Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
AllansonUV Ballasts

Allanson UVB148T6-1800-MV UV Ballast – Program Start

3G-OTH-03010 UV BALLAST – Program Start

SKU 3G-OTH-03010

Also listed as: UVB148T61800MV · UVB148T6 1800 MV

Brand
Allanson
Item
UVB148T6-1800-MV UV Ballast – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Size
11.75″x3.2″x1.78″
Lamps
1
Weight
5.3 lb
Lamp mA
1800
Lamp Type
Amalgam
Input Lamps
1
Lamp Length
20" to 48"
Potted Case
Yes
Input Voltage
120V-240V
Input Wattage
155

Datasheet Content

[{"filename":"UVB148T6-1800-MV_WEB.pdf","text":"Specifications Guide\n UVB Ballasts\nUVB148T6-1800-MV\n Lamp Type /Catalog # Manufacturer Power (W) Current (A)\n\n NNI 80/61 Heraeus 120 1.8\n\n\n\n\n Amalgam\n NNI 80/36 U Heraeus 115 1.5\n NNI 120/44 U Heraeus 125 1.5\n GPHVA1000T6L Light Sources 150 1.8\n GPHVA843T6L Light Sources 127 1.8\n TUV115W VHO Philips 115 1.8\n\n\n\nBallast Specifications\nBallast type: Program Start (PS) Operating frequency: > 25kHz\nNumber of lamps: 1 Lamp current crest factor: 1.7 or less\nNormal input voltage: 120-240V, +/-10%, 50/60 Hz Power factor: > 95%\nInput current: 1.32A(120V)/0.70A(240V) Efficiency: > 90%\nInput power: 155W @ full load Ambient temperature: 0-40ºC\nApprovals: UL/cUL Listed, Case maximum temperature: 75ºC\n Class “P”, Outdoor, Type 1 Sound rating: “A”\n Weight: 5.20 lbs\n\n\nWiring Diagram and Dimensions\n\n\n\n\n 83 Commerce Valley Drive East, Markham, ON L3T 7T3 Canada\n www.allanson.com | cservice@allanson.com | T: 1.800.668.9162 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03010 UV BALLAST – Program Start

Frequently Asked Questions

What is the Allanson 3G-OTH-03010 UV ballast used for?

The Allanson 3G-OTH-03010 is a program-start UV ballast designed to power single amalgam UV lamps, such as Heraeus NNI 80/61 or Philips TUV115W VHO, in water treatment, air purification, and industrial disinfection systems.

What are the specifications of the Allanson 3G-OTH-03010?

The Allanson 3G-OTH-03010 ballast operates at 120-240 VAC, 50/60 Hz, with 155 W input power and 1.8 A lamp current. It supports one amalgam lamp, measures 11.75" x 3.2" x 1.78", weighs 5.3 lb, and is UL/cUL listed with a Type 1 outdoor rating.

Where to buy the Allanson 3G-OTH-03010 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03010 UV ballast to Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this program-start ballast for amalgam lamps.

How to install the Allanson 3G-OTH-03010 ballast?

Install the Allanson 3G-OTH-03010 in a dry, ventilated area within 0-40 °C ambient temperature. Connect input voltage (120-240 VAC) per the wiring diagram, ensure proper grounding, and match lamp type (e.g., Heraeus NNI 80/61) for program-start operation.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB148T6-2200-MV UV Ballast – Program Start
Allanson
Allanson
Allanson UVB248T6-1800-MV UV Ballast – Program Start
Allanson
Allanson
Allanson UVB248T6-2200-MV UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120T6-1800-MV UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDD UV Ballast – Program Start
Allanson
Allanson
Allanson UVB248T6-2200-MV-PCB UV Ballast – Program Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start