Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

DUNGS Ignition Transformers (US/CA) - Accessory
DungsAccessory

DUNGS Ignition Transformers (US/CA)

The DUNGS ignition transformers are used in commercial and industrial applications to ignite burners with a voltage of 6000 VAC.

SKU 3G-OTH-02863

Also listed as: IGNITIONTRANSFORMERSUSCA · IGNITION TRANSFORMERS US CA

Brand
Dungs
Item
Ignition Transformers
Category
Accessory
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Datasheet Content

[{"filename":"ignition-transformers_manual_us_261486.pdf","text":"Ignition Transformer\n Installation Instructions USA CDN\n\n\n\n\n Table of Contents\n Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . Page 1\n Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1\n Attention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1\n Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2\n Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 3\n Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . Page 3\n Installation and Wiring Instructions . . . . . . . . Page 3\n\n\n\n\n Approvals\n CSA Certified:\n Allanson CSA File # L744Z\n CSA 22.2 No. 13\n UL 506\n\n\n\n\n Attention\n The installation and maintenance On completion of installation on\n of this product must be done Safety the Ignition Transofrmer, perform\n under the supervision of an ex-\n perienced and trained specialist.\n first a function test.\n\n Never perform work if gas pres-\n sure or power is applied, or in\n the presence of an open flame.\n O.K.\n\n\n\n\n MC • Karl Dungs, Inc. • Ignition Transformer • Edition 2024.04 • P/N 261486 • Rev. -0\n Please read the instruction be- This product is intended for\n fore installing or operating. Keep IFGC installations covered by but not\n the instruction in a safe place. You CSA limited to NFPA 70, NFPA 79,\n find the instruction also at www. UL NFPA 85, NFPA 86, UL 795, CSD-\n dungs.com If these instructions ANSI 1, ANSI Z83.4, ANSI Z83.18, ANSI\n are not heeded, the result may NFPA Z21.13, and CSA B149.3.\n be personal injury or damage to\n property.\n\n\n\n\n Explanation of symbols\n 1, 2, 3 ... = Action\n • = Instruction\n1…3\n\fSpecification\nThis transformer is intended for industrial or commercial heating applications that use a 6000 VAC input spark ignitor to\nignite fuel at a burner. This product is an internally grounded, single pole electrode type ignition transformer.\n\n Electrical Input Rating Available/VA Ambient and Surface Mounting\n 120 VAC/50-60 Hz (+10%; -15%) °F Temperature\n +110\n 240 VAC/60Hz (+10%; -15%) +5 °F to +110 °F (-15 °C to +40 °C)\n 240 VAC/50 Hz (+10%; -15%) +5\n 0\n [V] [A] Amperage\n [Hz] [VA] Operation: 1.5 A input on the pri-\n mary. Inrush current for first 250\n milliseconds:\n 1) 8 A on first start (new out of the box)\n 2) 3 A on every start thereafter.\n\n\n\n\n Shipping Weight Mounting Position\n 10 lbs Any\n\n Grounding Electrical Connection on Primary\n This transformer is a signal elec- Leads with 1/2” opening for locknut.\n trode type and the primary is inter-\n nally grounded. If a separate primary\n ground wire is required, contact Karl\n Dungs for different models.\n\n\n\n\nPart Number Primary Secondary Allanson Input Current Input Current\n Voltage Voltage Type +/- 15 % @ 50 Hz +/- 15 % @ 60 Hz\n267344 120 V / 50 - 60 Hz 6,000 VAC 1092-S 1.60 0.50\n267343 240 V / 60 Hz 6,000 VAC 1112-S 0.60* 0.25\n267342 240 V / 50 Hz 6,000 VAC 1196-S 0.40 0.20*\n*Not recommended for operation at this frequency. The transformer may overheat, which will decrease the transformer‘s life.\n\n\n\n\n MC • Karl Dungs, Inc. • Ignition Transformer • Edition 2024.04 • P/N 261486 • Rev. -0\n\n\n\n\n 2…3\n\f Dimensions\n\n\n\n 1 5/16”\n\n\n\n\n 7/8” Dia\n 5 29/32”\n Knockouts\n 5 7/8” 6 3/4”\n\n\n\n\n Junction Box\n 1 1/4”\n Cover\n 3 7/8” 1/16” 4 7/16”\n\n\n Trouble Shooting\n • Resistance across L1 and L2 should be 2.5 Ohms.\n\n Installation and Wiring Instructions\n • Remove the protective paper on top of the transformer. Do not ground the secondary using a ground\n • Use UL Recognized GTO ignition cable or wire rated for wire. The secondary requires only one wire,\n the continous output voltage of the transformer. which is connected to a spark ignitor.\n • The secondary ignition GTO wire must not exceed 8 ft.\n…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dungs Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DUNGS ignition transformers are used in commercial and industrial applications to ignite burners with a voltage of 6000 VAC.

Frequently Asked Questions

What is the DUNGS ignition transformer used for?

The DUNGS ignition transformer is used in commercial and industrial heating applications to ignite fuel at a burner using a 6000 VAC input spark ignitor. It is an internally grounded, single pole electrode type transformer suitable for systems covered by standards such as NFPA 70, NFPA 85, and CSA B149.3.

What are the specifications of the DUNGS ignition transformer?

The DUNGS ignition transformer has electrical ratings of 120 VAC/50-60 Hz, 240 VAC/60 Hz, or 240 VAC/50 Hz, with a tolerance of +10%/-15%. It operates at 1.5 A input on the primary, with an inrush current of 8 A on first start and 3 A thereafter. Ambient temperature range is +5 °F to +110 °F (-15 °C to +40 °C). Shipping weight is 10 lbs.

Where to buy DUNGS ignition transformers in Singapore?

You can source DUNGS ignition transformers through 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on availability. We provide genuine DUNGS components for commercial and industrial burner applications.

How to install a DUNGS ignition transformer?

Installation must be done under the supervision of a trained specialist. Never work with gas pressure or power applied, or near an open flame. After installation, perform a function test. The transformer can be mounted in any position. Refer to the DUNGS installation instructions for wiring details and safety precautions.

Used in

Common applications for Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners

Dungs Products

3G Electric supplies Dungs accessory. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Dongan
Dongan
Dongan XD-DC212, single-phase ignition transformer
Dongan
Dongan
Dongan XD-BK204, single-phase ignition transformer
Dongan
Dongan
Dongan XD-UR200, single-phase ignition transformer
Dongan
Dongan
Dongan XD-AB207, single-phase ignition transformer
Dongan
Dongan
Dongan XD-AB201, single-phase ignition transformer
Dongan
Dongan
Dongan XD-WN209, single-phase ignition transformer

More from Dungs

View all Dungs parts
Dungs
Dungs
DUNGS SAV Limit Switch
Dungs
Dungs
DUNGS SAV Reed Contact
DUNGS SBO / CO - Gas Orifices (US/CA)
Dungs
DUNGS SBO / CO - Gas Orifices (US/CA)
DUNGS CPI 400 & Visual Indicator - Valve Position Indication & Valve Switch Visual Indicator (VI) (US/CA)
Dungs
DUNGS CPI 400 & Visual Indicator - Valve Position Indication & Valve Switch Visual Indicator (VI) (US/CA)
DUNGS VBS / VCW - Gas Venturi Meters (US/CA)
Dungs
DUNGS VBS / VCW - Gas Venturi Meters (US/CA)
DUNGS K01/1 - Closed Position Indicator switch for solenoid valves, double solenoid valves & GasMultiBloc®
Dungs
DUNGS K01/1 - Closed Position Indicator switch for solenoid valves, double solenoid valves & GasMultiBloc®
DUNGS PBV - Push Button Shutoff Valve (US/CA)
Dungs
DUNGS PBV - Push Button Shutoff Valve (US/CA)
DUNGS VI - Visual Indicator (US/CA)
Dungs
DUNGS VI - Visual Indicator (US/CA)