Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

FBR FGP 160/M TC SA - Burners & Combustion
FBRBurners & Combustion

FBR FGP 160/M TC SA

The FBR FGP 160/M TC is a two-stage light-oil diesel burner for industrial heating applications, delivering 435–1900 kW thermal output with progressive and modulating flame control. It processes 36.7–160 kg/h fuel…

SKU 3G-FBR-00091

Brand
FBR
Item
FGP 160/M TC SA
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

FBR
Weight
150 kg
stage
Progressive and modulating
fuel type
Light oil
nozzle mm
210
fan motor w
4
power kw max
1900
power kw min
435
flow kg h max
160
flow kg h min
36.7
ip protection
IP40
noisiness dba
84.4-85.4
pump motor kw
0.75
electrical supply
3
power supply info
3~400V,1/N~230V-50Hz
current absorption a
2
thermal power mcal h
374/765-1634
nominal electric power w
5
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M Burners for light-oil two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. Composed by: air blower at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the easy setting and maintenance. Complete of nozzle, flexible pipes and line filter. Complete of flange and gasket for installation on generator. Fig. FGP 130/M EVO FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING TECHNICAL DATA FGP 75/M - FGP 100/M EVO MODEL FGP 75/M FGP 100/M EVO Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [Mcal/h] 178/357-816 164.2/408-1020 Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [kW] 207/415-949 190/474-1186 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 17.5/35-80 16.1/40-100 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Environmental conditions operation / storage: -15...+40°C฀/฀-20...+70°C,฀rel. humidity max.฀80% Max. temperature combustion air [°C] 60 60 Nominal electric power [kW] 2.2 2.4 Fan motor [kW] 1.5 1.5 Pump motor [kW] 0.55 0.75 Nominal fan motor current absorption [A] 3.4 4.5 Nominal pump motor current absorption [A] 1.6 1.6 Nominal auxiliary absorption [A] 0.82 0.82 Power supply: 3~400V,1/N~230V-50Hz Electric protection degree: IP40 IP40 Noiseness min. - max. ** [dBA] 78-82.5 82-83.6 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING OPERATING RANGE DIAGRAM FGP 75/M [mbar] FGP 75/M [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. OPERATING RANGE DIAGRAM FGP 100/M EVO [mbar] [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING TECHNICAL DATA FGP 130/M EVO MODEL FGP 130/M EVO Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [Mcal/h] 289/612-1326 Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [kW] 336/712-1542 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 28.3/60-130 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Environmental conditions operation / storage: -15...+40°C฀/฀-20...+70°C,฀rel. humidity max.฀80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 3 Fan motor [kW] 2.2 Pump motor [kW] 0.75 Nominal fan motor current absorption [A] 4.35 Nominal pump motor current absorption [A] 1.6 Nominal auxiliary absorption [A] 0.82 Power supply: 3~400V,1/N~230V-50Hz Electric protection degree: IP40 Noiseness min. - max. ** [dBA] 78-82.5 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). OPERATING RANGE DIAGRAM FGP 130/M EVO [mbar] 17 15 13 11 9 7 5 3 1 -1 0 200 400 600 800 1000 1200 1400 1600 1800 2000 [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING TECHNICAL DATA FGP 160/M MODEL FGP 160/M Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [Mcal/h] 374/765-1634 Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [kW] 435/889-1900 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 36.7/75-160 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Environmental conditions operation / storage: -15...+40°C฀/฀-20...+70°C,฀rel. humidity max.฀80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 5 Fan motor [kW] 4 Pump motor [kW] 0.75 Nominal fan motor current absorption [A] 7.45 Nominal pump motor current absorption [A] 2 Nominal auxiliary absorption [A] 0.82 Power supply: 3~400V,1/N~230V-50Hz Electric protection degree: IP40 Noiseness min. - max. ** [dBA] 84.4-85.4 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). OPERATING RANGE DIAGRAM FGP 160/M [mbar] 17 15 13…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR FGP 160/M TC is a two-stage light-oil diesel burner for industrial heating applications, delivering 435–1900 kW thermal output with progressive and modulating flame control. It processes 36.7–160 kg/h fuel flow and operates at IP40 protection with 84.4–85.4 dB noise levels.

Frequently Asked Questions

What is the FBR FGP 160/M TC SA diesel burner used for?

The FBR FGP 160/M TC SA is a two-stage light-oil diesel burner designed for industrial heating applications such as boilers and furnaces. It delivers 435–1900 kW thermal output with progressive or modulating flame control, making it suitable for processes requiring precise heat modulation and high efficiency.

What are the specifications of the FBR FGP 160/M TC SA burner?

The FBR FGP 160/M TC SA burner has a thermal power range of 435–1900 kW, fuel flow of 36.7–160 kg/h, and operates on light oil. It features a 4 kW fan motor, 0.75 kW pump motor, IP40 protection, and noise levels of 84.4–85.4 dBA. Power supply is 3~400V or 1/N~230V-50Hz.

Where to buy the FBR FGP 160/M TC SA burner in Singapore?

You can source the FBR FGP 160/M TC SA burner through 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this industrial diesel burner for your heating system.

How to install and maintain the FBR FGP 160/M TC SA burner?

Installation should follow the manufacturer's manual and local regulations, ensuring proper flange and gasket sealing on the generator. Maintenance includes regular cleaning of the nozzle, fuel filter, and combustion head. FBR recommends periodic inspection of the fan and pump motors for optimal performance.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FGP 160/M TL SA
FBR
FGP 160/M TL SA
FGP 160/2 TC SI
FBR
FGP 160/2 TC SI
FGP 75/M TC SA
FBR
FGP 75/M TC SA
FGP 160/2 LX TC SI
FBR
FGP 160/2 LX TC SI
FGP 160/2 TL SI
FBR
FGP 160/2 TL SI
FGP 75/M TL SA
FBR
FGP 75/M TL SA

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL