Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Siemens Line Volt Mechanical Tstat: 35° to 45°F, Steel, Fixed, 12°F - Freeze Protection Indoor Single-Stage Controls
SiemensFreeze Protection Indoor Single-Stage Controls

Siemens Line Volt Mechanical Tstat: 35° to 45°F, Steel, Fixed, 12°F

The SIEMENS Line Volt Mechanical Tstat is a freeze protection indoor single-stage control with a fixed 12°F temperature differential and a control range of 35° to 45°F. It features a steel enclosure, SPDT switch…

SKU 3G-OTH-67818

Brand
Siemens
Item
Line Volt Mechanical Tstat: 35° to 45°F, Steel, Fixed, 12°F
Category
Freeze Protection Indoor Single-Stage Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

Siemens
Manufacturer Part Number
134-1511
Type
Steel, Fixed, 12°F
AC Volt
120 to 240V
Voltage
120 to 240V AC
Differential Type
Fixed
Enclosure Material
Steel
Switch Type/Action
SPDT, Open/Close on Rise
Temperature Differential
12°F
Temperature Control Range
35° to 45°F
Capillary Length/Bulb Diameter
4 ft Capillary, 20 ft x 1/8 in Bulb
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Siemens Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The SIEMENS Line Volt Mechanical Tstat is a freeze protection indoor single-stage control with a fixed 12°F temperature differential and a control range of 35° to 45°F. It features a steel enclosure, SPDT switch action (open/close on rise), and operates at 120 to 240V AC. The unit includes a 4 ft capillary and a 20 ft x 1/8 in bulb.

Frequently Asked Questions

What is the SIEMENS 134-1511 line volt mechanical thermostat used for?

The SIEMENS 134-1511 is a freeze protection indoor single-stage control. It prevents pipes and equipment from freezing by activating heating when temperatures drop between 35° and 45°F. Common applications include warehouses, boiler rooms, and mechanical spaces requiring reliable low-temperature safeguarding.

What are the specifications of the SIEMENS 134-1511 thermostat?

The SIEMENS 134-1511 features a fixed 12°F temperature differential, SPDT switch action (open/close on rise), and operates at 120 to 240V AC. It includes a 4 ft capillary with a 20 ft x 1/8 in bulb, a steel enclosure, and a temperature control range of 35° to 45°F.

Where to buy the SIEMENS 134-1511 thermostat worldwide?

3G Electric supplies the SIEMENS 134-1511 thermostat worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time; we source and deliver this freeze protection control to any country.

How to install the SIEMENS 134-1511 freeze protection thermostat?

Mount the steel enclosure securely in a dry indoor location. Connect the SPDT switch per the wiring diagram for 120 to 240V AC. Position the 20 ft bulb and 4 ft capillary along the protected pipe or area. Set the control range between 35° and 45°F. Always follow local electrical codes and the manufacturer's instructions.

Used in

Common applications for Siemens
District cooling plants — LME73 + RWF55 for condenser-water modulation
Inflight catering and food-processing steam boilers — LMG22 with SQN90 air-fuel cross-damper
Hospital steam-plant redundancy — LME41 with QRA2 UV flame detection for dual-fuel boilers
Semiconductor fab process heat — LME23 and SKP55 gas valves on hot-oil heater skids
Container-terminal reefer-deck heating — LMG22 retrofit onto legacy burner racks

Siemens Products

3G Electric supplies Siemens freeze protection indoor single-stage controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
SIEMENS Electric Surface Mounted Thermostat: Heat and Cool, 50° to 200°F (MPN 141-0522). Key specifications — Control Type: Screwdriver; Switch Type/Action: SPDT, Open/Close on Rise; Temperature Control Range: 50° to 200°F; Temperature Differential: 4°F; Voltage: 120 to 240V AC; Brand: SIEMENS.
Siemens
SIEMENS Electric Surface Mounted Thermostat: Heat and Cool, 50° to 200°F (MPN 141-0522). Key specifications — Control Type: Screwdriver; Switch Type/Action: SPDT, Open/Close on Rise; Temperature Control Range: 50° to 200°F; Temperature Differential: 4°F; Voltage: 120 to 240V AC; Brand: SIEMENS.
SIEMENS Line Volt Mechanical Tstat: Heat or Cool, Auto, 40° to 95°F, Concealed Dial/Exposed Dial (MPN 134-1084). Key specifications — Application: Heat or Cool; System Settings: Auto; Switch Type/Action: SPDT, Open/Close on Rise; Temperature Control Range: 40° to 95°F; Stages: 1H/1C; Voltage: 120 to 240V AC; Brand: SIEMENS; Control Type: Concealed Dial.
Siemens
SIEMENS Line Volt Mechanical Tstat: Heat or Cool, Auto, 40° to 95°F, Concealed Dial/Exposed Dial (MPN 134-1084). Key specifications — Application: Heat or Cool; System Settings: Auto; Switch Type/Action: SPDT, Open/Close on Rise; Temperature Control Range: 40° to 95°F; Stages: 1H/1C; Voltage: 120 to 240V AC; Brand: SIEMENS; Control Type: Concealed Dial.
Siemens
Siemens
SIEMENS Pneumatic Mechanical Thermostat: 45° to 85°F, Direct and Reverse, 192-209. Key specifications — Temperature Control Range: 45° to 85°F; Thermostat Action: Direct and Reverse; Brand: SIEMENS.
JOHNSON CONTROLS Line Volt Mechanical Tstat: 35° to 45°F, Steel, Fixed, 12°F, 24 to 277V AC Volt (MPN A11B-1C). Key specifications — Switch Type/Action: SPST, Close on Rise; Temperature Control Range: 35° to 45°F; Temperature Differential: 12°F; Voltage: 24 to 277V AC; Capillary Length/Bulb Diameter: 4 ft Capillary, 20 ft x 1/8 in Bulb; Brand: JOHNSON CONTROLS; Differential Type: Fixed; Enclosure Material: Steel.
JOHNSON CONTROLS
JOHNSON CONTROLS Line Volt Mechanical Tstat: 35° to 45°F, Steel, Fixed, 12°F, 24 to 277V AC Volt (MPN A11B-1C). Key specifications — Switch Type/Action: SPST, Close on Rise; Temperature Control Range: 35° to 45°F; Temperature Differential: 12°F; Voltage: 24 to 277V AC; Capillary Length/Bulb Diameter: 4 ft Capillary, 20 ft x 1/8 in Bulb; Brand: JOHNSON CONTROLS; Differential Type: Fixed; Enclosure Material: Steel.
JOHNSON CONTROLS Line Volt Mechanical Tstat: 35° to 45°F, Steel, Manual Reset, 12°F (MPN A11A-1C). Key specifications — Switch Type/Action: SPST, Close on Rise; Temperature Control Range: 35° to 45°F; Temperature Differential: 12°F; Voltage: 24 to 277V AC; Capillary Length/Bulb Diameter: 4 ft Capillary, 20 ft x 1/8 in Bulb; Brand: JOHNSON CONTROLS; Differential Type: Manual Reset; Enclosure Material: Steel.
JOHNSON CONTROLS
JOHNSON CONTROLS Line Volt Mechanical Tstat: 35° to 45°F, Steel, Manual Reset, 12°F (MPN A11A-1C). Key specifications — Switch Type/Action: SPST, Close on Rise; Temperature Control Range: 35° to 45°F; Temperature Differential: 12°F; Voltage: 24 to 277V AC; Capillary Length/Bulb Diameter: 4 ft Capillary, 20 ft x 1/8 in Bulb; Brand: JOHNSON CONTROLS; Differential Type: Manual Reset; Enclosure Material: Steel.
SIEMENS Line Volt Mechanical Thermostat: Surface Mount, Close on Rise/Open on Rise, 30 to 110°F (MPN 141-0520). Key specifications — Switch Action: Open on Rise; Temperature Control Range: 30 to 110°F; Temperature Differential: 3.5 to 14°F; Brand: SIEMENS.
Siemens
SIEMENS Line Volt Mechanical Thermostat: Surface Mount, Close on Rise/Open on Rise, 30 to 110°F (MPN 141-0520). Key specifications — Switch Action: Open on Rise; Temperature Control Range: 30 to 110°F; Temperature Differential: 3.5 to 14°F; Brand: SIEMENS.

More from Siemens

View all Siemens parts
SIEMENS Line Volt Mechanical Tstat: 35° to 45°F, Steel, Fixed, 12°F, 120 to 240V AC Volt (MPN 134-1510). Key specifications — Switch Type/Action: SPDT, Open/Close on Rise; Temperature Control Range: 35° to 45°F; Temperature Differential: 12°F; Voltage: 120 to 240V AC; Capillary Length/Bulb Diameter: 4 ft Capillary, 20 ft x 1/8 in Bulb; Brand: SIEMENS; Differential Type: Fixed; Enclosure Material: Steel.
Siemens
SIEMENS Line Volt Mechanical Tstat: 35° to 45°F, Steel, Fixed, 12°F, 120 to 240V AC Volt (MPN 134-1510). Key specifications — Switch Type/Action: SPDT, Open/Close on Rise; Temperature Control Range: 35° to 45°F; Temperature Differential: 12°F; Voltage: 120 to 240V AC; Capillary Length/Bulb Diameter: 4 ft Capillary, 20 ft x 1/8 in Bulb; Brand: SIEMENS; Differential Type: Fixed; Enclosure Material: Steel.
SIEMENS Line Volt Mechanical Tstat: 15° to 55°F, Steel, Fixed, 5°F, 120 to 240V AC Volt (MPN 134-1504). Key specifications — Switch Type/Action: DPST, Open/Close on Rise; Temperature Control Range: 15° to 55°F; Temperature Differential: 5°F; Voltage: 120 to 240V AC; Capillary Length/Bulb Diameter: 20 ft Capillary, 20 ft x 1/8 in Bulb; Brand: SIEMENS; Differential Type: Fixed; Enclosure Material: Steel.
Siemens
SIEMENS Line Volt Mechanical Tstat: 15° to 55°F, Steel, Fixed, 5°F, 120 to 240V AC Volt (MPN 134-1504). Key specifications — Switch Type/Action: DPST, Open/Close on Rise; Temperature Control Range: 15° to 55°F; Temperature Differential: 5°F; Voltage: 120 to 240V AC; Capillary Length/Bulb Diameter: 20 ft Capillary, 20 ft x 1/8 in Bulb; Brand: SIEMENS; Differential Type: Fixed; Enclosure Material: Steel.