Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

DUNGS PBV - Push Button Shutoff Valve (US/CA) - Accessory
DungsAccessory

DUNGS PBV - Push Button Shutoff Valve (US/CA)

Dungs Accessory.

SKU 3G-OTH-02866

Also listed as: PBVUSCA · PBV US CA

Brand
Dungs
Item
PBV - Push Button Shutoff Valve
Category
Accessory
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Datasheet Content

[{"filename":"pbv_manual_us_261406.pdf","text":"Push Button Valve (PBV)\n for Pressure Gauges USA CDN\n Installation Instructions\n\n\n\n Table of Contents\n Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . Page 1\n Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1\n Attention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1\n Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2\n Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 3\n Operation and Mounting PBV . . . . . . . . . . . . . . Page 4\n\n\n\n\n Approvals\n DVGW VP 308 “Gas Shutoff Valves for Pressure Gauges”\n CE 0085 AQ 0985 to EU directive EU/90/396/EWG\n\n\n\n\n Attention\n The installation and maintenance Check the ratings in the speci-\n of this product must be done fications to make sure that they\n under the supervision of an ex- are suitable for your application.\n perienced and trained specialist.\n Never perform work if gas pres- [V] [A]\n sure or power is applied, or in [Hz] [VA]\n the presence of an open flame.\n\n Please read the instruction be- On completion of work on the\n fore installing or operating. Keep Safety Push Button Valve, perform a\n\n\n\n\n MC • Karl Dungs, Inc. • Push Button Valve • Edition 2015.09 • P/N 261406\n the instruction in a safe place. You\n first leakage and function test.\n\n\n O.K.\n find the instruction also at www.\n dungs.com If these instructions\n are not heeded, the result may\n be personal injury or damage to\n property.\n This product is intended for\n IFGC installations covered by, but not\n CSA limited to, the following codes\n UL and standards: NFPA 86, CSD-1,\n ANSI NFPA 85, NFPA 37 or CSA B149.3.\n NFPA\n\n\n Explanation of symbols\n 1, 2, 3 ... = Action\t\t\n • = Instruction\n1…4\n\fSpecification\nPush Button Valve The push button valve (PBV) replaces a manual ball valve when mounting pressure gauges to\n the gas piping. When manually actuated by pushing a spring return button, the pressure on the\n gauge can be read. Once released, the PBV automatically closes, and the pressure on the gauge\n is automatically removed. The PBV increases the life of the pressure gauge and protects the gauge\n from pressure surges, and it is used as a means to verify gauge still properly works.\n\n Max. Operating Pressure Ambient Temperature\n MOP = 70 PSI (5 bar) °F -5 °F ... +145 °F\n +155\n (-20 °C … +60 °C)\n Fluid Temperature\n 0\n -32 -32 °F ... +155 °F\n [PSI] (-0 °C … +70 °C)\n\n Gases\n Dry, natural gas, propane, butane;\n other noncorrosive gases. A “dry”\n Gas\n gas has a dew point lower than\n +15 °F and its relative humidity is\n less than 60 %.\n\n\n\n\n MC • Karl Dungs, Inc. • Push Button Valve • Edition 2015.09 • P/N 261406\n\n\n\n\n 2…4\n\f Dimensions\n 1/4” NPT Version Rp 1/2” Version\n\n\n\n\n 2.71” 2.71”\n 1.97” 2.81”\n 50 mm 71.5 mm\n\n\n\n\n 2.13” 2.52”\n 54 mm 1/4” NPT 64 mm 1/2 Rp\n\n\n\n\n Description Connection Type Order No.\n Push Button Valve 1/4“ NPT 267055\n Push Button Valve Rp 1/2“ 266828\n (Includes 1 Metal Seal)\n Metal Seal 227125\n\n\n\n\n MC • Karl Dungs, Inc. • Push Button Valve • Edition 2015.09 • P/N 261406\n\n\n\n\n3…4\n\f Operation and Mounting PBV\n 1) Pressure Gauge\n 1 2) Push Button Valve\n 3) Push to read gauge pressure, and release to remove\n pressure from gauge\n…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dungs Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Dungs Accessory.

Frequently Asked Questions

What is the DUNGS PBV Push Button Shutoff Valve used for?

The DUNGS PBV Push Button Shutoff Valve is used to isolate pressure gauges on gas piping systems. When the spring-return button is pressed, gauge pressure can be read; releasing the button automatically closes the valve, protecting the gauge from pressure surges and extending its service life.

What are the specifications of the DUNGS PBV Push Button Shutoff Valve?

The DUNGS PBV has a maximum operating pressure of 70 PSI (5 bar). Ambient temperature range is -5 °F to +145 °F (-20 °C to +60 °C), and fluid temperature range is -32 °F to +155 °F (-0 °C to +70 °C). It is approved for dry natural gas, propane, butane, and other noncorrosive gases.

Where to buy the DUNGS PBV Push Button Shutoff Valve in Singapore?

3G Electric supplies the DUNGS PBV Push Button Shutoff Valve to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact our team for pricing and lead time on this Dungs accessory.

How to install the DUNGS PBV Push Button Shutoff Valve?

Installation must be performed by a trained specialist. Ensure gas pressure and power are off before work. After mounting, perform a leakage and function test. Refer to the Dungs installation instructions for detailed steps. The valve automatically closes when the button is released, protecting the gauge.

Used in

Common applications for Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners

Dungs Products

3G Electric supplies Dungs accessory. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

More from Dungs

View all Dungs parts
Dungs
Dungs
DUNGS SAV Limit Switch
Dungs
Dungs
DUNGS SAV Reed Contact
DUNGS SBO / CO - Gas Orifices (US/CA)
Dungs
DUNGS SBO / CO - Gas Orifices (US/CA)
DUNGS CPI 400 & Visual Indicator - Valve Position Indication & Valve Switch Visual Indicator (VI) (US/CA)
Dungs
DUNGS CPI 400 & Visual Indicator - Valve Position Indication & Valve Switch Visual Indicator (VI) (US/CA)
DUNGS VBS / VCW - Gas Venturi Meters (US/CA)
Dungs
DUNGS VBS / VCW - Gas Venturi Meters (US/CA)
DUNGS Ignition Transformers (US/CA)
Dungs
DUNGS Ignition Transformers (US/CA)
DUNGS K01/1 - Closed Position Indicator switch for solenoid valves, double solenoid valves & GasMultiBloc®
Dungs
DUNGS K01/1 - Closed Position Indicator switch for solenoid valves, double solenoid valves & GasMultiBloc®
DUNGS VI - Visual Indicator (US/CA)
Dungs
DUNGS VI - Visual Indicator (US/CA)