Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
AllansonUV Ballasts

Allanson UVB248T6-1800-MV UV Ballast – Program Start

3G-OTH-03023 UV BALLAST – Program Start

SKU 3G-OTH-03023

Also listed as: UVB248T61800MV · UVB248T6 1800 MV

Brand
Allanson
Item
UVB248T6-1800-MV UV Ballast – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Size
16.57″x3.2″x2.73″
Lamps
2
Weight
8.75 lb
Lamp mA
1800
Lamp Type
Amalgam
Input Lamps
2
Lamp Length
20" to 48"
Potted Case
Yes
Input Voltage
120V-240V
Input Wattage
310

Datasheet Content

[{"filename":"UVB248T6-1800-MV_WEB.pdf","text":"Specifications Guide\n UVB Ballasts\nUVB248T6-1800-MV\n Lamp Type /Catalog # Manufacturer Power (W) Current (A)\n\n NNI 80/61 Heraeus 120 1.8\n\n\n\n\n Amalgam\n NNI 80/36 U Heraeus 115 1.5\n NNI 120/44 U Heraeus 125 1.5\n GPHVA1000T6L Light Sources 150 1.8\n GPHVA843T6L Light Sources 127 1.8\n TUV115W VHO Philips 115 1.8\n\n\n\nBallast Specifications\nBallast type: Program Start (PS) Operating frequency: > 25kHz\nNumber of lamps: 2 Lamp current crest factor: 1.7 or less\nNormal input voltage: 120-240V, +/-10%, 50/60 Hz Power factor: > 95%\nInput current: 2.65A(120V)/1.40A(240V) Efficiency: > 90%\nInput current THD: < 10% Ambient temperature: 0-40ºC\nInput power: 310W @ full load Case maximum temperature: 75ºC\nApprovals: UL/cUL Listed, Sound rating: “A”\n Class “P”, Outdoor, Type 1 Weight: 8.75 lbs\n\n\nWiring Diagram and Dimensions\n\n\n\n 2.729\"\n\n\n\n\n 16.573\"\n\n 15.947\"\n\n\n\n\n 3.200\" 2.000\"\n\n\n\n\n 33 Cranfield Road, Toronto, ON M4B 3H2\n www.allanson.com | cservice@allanson.com | T: 1.800.661.7251 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03023 UV BALLAST – Program Start

Frequently Asked Questions

What is the Allanson 3G-OTH-03023 UV ballast used for?

The Allanson 3G-OTH-03023 is a program-start UV ballast designed to power two amalgam UV lamps, such as Heraeus NNI 80/61 or Philips TUV115W VHO. It is commonly used in water treatment, air purification, and industrial UV curing systems where reliable lamp ignition and stable output are required.

What are the specifications of the Allanson 3G-OTH-03023?

The Allanson 3G-OTH-03023 operates at 120-240 VAC, 50/60 Hz, with 310W input power and 1800 mA lamp current. It drives two amalgam lamps from 20 to 48 inches. The ballast measures 16.57 x 3.2 x 2.73 inches, weighs 8.75 lb, and carries UL/cUL, Class P, and Type 1 outdoor approvals.

Where to buy the Allanson 3G-OTH-03023 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03023 UV ballast to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact our team for a quotation and lead time on this program-start ballast.

How to install the Allanson 3G-OTH-03023 ballast?

Mount the Allanson 3G-OTH-03023 in a dry, ventilated area within 0-40°C ambient temperature. Connect input voltage (120-240 VAC) per the wiring diagram, ensuring proper grounding. Use the correct lamp type and length (20-48 inches) for program-start operation. Do not exceed the case temperature limit of 75°C.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB248T6-2200-MV UV Ballast – Program Start
Allanson
Allanson
Allanson UVB148T6-1800-MV UV Ballast – Program Start
Allanson
Allanson
Allanson UVB148T6-2200-MV UV Ballast – Program Start
Allanson
Allanson
Allanson UVB248T6-2200-MV-PCB UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120T6-1800-MV UV Ballast – Program Start
Allanson
Allanson
Allanson UVB264T6-2100-MV-PCB UVB248T6-2100-MV-PCB UV Ballast – Program Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start