Siemens Line Volt Mechanical Tstat: 15° to 55°F, Steel, Fixed, 5°F
The SIEMENS Line Volt Mechanical Tstat is a freeze protection indoor single-stage control with a fixed 5°F differential and a temperature control range of 15° to 55°F. It features a DPST switch action (open/close on…
SKU 3G-OTH-67794
Need installation or engineering help?
Ask a question
Product Description
The SIEMENS Line Volt Mechanical Tstat is a freeze protection indoor single-stage control with a fixed 5°F differential and a temperature control range of 15° to 55°F. It features a DPST switch action (open/close on rise), operates at 120 to 240V AC, and includes a 20 ft capillary with a 20 ft x 1/8 in bulb. The steel enclosure houses this fixed-differential thermostat, model 134-1504.
Frequently Asked Questions
What is the SIEMENS 134-1504 line volt mechanical thermostat used for?
The SIEMENS 134-1504 is a freeze protection indoor single-stage control. It prevents pipes and equipment from freezing by activating heating systems when temperatures drop between 15° and 55°F. Common applications include warehouses, boiler rooms, and mechanical spaces requiring reliable low-temperature monitoring.
What are the specifications of the SIEMENS 134-1504 thermostat?
The SIEMENS 134-1504 features a DPST switch action (open/close on rise), fixed 5°F differential, and temperature control range of 15° to 55°F. It operates at 120 to 240V AC, has a 20 ft capillary with 20 ft x 1/8 in bulb, and a steel enclosure. The fixed differential ensures consistent freeze protection without adjustment.
Where to buy the SIEMENS 134-1504 thermostat worldwide?
3G Electric supplies the SIEMENS 134-1504 line volt mechanical thermostat worldwide. As a global industrial distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time; we source and deliver this freeze protection control to any country.
How to install the SIEMENS 134-1504 freeze protection thermostat?
Mount the steel enclosure on a vibration-free surface near the protected area. Route the 20 ft capillary bulb to sense air temperature at the coldest point. Wire the DPST switch per local codes for 120 to 240V AC loads. Set the dial between 15° and 55°F; the fixed 5°F differential activates heating on temperature drop.
Used in
Common applications for SiemensSiemens Products
3G Electric supplies Siemens freeze protection indoor single-stage controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.