Send a part number, a photo, or a whole BOM — we supply it and stand behind it. EXW Singapore — collect from our office.

3G Electric
IEC GFP M9R84440 UL1053 DIN Rail-Mount Ground Fault Protector - UL1053 DIN Rail-Mount Ground Fault Protectors
IECUL1053 DIN Rail-Mount Ground Fault Protectors

IEC GFP M9R84440 UL1053 DIN Rail-Mount Ground Fault Protector

The IEC Supplementary Protector is a UL1053 DIN Rail-Mount Ground Fault Protector from the GFP series, rated for 40 A amps and 240V AC. It features a Curve Type A characteristic and a Max. AIR Rating of 1.5kA at 240V…

SKU 3G-OTH-20650

Brand
IEC
Item
GFP M9R84440 UL1053 DIN Rail-Mount Ground Fault Protector
Part Number
M9R84440
Category
UL1053 DIN Rail-Mount Ground Fault Protectors
Available to Order
Also known as:M9R84440IEC
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.

Technical Specifications

IEC
Manufacturer Part Number
M9R84440
Series
GFP
Type
260 mA Rated Residual Current, A, 1.5kA at 240V AC
AC
240V
Curve Type
A
Max. AIR Rating
1.5kA at 240V AC
AC Voltage Rating
240V AC

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

IEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The IEC Supplementary Protector is a UL1053 DIN Rail-Mount Ground Fault Protector from the GFP series, rated for 40 A amps and 240V AC. It features a Curve Type A characteristic and a Max. AIR Rating of 1.5kA at 240V AC, with a 260 mA Rated Residual Current (MPN M9R84440). This device provides ground fault protection for industrial electrical systems.

Frequently Asked Questions

What is the IEC Supplementary Protector M9R84440 used for?

The IEC Supplementary Protector M9R84440 is a UL1053 DIN Rail-Mount Ground Fault Protector from the GFP series. It provides ground fault protection for industrial electrical systems, detecting leakage currents as low as 260 mA to prevent equipment damage and shock hazards in 240V AC circuits.

What are the specifications of the IEC Supplementary Protector M9R84440?

The IEC Supplementary Protector M9R84440 is rated for 40 A amps at 240V AC, with a Curve Type A characteristic and a Max. AIR Rating of 1.5kA at 240V AC. It has a 260 mA Rated Residual Current and is part of the GFP series. This UL1053 device is designed for DIN rail mounting.

Where to buy the IEC Supplementary Protector M9R84440 worldwide?

You can source the IEC Supplementary Protector M9R84440 from 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time on this GFP series ground fault protector.

How to install the IEC Supplementary Protector M9R84440?

Install the IEC Supplementary Protector M9R84440 on a standard DIN rail in your panel. Ensure the circuit is de-energized before mounting. Connect line and load conductors per the wiring diagram, respecting the 240V AC rating and 40 A ampacity. Test the device after installation to verify ground fault protection.

Used in

Common applications for IEC
Industrial control panels — IEC FAZ-C20/4-NA 4-pole MCB for branch-circuit overcurrent protection in 277/480V AC systems.
Machinery ground fault protection — IEC GFP series 25 A, 240V AC, 26 mA residual current model for equipment-level fault detection.
Commercial electrical distribution — IEC GFP series 40 A, 240V AC, 260 mA residual current protector for feeder ground fault protection.
OEM equipment panels — IEC FAZ series C-curve MCB for inductive load protection in 4-pole configurations.
Panel retrofit projects — IEC GFP series 63 A, 240V AC, 26 mA residual current device for updated ground fault protection.
Power distribution units — IEC GFP series 25 A, 277V AC, 26 mA residual current protector with 10 kA interrupting capacity.
Not sure this is the right part? Photo-identify it→

IEC Products

3G Electric supplies IEC ul1053 din rail-mount ground fault protectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from IEC

View all IEC parts →

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first