Send a part number, a photo, or a whole BOM — we supply it and stand behind it. EXW Singapore — collect from our office.

3G Electric
KDR LINE REACTORS Input Line Reactor, High Z, 750 A, 600 hp, 460/480V AC - Input Line Reactors
KDR LINE REACTORSInput Line Reactors

KDR LINE REACTORS Input Line Reactor, High Z, 750 A, 600 hp, 460/480V AC

The KDR LINE REACTORS Input Line Reactor: Open (SKU KDRULS1H, MPN KDRULS1H) is a High Z, 750 A Output Current - Max reactor designed for 460/480V AC systems with a 600 hp Max Output Power.

SKU 3G-OTH-622416

Brand
KDR LINE REACTORS
Item
Input Line Reactor, High Z, 750 A, 600 hp, 460/480V AC
Part Number
KDRULS1H
Category
Input Line Reactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. Bank transfer and corporate PO accepted.

Technical Specifications

KDR LINE REACTORS
Manufacturer Part Number
KDRULS1H
Type
High Z, 750 A Output Current - Max
AC
460/480V
Max Output Power
600 hp

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Ask a question

Request a Quote

Ask a question

KDR LINE REACTORS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The KDR LINE REACTORS Input Line Reactor: Open (SKU KDRULS1H, MPN KDRULS1H) is a High Z, 750 A Output Current - Max reactor designed for 460/480V AC systems with a 600 hp Max Output Power.

Frequently Asked Questions

What is a KDR line reactor used for?

A KDR line reactor protects variable frequency drives and other sensitive equipment from power line disturbances such as harmonics, spikes, and voltage transients. It smooths incoming current and reduces electrical noise in 460/480V AC industrial systems, extending equipment life in motor control applications.

What are the specifications of the KDRULS1H input line reactor?

The KDRULS1H is an open-style, high-impedance input line reactor rated for 460/480V AC systems. It delivers a maximum output current of 750 A and supports up to 600 hp maximum output power. This KDR LINE REACTORS component is designed for heavy-duty industrial motor drive protection.

Where to buy KDR line reactors worldwide?

3G Electric supplies the KDRULS1H input line reactor to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. As a global industrial solutions provider, we source genuine KDR LINE REACTORS components and support your procurement across 14 technical departments.

How to select the right input line reactor for a 460V drive?

Select a reactor with voltage matching your system (460/480V AC) and an amp rating at least equal to the drive's input current. For a 600 hp drive, the KDRULS1H at 750 A provides high impedance to limit harmonics. Always verify the reactor's impedance percentage and thermal rating with the drive manufacturer's guidelines.

Not sure this is the right part? Photo-identify it→

KDR LINE REACTORS Products

3G Electric supplies KDR LINE REACTORS input line reactors. We supply genuine products and their technical documentation.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

More from KDR LINE REACTORS

View all KDR LINE REACTORS parts →
This input line reactor is designed for use with variable frequency drives and motor controllers to mitigate power line harmonics, surges, and voltage spikes. Rated for 208/240V AC, 12 A output current, and 3 hp maximum output power, it is suitable for 3-phase systems in industrial automation and HVAC applications
KDR LINE REACTORS
This input line reactor is designed for use with variable frequency drives and motor controllers to mitigate power line harmonics, surges, and voltage spikes. Rated for 208/240V AC, 12 A output current, and 3 hp maximum output power, it is suitable for 3-phase systems in industrial automation and HVAC applications
Open-style low-impedance input line reactor rated for 575/600V AC, 32 A maximum output current, and 30 hp maximum output power. Used with variable frequency drives and motor controllers to reduce harmonics, voltage spikes, and current distortion in industrial motor-drive applications
KDR LINE REACTORS
Open-style low-impedance input line reactor rated for 575/600V AC, 32 A maximum output current, and 30 hp maximum output power. Used with variable frequency drives and motor controllers to reduce harmonics, voltage spikes, and current distortion in industrial motor-drive applications
Low-impedance input line reactor for variable frequency drives and motor controllers. Rated 460/480V AC, 720 A maximum output current, 600 hp maximum output power. Open-style construction. Reduces harmonics, voltage spikes, and current distortion in industrial automation, HVAC, pumping, and conveyor systems
KDR LINE REACTORS
Low-impedance input line reactor for variable frequency drives and motor controllers. Rated 460/480V AC, 720 A maximum output current, 600 hp maximum output power. Open-style construction. Reduces harmonics, voltage spikes, and current distortion in industrial automation, HVAC, pumping, and conveyor systems
This open-style input line reactor is designed for 575/600V AC systems with a maximum output current of 4.8 A and a maximum output power of 3 hp. It features low impedance construction to reduce harmonics, voltage spikes, and current distortion in motor drive applications. Typical uses include protecting variable frequency drives and motors in industrial automation, HVAC, and pumping systems
KDR LINE REACTORS
This open-style input line reactor is designed for 575/600V AC systems with a maximum output current of 4.8 A and a maximum output power of 3 hp. It features low impedance construction to reduce harmonics, voltage spikes, and current distortion in motor drive applications. Typical uses include protecting variable frequency drives and motors in industrial automation, HVAC, and pumping systems
High Z input line reactor for 460/480V AC systems, rated for 20 hp maximum output power with 108 W watts loss. Used in motor drive applications to reduce harmonics, limit inrush current, and smooth voltage spikes
KDR LINE REACTORS
High Z input line reactor for 460/480V AC systems, rated for 20 hp maximum output power with 108 W watts loss. Used in motor drive applications to reduce harmonics, limit inrush current, and smooth voltage spikes
This input line reactor is a High Z type rated for 600V AC, 2.1 A maximum output current, and 1 hp maximum output power. It is enclosed in a UL Type 1 housing for indoor use. The reactor conditions incoming AC power to motor drives, reducing harmonics and limiting voltage spikes
KDR LINE REACTORS
This input line reactor is a High Z type rated for 600V AC, 2.1 A maximum output current, and 1 hp maximum output power. It is enclosed in a UL Type 1 housing for indoor use. The reactor conditions incoming AC power to motor drives, reducing harmonics and limiting voltage spikes
This input line reactor is a High Z type rated for 575/600V AC with a maximum output power of 0.5 hp and 1.5 W watts loss. It is used to protect variable-frequency drives and motor controllers from power-line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, and pump systems
KDR LINE REACTORS
This input line reactor is a High Z type rated for 575/600V AC with a maximum output power of 0.5 hp and 1.5 W watts loss. It is used to protect variable-frequency drives and motor controllers from power-line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, and pump systems
Open-style high-impedance input line reactor rated for 460/480V AC, 540 A maximum output current, and 450 hp maximum output power. Used in motor drive systems to reduce harmonic distortion and protect against voltage spikes and current surges
KDR LINE REACTORS
Open-style high-impedance input line reactor rated for 460/480V AC, 540 A maximum output current, and 450 hp maximum output power. Used in motor drive systems to reduce harmonic distortion and protect against voltage spikes and current surges

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first