Dwyer CO2 detector Modbus CDTA-5E000
Dwyer CO2 detector CDTA-5E000 measures indoor air quality with CO2, humidity, and temperature monitoring via RS-485 Modbus RTU or BACnet MS/TP. CO2 accuracy of ±16 ppm and 2-minute response time ensure reliable HVAC…
SKU 3G-CBM-02248
Also listed as: DWY 34014 · DWY-34014
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
Dwyer CO2 detector CDTA-5E000 measures indoor air quality with CO2, humidity, and temperature monitoring via RS-485 Modbus RTU or BACnet MS/TP. CO2 accuracy of ±16 ppm and 2-minute response time ensure reliable HVAC control across 0 to +50°C environments.
Frequently Asked Questions
What is the Dwyer CDTA-5E000 CO2 detector used for?
The Dwyer CDTA-5E000 CO2 detector monitors indoor air quality by measuring CO2, humidity, and temperature. It is used in HVAC systems for demand-controlled ventilation, ensuring comfortable and energy-efficient environments in commercial buildings, schools, and offices across Singapore.
What are the specifications of the Dwyer CDTA-5E000?
The Dwyer CDTA-5E000 measures CO2 (0 to 2000 or 5000 ppm), humidity (10 to 95% RH), and temperature (0 to +50°C). It communicates via RS-485 Modbus RTU or BACnet MS/TP, with CO2 accuracy of ±16 ppm non-linearity and a 2-minute response time. Power supply is 10 to 30 VAC or 10 to 42 VDC.
Where to buy the Dwyer CDTA-5E000 in Singapore?
3G Electric supplies the Dwyer CDTA-5E000 CO2 detector to Singapore. We source this Dwyer product globally and handle logistics, customs clearance, and local delivery. Contact our team for pricing and lead time on orders.
How to install the Dwyer CDTA-5E000 CO2 detector?
Install the Dwyer CDTA-5E000 in a well-ventilated area away from direct airflow or heat sources. Set the RS-485 MAC address using the built-in DIP switches and select Modbus RTU or BACnet MS/TP protocol. Wire power (10 to 30 VAC or 10 to 42 VDC) and communication lines per the datasheet.
Used in
Common applications for DwyerDwyer Products
3G Electric supplies Dwyer measurement. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.