Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

SIT Nova gas block 0820055 - Gas Controls
SITGas Controls

SIT Nova gas block 0820055

Sit Nova gas block 0820055

SKU 3G-CBM-00405

Also listed as: BLO 05165 · BLO-05165

Brand
SIT
Item
Nova gas block 0820055
Category
Gas Controls
UNSPSC
40142201 — Gas regulators
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

SIT
type
multifunction gas control valve
control
On-Off gas flow

Datasheet Content

8 2 0 N O V A ENGLISH - ITALIANO - FRANCAIS - DEUTSCH - NEDERLANDS - ESPAÑOL - SVENSKA Read the instructions before use. This control must be installed in accordance with the rules in force. Leggere le istruzioni prima dell’uso. Questo controllo deve essere installato in accordo con le normative in vigore. Consultez les notices avant d’utiliser ce dispositif. Son installation doit répondre aux règles en vigueur. Lesen Sie die Instruktionen vor Inbetriebnahme. Dieser Regler muß nach den gültigen Vorschriften installiert werden. Lees de richtlijnen voor gebruik. Deze regelaar moet worden geinstalleerd in overeenstemming met de heersende voorschriften. Leer las instrucciones antes de usar este dispositivo. Este control debe ser instalado conforme a las normas en vigor. Läs instruktionerna före användning. Denna kontrollanordning måste installeras i enlighet med gällande föreskrifter. INSTRUCTIONS D’UTILISATION ET D’INSTALLATION F Vanne multifonctionnelle monocommande à contrôle On-Off du débit de gaz, adaptée pour une utilisation sur les chaudières, les appareils pour la restauration collective, les générateurs d’air chaud, les tubes radiants et les radiateurs. SIT 820 NOVA est disponible dans les versions à alimentation en courant alternatif (220/240 V ou 24 V) ou à alimentation par thermopile, permettant ainsi le contrôle intégral de l’appareil sans demander d’énergie électrique au réseau. Toutes les versions sont disponibles, sur demande, dans la version avec dispositif de contrôle manuel du débit de gaz. CARACTERISTIQUES PRINCIPALES Manette de commande trois positions : éteint, veilleuse, allumé (MS) Dispositif thermoélectrique de sécurité flamme avec verrouillage à réarmement manuel (GM) Electrovanne de régulation à fonctionnement silencieux (EV) Régulateur de pression de type servo (PR) Dispositif d’allumage ralenti (sur demande) (SO) Dispositif manuel de réglage du débit principal de gaz (sur demande) (MA) Sortie veilleuse avec vis de réglage du débit de gaz (RQ) Filtre d'entrée et veilleuse (FL) Prises de pression d'entrée et de sortie Entrée et sortie gaz filetées 1/2 avec prédisposition pour raccordement par bride Sortie pour le branchement du régulateur de pression à la chambre de combustion. SCHEMAS DE FONCTIONNEMENT Versions avec réglage du débit de gaz Versions avec dispositif manuel de réglage de type On-Off du débit de gaz GM EV GM EV FL MS PR SO FL MS ARRIVEE ARRIVEE PR MA SO GAZ BRULEUR GAZ BRULEUR PRINCIPAL PRINCIPAL BRULEUR BRULEUR VEILLEUSE VEILLEUSE FL RQ FL RQ SIT 820 NOVA mV SIT 820 NOVA ■ Electrovanne alimentée ■ Electrovanne alimentée par thermopile en courant alternatif DISPOSITIF DE REGLAGE MANUEL SIT 820 NOVA mV est également disponible dans les versions avec réglage manuel du débit de gaz. En faisant tourner la manette de réglage de la position HI à la position LO, on obtient une réduction du débit de gaz qui dépend des conditions d’utilisation. Réduction débit [%] Réduction du débit de gaz 50 en passant TH TP TP TH de la position HI à la 40 position LO LOT en fonction de la pression PI 30 de sortie Pu. 20 A 10 E 0 6 8 10 12 14 Pu [mbar] 16 DONNEES TECHNIQUES Les données techniques ci-dessous se réfèrent à la norme EN126 "Dispositifs multifonctionnels pour appareils à gaz". Raccordements gaz Rp 1/2 ISO 7 Position de montage indifférente Familles de gaz de fonctionnement I, II et III Pression maximale d’entrée gaz 60 mbar Plage d'étalonnage de la pression maximale de sortie 3…30 mbar (sur demande : 20…50 mbar ou 5…50 mbar) Température ambiante d'utilisation 0…70°C (sur demande : -20…60°C) Régulateur de pression Classe B Electrovanne de régulation Classe D (sur demande Classe C) Temps de fermeture standard <1s versions mV <5s Résistance à la flexion et à la torsion groupe 2 Dispositif de sécurité flamme (alimenté par thermocouples SIT série 200 ou 290) Temps d'allumage <10s Temps d'extinction <60s Nombre de cycles prévus 5.000 Dispositif de fermeture manuel Nombre de cycles prévus 5.000 DONNEES ELECTRIQUES VERSIONS ALIMENTEES EN COURANT ALTERNATIF VERSIONS mV Tension (C.A.) Consommation (mA) Classe D ou C Utiliser des thermopiles à deux fils 240 V 50 Hz 25 Tension avec circuit ouvert ≥ 350 mV 220 V 50 Hz 20 Tension avec circuit fermé ≥ 100 mV 220 V 60 Hz 25 Résistance de la bobine 1.6 Ω 24 V 50 Hz 210 24 V 60 Hz 220 Degré de protection électrique IP 54 en utilisant des connecteurs de type 160 avec vis et joint code 0.960.104 DÉBITS DE GAZ CLASSE D Q [m3/h d=0,6 classe D] I Famille (d = 0.45) Q = 7.5 m3/h ∆p = 5 mbar II Famille (d = 0.6) Q = 6.5 m3/h ∆p = 5 mbar 10 III Famille (d = 1.7) Q = 8.1 kg/h ∆p = 5 mbar 8 6 CLASSE C 4 I Famille (d = 0.45) Q = 5.3 m3/h ∆p = 5 mbar 2 II Famille (d = 0.6) Q = 4.6 m3/h ∆p = 5 mbar 0 III Famille (d = 1.7) Q = 5.8 kg/h ∆p = 5 mbar 5 10 Q [m 3 /h d=0,6 classe D] 12 10 8 2 Plage des pressions d’entrée 6 Courbe Type gaz 1 4 Nominale Max. Min. 2 1 2H 20 25 17 0 2 2L 25 30 20 5 10 15 Pu [mbar] 17 FONCTIONNEMENT Allumage de la veilleuse Appuyer sur la manette de commande et la faire tourner jusqu'à la position “veilleuse” . Appuyer sur la manette, et allumer la veilleuse en maintenant la manette toujours appuyée à fond durant quelques secondes (Fig.1). Relâcher la manette et vérifier que la veilleuse reste bien allumée (Fig.2). Dans le cas contraire, répéter les opérations d'allumage. Allumage du brûleur principal Appuyer sur la manette de commande et la faire tourner jusqu'à la position “allumé” (Fig.3). En alimentant l’électrovanne, le passage du gaz vers le brûleur principal est autorisé (Fig.4). Dans les versions avec dispositif manuel de réglage, la pression de sortie est déterminée par la position de la manette de réglage. Position de Stand by Pour tenir le brûleur principal fermé tout en conservant la veilleuse allumée, appuyer sur la manette de commande et la faire tourner sur la position “veilleuse” . Arrêt Appuyer sur la manette de commande et la faire tourner sur la position “Off” (Fig.5). ATTENTION: le dispositif de blocage avec réarmement empêche l’allumage de l'appareil durant tout le temps de sécurité nécessaire au dispositif de contrôle de flamme (environ 60s - Fig.5). A la fin de ce laps de temps, la fermeture du groupe magnétique permet le début de l’opération d’allumage (Fig.6). Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 18 INSTALLATION La vanne SIT 820 NOVA est conforme aux normes de sécurité en vigueur. L'installation sur les appareils doit toutefois être confrontée aux normes spécifiques concernant chaque installation. Il est en particulier…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SIT Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Sit Nova gas block 0820055

Frequently Asked Questions

What is the SIT Nova gas block 0820055 used for?

The SIT Nova gas block 0820055 is a multifunction gas control valve used in boilers, catering equipment, warm-air generators, radiant tubes, and heaters. It provides On-Off gas flow control with a three-position knob (off, pilot, on) and includes a thermoelectric flame safety device with manual reset.

What are the specifications of the SIT Nova gas block 0820055?

The SIT Nova gas block 0820055 is a multifunction gas control valve with On-Off gas flow control. It features a three-position control knob, thermoelectric flame safety device with manual reset, silent-operation solenoid valve, servo pressure regulator, and 1/2-inch threaded gas inlet/outlet with flange connection provision.

Where to buy the SIT Nova gas block 0820055 in Singapore?

3G Electric supplies the SIT Nova gas block 0820055 to Singapore. We handle logistics, customs clearance, and delivery to your site. Contact our team for pricing and lead time on this gas control valve. We provide technical support for industrial gas applications in Singapore.

How to install the SIT Nova gas block 0820055?

Install the SIT Nova gas block 0820055 in accordance with local regulations. Ensure the gas supply is off before connecting the 1/2-inch threaded inlet and outlet. Use the pressure taps for system checks. The three-position knob controls off, pilot, and main burner modes. Always follow the manufacturer's instructions.

Used in

Common applications for SIT
Commercial boiler gas-control replacement — Sigma 845 / 848 on hot-water and steam boilers
Catering and commercial kitchen equipment — Eurosit 630 thermostatic valves on fryers, ovens, and steamers
Residential heating appliance service — NOVA 820 / 822 / 824 as OEM-replacement gas-control valves
Standing-pilot gas appliance refurbishment — Eurosit 630 and Minisit thermostatic controls
Industrial gas-fired process equipment — Sigma 848 modulating gas valves for burner integration

SIT Products

3G Electric supplies SIT gas controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Nova gas block 0820052
SIT
Nova gas block 0820052
Nova gas block 0820012
SIT
Nova gas block 0820012
Gas block Nova 0820056
SIT
Gas block Nova 0820056
Gas block Nova 0820010
SIT
Gas block Nova 0820010
Gas block Nova 0822111
SIT
Gas block Nova 0822111
Gas block Nova 0822114
SIT
Gas block Nova 0822114

More from SIT

View all SIT parts
Pilot light 3 flames 0160005
SIT
Pilot light 3 flames 0160005
Pilot light 2 flames 0140024
SIT
Pilot light 2 flames 0140024
Pilot light 1 flame 0150073
SIT
Pilot light 1 flame 0150073
Pilot light 1 flame 0140039
SIT
Pilot light 1 flame 0140039
SIT
SIT
Connector with cable 830 0960107
SIT
SIT
Gas block Sigma 0848108
SIT
SIT
Minisit gas block 0710750
SIT
SIT
Intermediate contact M9 X 1