Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

KDR LINE REACTORS Input Line Reactor: UL Type 1, High Z, 1 hp Max Output Power, 600V AC - Input Line Reactors
KDR LINE REACTORSInput Line Reactors

KDR LINE REACTORS Input Line Reactor: UL Type 1, High Z, 1 hp Max Output Power, 600V AC

The KDR LINE REACTORS Input Line Reactor: UL Type 1 (MPN KDRMA45H1E01) is a High Z, 2.1 A Output Current - Max reactor rated for 600V AC and 1 hp Max Output Power. This UL Type 1 enclosed unit is designed for input…

SKU 3G-OTH-622482

Brand
KDR LINE REACTORS
Item
Input Line Reactor: UL Type 1, High Z, 1 hp Max Output Power, 600V AC
Category
Input Line Reactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

KDR LINE REACTORS
Manufacturer Part Number
KDRMA45H1E01
Type
High Z, 2.1 A Output Current - Max
AC
600V
Max Output Power
1 hp

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

KDR LINE REACTORS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The KDR LINE REACTORS Input Line Reactor: UL Type 1 (MPN KDRMA45H1E01) is a High Z, 2.1 A Output Current - Max reactor rated for 600V AC and 1 hp Max Output Power. This UL Type 1 enclosed unit is designed for input line conditioning in industrial motor drive applications.

Frequently Asked Questions

What is a KDR LINE REACTORS input line reactor used for?

A KDR LINE REACTORS input line reactor, such as the KDRMA45H1E01, conditions incoming AC power to industrial motor drives. It reduces harmonics, limits voltage spikes, and protects drive components from electrical noise, ensuring reliable operation in manufacturing, HVAC, and pumping systems.

What are the specifications of the KDRMA45H1E01 line reactor?

The KDRMA45H1E01 is a UL Type 1 enclosed, High Z input line reactor rated for 600V AC, 2.1 A output current max, and 1 hp max output power. It is designed for industrial motor drive applications requiring robust line conditioning and harmonic mitigation.

Where to buy KDR LINE REACTORS worldwide?

3G Electric supplies KDR LINE REACTORS like the KDRMA45H1E01 to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this UL Type 1 input line reactor.

How to select the right input line reactor for a motor drive?

Select an input line reactor by matching its voltage rating (e.g., 600V AC), current rating (e.g., 2.1 A), and impedance type (e.g., High Z) to your motor drive's specifications. The KDRMA45H1E01 is suitable for 1 hp drives. Always consult the drive manual and consider harmonic reduction needs.

KDR LINE REACTORS Products

3G Electric supplies KDR LINE REACTORS input line reactors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from KDR LINE REACTORS

View all KDR LINE REACTORS parts
This input line reactor is designed for use with variable frequency drives and motor systems to reduce harmonics, limit inrush current, and smooth voltage spikes. Rated for 575/600V AC, 50 hp max output power, and 165 W watts loss, it is a High Z type with UL Type 1 enclosure
KDR LINE REACTORS
This input line reactor is designed for use with variable frequency drives and motor systems to reduce harmonics, limit inrush current, and smooth voltage spikes. Rated for 575/600V AC, 50 hp max output power, and 165 W watts loss, it is a High Z type with UL Type 1 enclosure
Open-style input line reactor for three-phase AC power systems. Rated 575/600V AC, 130 A maximum output current, 125 hp maximum output power. High impedance design reduces harmonic distortion, voltage spikes, and line notching in motor drive applications
KDR LINE REACTORS
Open-style input line reactor for three-phase AC power systems. Rated 575/600V AC, 130 A maximum output current, 125 hp maximum output power. High impedance design reduces harmonic distortion, voltage spikes, and line notching in motor drive applications
Open-style low-impedance input line reactor rated for 125 hp max output power at 208/240V AC with 377 A max output current. Used to protect variable frequency drives and power electronics from harmonics, voltage spikes, and current distortion in industrial motor control and power transmission systems
KDR LINE REACTORS
Open-style low-impedance input line reactor rated for 125 hp max output power at 208/240V AC with 377 A max output current. Used to protect variable frequency drives and power electronics from harmonics, voltage spikes, and current distortion in industrial motor control and power transmission systems
Open-style low impedance input line reactor rated for 100 hp max output power at 208/240V AC, with a maximum output current of 280 A. Designed to protect variable frequency drives and motor controllers from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, and pump systems
KDR LINE REACTORS
Open-style low impedance input line reactor rated for 100 hp max output power at 208/240V AC, with a maximum output current of 280 A. Designed to protect variable frequency drives and motor controllers from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, and pump systems
High Z input line reactor for AC motor drives, rated 25 hp at 460/480V AC with 112 W power loss. Provides harmonic filtering and surge protection to reduce power line disturbances in industrial motor systems
KDR LINE REACTORS
High Z input line reactor for AC motor drives, rated 25 hp at 460/480V AC with 112 W power loss. Provides harmonic filtering and surge protection to reduce power line disturbances in industrial motor systems
This input line reactor is designed for use with variable frequency drives and motor systems to mitigate power surges and harmonics. Rated for 575/600V AC with a maximum output current of 32 A and maximum output power of 30 hp, it features a Low Z design and UL Type 1 enclosure. Typical applications include industrial automation, HVAC, and pump installations
KDR LINE REACTORS
This input line reactor is designed for use with variable frequency drives and motor systems to mitigate power surges and harmonics. Rated for 575/600V AC with a maximum output current of 32 A and maximum output power of 30 hp, it features a Low Z design and UL Type 1 enclosure. Typical applications include industrial automation, HVAC, and pump installations
Low Z input line reactor rated for 575/600V AC, 0.75 hp max output power, 10.9 W watts loss. Used to protect variable frequency drives and motor controllers from power line harmonics and voltage spikes, smoothing current draw and reducing electrical noise in industrial automation, HVAC, and pump systems
KDR LINE REACTORS
Low Z input line reactor rated for 575/600V AC, 0.75 hp max output power, 10.9 W watts loss. Used to protect variable frequency drives and motor controllers from power line harmonics and voltage spikes, smoothing current draw and reducing electrical noise in industrial automation, HVAC, and pump systems
High impedance input line reactor for variable frequency drives and motor controllers. Rated 0.75 hp max output power at 208/240V AC with 12.9 W power loss. Reduces harmonics and voltage spikes in industrial automation, HVAC, and pumping systems
KDR LINE REACTORS
High impedance input line reactor for variable frequency drives and motor controllers. Rated 0.75 hp max output power at 208/240V AC with 12.9 W power loss. Reduces harmonics and voltage spikes in industrial automation, HVAC, and pumping systems