps, 240V AC, 260 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R44225)
IEC Supplementary Protector: 63 A Amps, 240V AC, 26 mA Rated Residual Current, A, 1.5kA at 240V AC (MPN M9R81463)
IEC
IEC Supplementary Protector: 63 A Amps, 240V AC, 26 mA Rated Residual Current, A, 1.5kA at 240V AC (MPN M9R81463)
IEC Supplementary Protector: 25 A Amps, 240V AC, 260 mA Rated Residual Current, A, 1.5kA at 240V AC (MPN M9R84425)
IEC
IEC Supplementary Protector: 25 A Amps, 240V AC, 260 mA Rated Residual Current, A, 1.5kA at 240V AC (MPN M9R84425)
IEC Supplementary Protector: 25 A Amps, 277V AC, 26 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R41225)
IEC
IEC Supplementary Protector: 25 A Amps, 277V AC, 26 mA Rated Residual Current, A, 10kA at 240V AC (MPN M9R41225)