Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
AllansonUV Ballasts

Allanson UVB50W-120-240V-TA UV Ballast – Program Start

3G-OTH-03044 UV BALLAST – Program Start

SKU 3G-OTH-03044

Also listed as: UVB50W120240VTA · UVB50W 120 240V TA

Brand
Allanson
Item
UVB50W-120-240V-TA UV Ballast – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Size
5.0″x3.0″x1.32″
Lamps
1 to 2
Weight
1.1 lb
Lamp mA
425
Lamp Type
Standard
Input Lamps
1 to 2
Lamp Length
13″ to 17″
Potted Case
Yes
Input Voltage
120V-240V
Input Wattage
50

Datasheet Content

[{"filename":"UVB50W-120-240V-TA_WEB.pdf","text":"> 95%\nSpecifications Guide > 90%\n EOL/OC\n timer, buzzer,\n reset switch, LEDs\n\nUVB50W-120-240V-TA 0-40ºC\n 75ºC\n “A”\n 1.10 lbs\n Lamp Type /Catalog # Manufacturer Power (W) Current (mA)\n\n ASIH1003 (17\") Ultravation 24 400\n ASIH1001 (12\") Ultravation 16 400\n TUV 25W 4P SE Philips 23 350\n GPH436T5VH/4 Heraeus 21 400\n GPH436T5L First Light 25 450\n GPH463T5L/4 Atlantic 23 425\n\n\nBallast Specifications\nBallast type: Program Start (PS) Power factor:\nNumber of lamps: 1 or 2 Efficiency:\nNormal input voltage: 120-240V, +/-10%, 50/60 Hz Ballast shut down/protection:\nInput current: 0.42A(120V)/0.22A(240V) Status indication/Alarm:\nInput current THD: < 10%\nInput power: 50W @ full load Ambient temperature:\nOperating frequency: > 25kHz Case maximum temperature:\nLamp current crest factor: 1.7 or less Sound rating:\nApprovals: UL/cUL Listed, Weight:\n Class “P”, Indoor, Type 1\n\nWiring Diagram and Dimensions\n\n\n\n\n 83 Commerce Valley Drive East, Markham, ON L3T 7T3 Canada\n www.allanson.com | cservice@allanson.com | T: 1.800.668.9162 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03044 UV BALLAST – Program Start

Frequently Asked Questions

What is the Allanson 3G-OTH-03044 UV ballast used for?

The Allanson 3G-OTH-03044 is a program-start UV ballast designed to power one or two standard UV lamps, such as those from Ultravation, Philips, Heraeus, or Atlantic. It is commonly used in water treatment, air purification, and industrial UV disinfection systems.

What are the specifications of the Allanson 3G-OTH-03044?

The Allanson 3G-OTH-03044 operates at 120-240 VAC, 50/60 Hz, with an input power of 50 W at full load. It supports 1 to 2 lamps with a lamp current of 425 mA, lamp lengths from 13 to 17 inches, and measures 5.0 x 3.0 x 1.32 inches. It is UL/cUL listed, Class P, indoor, Type 1.

Where to buy the Allanson 3G-OTH-03044 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03044 UV ballast to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this program-start ballast.

How to select the right UV ballast for my lamps?

To select the correct UV ballast, match the ballast's lamp current (mA) and lamp type to your lamp's specifications. The Allanson 3G-OTH-03044 is designed for standard UV lamps drawing 425 mA, such as the GPH436T5VH/4 from Heraeus or the GPH463T5L/4 from Atlantic. Always verify lamp length and wattage against the ballast's compatibility list.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB50W-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-120-240V-PD UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-24V-TA UV Ballast – Program Start
Allanson
Allanson
Allanson UVB80W-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100W-425-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V UV Ballast – Program Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start