Siemens Molded Case Circuit Breaker: 30 A Amps, 10kA at 120V AC, Fixed, Load Side Lug
The SIEMENS Molded Case Circuit Breaker is an ED-Frame, ED2-series device rated for 30 A amps with a maximum AIR rating of 10kA at 120V AC. It features a fixed instantaneous trip and a load-side lug terminal…
SKU 3G-OTH-21777
Need installation or engineering help?
Ask a question
Product Description
The SIEMENS Molded Case Circuit Breaker is an ED-Frame, ED2-series device rated for 30 A amps with a maximum AIR rating of 10kA at 120V AC. It features a fixed instantaneous trip and a load-side lug terminal connection, supporting any phase connection. This breaker is identified by manufacturer part number ED21B030.
Frequently Asked Questions
What is the Siemens ED21B030 molded case circuit breaker used for?
The Siemens ED21B030 is an ED-frame, ED2-series molded case circuit breaker rated for 30 A. It protects electrical circuits from overloads and short circuits in commercial and industrial power distribution panels, switchboards, and motor control centers. Its fixed instantaneous trip and load-side lug terminals suit branch-circuit protection.
What are the specifications of the Siemens ED21B030 circuit breaker?
The Siemens ED21B030 is a 30 A molded case circuit breaker with a maximum AIR rating of 10kA at 120V AC. It features a fixed instantaneous trip, load-side lug terminal connection, and supports any phase connection. It belongs to the ED2 series and is identified by MPN ED21B030.
Where to buy the Siemens ED21B030 circuit breaker worldwide?
3G Electric supplies the Siemens ED21B030 molded case circuit breaker worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time. We source genuine Siemens components for commercial and industrial applications.
How to select the correct Siemens molded case circuit breaker for an application?
To select the correct Siemens molded case circuit breaker, verify the continuous current rating (e.g., 30 A), available fault current (AIR rating, e.g., 10kA at 120V AC), and system voltage. Confirm the frame type (ED2), trip characteristics (fixed instantaneous), and terminal connections (load-side lug). Always consult a licensed electrician for proper coordination.
Used in
Common applications for SiemensSiemens Products
3G Electric supplies Siemens ed-frame siemens molded case circuit breakers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.