Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

MERSEN ATDR17-1/2 Time-Delay Cylindrical Fuse - Time-Delay Cylindrical Fuses
MERSENTime-Delay Cylindrical Fuses

MERSEN ATDR17-1/2 Time-Delay Cylindrical Fuse

The MERSEN ATDR Series ATDR17-1/2 is a 17.5 A, 600 V AC time-delay cylindrical fuse with a dual-element design and melamine body. It is non-indicating, measures 13/32 in x 1 1/2 in, and is intended for branch circuit…

SKU 3G-OTH-772757

Also listed as: ATDR1712 · ATDR17 1 2 · ATDR17-1-2

Brand
MERSEN
Item
ATDR17-1/2 Time-Delay Cylindrical Fuse
Category
Time-Delay Cylindrical Fuses
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

MERSEN
Manufacturer Part Number
ATDR17-1/2
Series
ATDR
Type
Time-Delay, 17.5 A, Non-Indicating, 13/32 in x 1 1/2 in
AC
600 V
Element
Dual
Body Material
Melamine
Fuse Applications
Branch Circuit Protection
Compatible Fuse Block Series
USFMCC

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

MERSEN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The MERSEN ATDR Series ATDR17-1/2 is a 17.5 A, 600 V AC time-delay cylindrical fuse with a dual-element design and melamine body. It is non-indicating, measures 13/32 in x 1 1/2 in, and is intended for branch circuit protection. This fuse is compatible with the USFMCC fuse block series.

Frequently Asked Questions

What is the MERSEN ATDR17-1/2 fuse used for?

The MERSEN ATDR17-1/2 is a 17.5 A, 600 V AC time-delay cylindrical fuse designed for branch circuit protection. Its dual-element design handles temporary inrush currents, making it suitable for motor and equipment circuits in industrial plants, HVAC systems, and power distribution panels.

What are the specifications of the MERSEN ATDR17-1/2 fuse?

The MERSEN ATDR17-1/2 is a 17.5 A, 600 V AC time-delay fuse with a dual-element design and melamine body. It is non-indicating, measures 13/32 in x 1 1/2 in, and is part of the ATDR series. It is compatible with the USFMCC fuse block series for branch circuit protection.

Where to buy the MERSEN ATDR17-1/2 fuse worldwide?

3G Electric supplies the MERSEN ATDR17-1/2 fuse worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for a quote and lead time on this branch circuit protection fuse.

How to select the correct MERSEN ATDR fuse for branch circuit protection?

To select the correct MERSEN ATDR fuse, match the voltage rating (600 V AC) and current rating (17.5 A) to your circuit requirements. Ensure the fuse dimensions (13/32 in x 1 1/2 in) fit your fuse block, such as the USFMCC series. The dual-element design provides time-delay for motor start-ups.

Used in

Common applications for MERSEN
Power electronics protection — MERSEN A70Q series semiconductor fuses in variable frequency drives for motor control.
Surge protection for industrial panels — MERSEN STP480D07 SPDs in three-phase 480V AC distribution boards.
Control circuit overcurrent protection — MERSEN ATM series midget fuses in PLC and instrumentation cabinets.
Power distribution in manufacturing — MERSEN FSPDB4A finger-safe blocks in motor control centers for wire management.
DC bus protection in renewable energy — MERSEN A30QS series fuses in solar inverter DC inputs.
High-voltage semiconductor protection — MERSEN A70Q series fuses in welding equipment power supplies.
Not sure this is the right part? Photo-identify it

MERSEN Products

3G Electric supplies MERSEN time-delay cylindrical fuses. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from MERSEN

View all MERSEN parts
Class RK5 time-delay cylindrical fuse rated 1.25 A at 600 V AC and 600 V DC. Non-indicating design with time-delay characteristic for motor and equipment protection. Suitable for overcurrent protection in industrial control panels, HVAC systems, and pump controls
MERSEN
Class RK5 time-delay cylindrical fuse rated 1.25 A at 600 V AC and 600 V DC. Non-indicating design with time-delay characteristic for motor and equipment protection. Suitable for overcurrent protection in industrial control panels, HVAC systems, and pump controls
Time-delay midget fuse rated 6 A and 250 V AC, with dimensions 13/32 in x 1 1/2 in. Non-indicating design. Suitable for protecting circuits with inrush currents in control panels, motor starters, and lighting systems
MERSEN
Time-delay midget fuse rated 6 A and 250 V AC, with dimensions 13/32 in x 1 1/2 in. Non-indicating design. Suitable for protecting circuits with inrush currents in control panels, motor starters, and lighting systems
MERSEN GFN Series midget time-delay fuse rated 20 A at 32 V AC. Dimensions 13/32 in x 1 1/2 in. Indicating type for visual blown-fuse identification. Used in control panels and industrial equipment for overcurrent protection with tolerance to inrush currents
MERSEN
MERSEN GFN Series midget time-delay fuse rated 20 A at 32 V AC. Dimensions 13/32 in x 1 1/2 in. Indicating type for visual blown-fuse identification. Used in control panels and industrial equipment for overcurrent protection with tolerance to inrush currents
Class RK5, TR-R series time-delay fuse rated 2.5 A at 250 V AC and 250 V DC. Non-indicating cylindrical body. Designed for branch-circuit protection in motor circuits, control panels, and equipment with high inrush currents
MERSEN
Class RK5, TR-R series time-delay fuse rated 2.5 A at 250 V AC and 250 V DC. Non-indicating cylindrical body. Designed for branch-circuit protection in motor circuits, control panels, and equipment with high inrush currents
Time-delay cylindrical fuse from MERSEN GDG Series, rated 8 A and 250 V AC. Body dimensions 5.1 mm x 20.1 mm. Provides overcurrent protection in circuits with temporary inrush currents, such as control panels, motor circuits, and power supplies
MERSEN
Time-delay cylindrical fuse from MERSEN GDG Series, rated 8 A and 250 V AC. Body dimensions 5.1 mm x 20.1 mm. Provides overcurrent protection in circuits with temporary inrush currents, such as control panels, motor circuits, and power supplies
MERSEN A6D Series Class RK1 time-delay cylindrical fuse, rated 300 mA at 600 V AC and 600 V DC. Non-indicating design for overcurrent protection in industrial circuits, such as motor and transformer branch circuits where inrush currents occur
MERSEN
MERSEN A6D Series Class RK1 time-delay cylindrical fuse, rated 300 mA at 600 V AC and 600 V DC. Non-indicating design for overcurrent protection in industrial circuits, such as motor and transformer branch circuits where inrush currents occur
MERSEN GDG Series time-delay cylindrical fuse rated 2.5 A, 250 V AC. Physical dimensions are 5.1 mm x 20.1 mm. Designed for overcurrent protection in industrial equipment such as control panels, motor circuits, and power supplies where tolerance to inrush currents is required
MERSEN
MERSEN GDG Series time-delay cylindrical fuse rated 2.5 A, 250 V AC. Physical dimensions are 5.1 mm x 20.1 mm. Designed for overcurrent protection in industrial equipment such as control panels, motor circuits, and power supplies where tolerance to inrush currents is required
The MERSEN TR20R is a Class RK5 time-delay cylindrical fuse rated 20 A, 250 V AC and 160 V DC. It is part of the TR-R Series and is non-indicating. This fuse provides overcurrent protection for motor circuits, transformers, and lighting systems, allowing temporary inrush currents without nuisance opening
MERSEN
The MERSEN TR20R is a Class RK5 time-delay cylindrical fuse rated 20 A, 250 V AC and 160 V DC. It is part of the TR-R Series and is non-indicating. This fuse provides overcurrent protection for motor circuits, transformers, and lighting systems, allowing temporary inrush currents without nuisance opening