Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

DUNGS VBS / VCW - Gas Venturi Meters (US/CA) - Accessory
DungsAccessory

DUNGS VBS / VCW - Gas Venturi Meters (US/CA)

Dungs Accessory.

SKU 3G-OTH-02871

Also listed as: VBSVCWUSCA · VBS VCW US CA

Brand
Dungs
Item
VBS / VCW - Gas Venturi Meters
Category
Accessory
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Datasheet Content

[{"filename":"vbs-vcw_manual_us_261487.pdf","text":"VBS and VCW\n Gas Venturi Flow USA CDN\n Metering Device\n Installation Instructions\n\n\n Table of Contents\n Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . Page 1\n Attention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1\n Gas Venturi Flow Metering Device . . . . . . . . . . Page 2\n Sizing a Venturi . . . . . . . . . . . . . . . . . . . . . . . . . . Page 3\n Screwed Brass Venturi (VBS) . . . . . . . . . . . . . . Page 3\n Screwed Brass Venturi (VBS) . . . . . . . . . . . . . . Page 4\n Carbon Steel Venturi (VCW) . . . . . . . . . . . . . . . Page 5\n Carbon Steel Venturi (VCW) . . . . . . . . . . . . . . . Page 6\n Correction Factor Calculation . . . . . . . . . . . . . Page 6\n Installation of VBS Venturi . . . . . . . . . . . . . . . . Page 7\n\n\n\n\n Attention\n The installation and maintenance Check the ratings in the speci-\n of this product must be done fications to make sure that they\n under the supervision of an ex- are suitable for your application.\n perienced and trained specialist.\n Never perform work if gas pres- [V] [A]\n sure or power is applied, or in [Hz] [VA]\n the presence of an open flame.\n\n Please read the instruction be- On completion of work on the gas\n fore installing or operating. Keep Safety venturi meter, perform a leakage\n the instruction in a safe place. You\n first and function test.\n\n\n O.K.\n find the instruction also at www.\n dungs.com If these instructions\n are not heeded, the result may\n be personal injury or damage to\n property.\n Any adjustment and application- This product is intended for\n specific adjustment values must IFGC installations covered by, but\n be made in accordance with the CSA not limited to, the following\n appliance-/boiler manufacturers UL codes and standards: NFPA 70,\n instructions. ANSI NFPA 86, CSD-1, ANSI Z21.13,\n NFPA\n\n\n\n\n MC • Karl Dungs, Inc. • VBS & VCW Gas Venturi Meters • Edition 2025.05 • P/N 261487\n UL 795, NFPA 85, or CSA B149.3.\n\n\n\n\n Explanation of symbols\n 1, 2, 3 ...\t = Action\t\t\n • = Instruction\n1…7\n\f Gas Venturi Flow Metering Device\n• Permits accurate setting of burner air and gas flow for • One piece machined brass connection\n optimum efficiency. • Includes brass hex-head screws to plug holes when mea-\n• Lower pressure loss than plate type orifices; can reduce surements are not being taken.\n blower horsepower requirements. • Metal tag chained to orifice clearly shows orifice pipe size\n• +/- 1 % accuracy depending on lacation, measurement and part number.\n accuracy and proper use of correction factors.\n\nScrewed Venturi’s (VBS) Pipe Size Overall Length\n• Available from 1/2” 2 3/4”\n 1/2” - 2 1/2” NPT 3/4” 3”\n• Rated for 250 PSI\n 1” 3 3/4”\n• Brass construction\n• Max. temperature 1 1/4” (500) 4”\n rating 300 °F 1 1/4” (616) 3 3/4”\n 1 1/2” (505) 4 1/4”\n 1 1/2” (632) 4”\n 2” (485) 5”\n 2” (685) 4 1/4”\n 2 1/2” (608) 5 1/2”\n 2 1/2” (750) 5 1/4”\n\nWelded Venturi’s (VCW) Pipe Size Overall Length\n• Available from 2 1/2” (628) 4 5/8”\n 2 1/2” - 30” NPT 2 1/2” (746) 4”\n• Rated for 250 PSI\n 3” (623) 5 1/4”\n• Zinc plated construction\n• Ends are chamfered for 3” (745) 4 1/4”\n buttwelding to pipes 4” (555) 5 7/8”\n• Max. temperature 4” (674) 5 3/8”\n rating 300 °F\n 5” 5”\n 6” 6”\n 8” 7”\n 10” 8”\n 12” 12”\n 14” 14”\n 16” 26”\n\n\n\n\n MC • Karl Dungs, Inc. • VBS & VCW Gas Venturi Meters • Edition 2025.05 • P/N 261487\n 18” 29”\n 20” 32”\n 24” 39”\n 30” 48”\n\n\n\n\n 2…7\n\f Sizing a Venturi\n • Use the tables on pages 2 and 3 for sizing a threaded orifice. • Select the orifice by either pressure drop or by flow. Apply\n…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dungs Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Dungs Accessory.

Frequently Asked Questions

What is the DUNGS VBS / VCW gas venturi meter used for?

The DUNGS VBS and VCW gas venturi meters are metering devices used to accurately set burner air and gas flow for optimum efficiency in industrial gas-fired equipment. They offer lower pressure loss than plate-type orifices, which can reduce blower horsepower requirements.

What are the specifications of the DUNGS VBS / VCW gas venturi meter?

The DUNGS VBS is a screwed brass venturi, while the VCW is a carbon steel venturi. Both provide ±1% accuracy depending on location, measurement accuracy, and proper use. They include a metal tag showing orifice pipe size and part number, and brass hex-head screws to plug measurement holes when not in use.

Where to buy DUNGS VBS / VCW gas venturi meters in Singapore?

3G Electric supplies DUNGS VBS and VCW gas venturi meters to Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on these DUNGS-branded metering devices.

How to install a DUNGS VBS venturi meter?

Installation must be done by an experienced specialist. Ensure gas pressure and power are off before starting. After installation, perform a leakage and function test. Refer to the DUNGS instruction manual for detailed steps and follow the appliance manufacturer's guidelines.

Used in

Common applications for Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners

Dungs Products

3G Electric supplies Dungs accessory. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
This brass drum vent features a 2 in male NPS connection and a minimum opening pressure of 3 psi. It is used on drums to relieve internal pressure or vacuum, helping to prevent rupture or collapse during filling, emptying, or temperature changes
This brass drum vent features a 2 in male NPS connection and a minimum opening pressure of 3 psi. It is used on drums to relieve internal pressure or vacuum, helping to prevent rupture or collapse during filling, emptying, or temperature changes
This drum vent provides pressure and vacuum relief for drums storing petroleum chemicals. It features a 2-inch male NPS connection and a minimum opening pressure of 3 psi. The yellow polyethylene construction is suitable for vertical orientation on drum openings
This drum vent provides pressure and vacuum relief for drums storing petroleum chemicals. It features a 2-inch male NPS connection and a minimum opening pressure of 3 psi. The yellow polyethylene construction is suitable for vertical orientation on drum openings
This bronze drum vent provides pressure and vacuum relief for drums containing flammable and non-flammable liquids. It features a 2 in Male NPT connection and opens at a minimum of 5 psi to prevent drum rupture or collapse during storage, transport, or dispensing
This bronze drum vent provides pressure and vacuum relief for drums containing flammable and non-flammable liquids. It features a 2 in Male NPT connection and opens at a minimum of 5 psi to prevent drum rupture or collapse during storage, transport, or dispensing
This polyethylene drum vent features a male NPS 2-inch pipe size and a minimum opening pressure of 3 psi. It automatically relieves internal pressure or vacuum to prevent drum rupture or collapse while maintaining a seal under normal conditions. Suitable for use on drums storing petroleum chemicals
This polyethylene drum vent features a male NPS 2-inch pipe size and a minimum opening pressure of 3 psi. It automatically relieves internal pressure or vacuum to prevent drum rupture or collapse while maintaining a seal under normal conditions. Suitable for use on drums storing petroleum chemicals
This brass drum vent provides pressure and vacuum relief for drums containing petroleum chemicals. It features a 2 in male NPS connection and a minimum opening pressure of 3 psi, helping to prevent drum rupture or collapse during storage and transport
This brass drum vent provides pressure and vacuum relief for drums containing petroleum chemicals. It features a 2 in male NPS connection and a minimum opening pressure of 3 psi, helping to prevent drum rupture or collapse during storage and transport
Aluminum vacuum saving valve with 1/2 in G inlet, 27 mm hex size, and 41 mm overall length. Maintains vacuum pressure at 0.6 bar threshold. Used in pneumatic systems to prevent backflow and stabilize vacuum levels
AVENTICS
Aluminum vacuum saving valve with 1/2 in G inlet, 27 mm hex size, and 41 mm overall length. Maintains vacuum pressure at 0.6 bar threshold. Used in pneumatic systems to prevent backflow and stabilize vacuum levels

More from Dungs

View all Dungs parts
Dungs
Dungs
DUNGS SAV Limit Switch
Dungs
Dungs
DUNGS SAV Reed Contact
DUNGS SBO / CO - Gas Orifices (US/CA)
Dungs
DUNGS SBO / CO - Gas Orifices (US/CA)
DUNGS CPI 400 & Visual Indicator - Valve Position Indication & Valve Switch Visual Indicator (VI) (US/CA)
Dungs
DUNGS CPI 400 & Visual Indicator - Valve Position Indication & Valve Switch Visual Indicator (VI) (US/CA)
DUNGS Ignition Transformers (US/CA)
Dungs
DUNGS Ignition Transformers (US/CA)
DUNGS K01/1 - Closed Position Indicator switch for solenoid valves, double solenoid valves & GasMultiBloc®
Dungs
DUNGS K01/1 - Closed Position Indicator switch for solenoid valves, double solenoid valves & GasMultiBloc®
DUNGS PBV - Push Button Shutoff Valve (US/CA)
Dungs
DUNGS PBV - Push Button Shutoff Valve (US/CA)
DUNGS VI - Visual Indicator (US/CA)
Dungs
DUNGS VI - Visual Indicator (US/CA)