Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
AllansonUV Ballasts

Allanson UVB50W-120-240V UV Ballast – Program Start

3G-OTH-03041 UV BALLAST – Program Start

SKU 3G-OTH-03041

Also listed as: UVB50W120240V · UVB50W 120 240V

Brand
Allanson
Item
UVB50W-120-240V UV Ballast – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Size
5.0″x2.4″x1.0″
Lamps
1 to 2
Weight
0.62 lb
Lamp mA
425
Lamp Type
Standard
Input Lamps
1 to 2
Lamp Length
13″ to 17″
Potted Case
Yes
Input Voltage
120V-240V
Input Wattage
50

Datasheet Content

[{"filename":"2.UVB50W-120-240V_WEB_07.22.pdf","text":"Specifications Guide\n UV Ballasts\nUVB50W-120-240V\n Lamp Type /Catalog # Manufacturer Power (W) Current (mA)\n\n ASIH1003 (17\") Ultravation 24 400\n ASIH1001 (12\") Ultravation 16 400\n TUV 25W 4P SE Philips 23 350\n GPH436T5VH/4 Heraeus 21 400\n GPH436T5L First Light 25 450\n GPH463T5L/4 Atlantic 23 425\n\n\nBallast Specifications\nBallast type: Program Start (PS) Operating frequency: > 25kHz\nNumber of lamps: 1 or 2 Lamp current crest factor: 1.7 or less\nNormal input voltage: 120-240V, +/-10%, 50/60 Hz Power factor: > 95%\nInput current: 0.42A(120V)/0.22A(240V) Efficiency: > 90%\nInput current THD: < 10% Ballast shut down/protection: EOL/OC\nInput power: 50W @ full load Ambient temperature: 0-40ºC\nApprovals: UL/cUL Listed, Case maximum temperature: 75ºC\n Class “P”, Indoor, Type 1 Sound rating: “A”\n Weight: 0.62 lbs\n\nWiring Diagram and Dimensions\n\n\n\n\n 5.000\"\n\n 4.650\"\n\n\n\n\n 2.400\" 0.375\"\n\n 1.000\"\n\n\n\n\n 83 Commerce Valley Drive East, Markham, ON L3T 7T3\n www.allanson.com | cservice@allanson.com | T: 1.800.661.7251 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03041 UV BALLAST – Program Start

Frequently Asked Questions

What is the Allanson 3G-OTH-03041 UV ballast used for?

The Allanson 3G-OTH-03041 is a program-start UV ballast designed to power one or two standard UV lamps, such as those used in water treatment, air purification, and industrial disinfection systems. It operates at 120-240V input and supports lamp lengths from 13 to 17 inches.

What are the specifications of the Allanson 3G-OTH-03041 UV ballast?

The Allanson 3G-OTH-03041 ballast has an input voltage of 120-240V, input wattage of 50W, and supports 1 to 2 lamps at 425 mA. It measures 5.0 x 2.4 x 1.0 inches, weighs 0.62 lb, and is UL/cUL listed with a potted case for protection.

Where to buy the Allanson 3G-OTH-03041 UV ballast in Singapore?

3G Electric supplies the Allanson 3G-OTH-03041 UV ballast to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this program-start ballast.

How to install the Allanson 3G-OTH-03041 UV ballast?

To install the Allanson 3G-OTH-03041 ballast, ensure the input voltage matches your supply (120-240V). Connect the ballast to one or two standard UV lamps per the wiring diagram. Mount the potted case in a dry, indoor location with ambient temperature between 0-40°C.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB50W-120-240V-TA UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-120-240V-PD UV Ballast – Program Start
Allanson
Allanson
Allanson UVB80W-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100W-425-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB80WHO-120-240V UV Ballast – Program Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start