Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

FBR FGP 50/M TL EVO SA - Burners & Combustion
FBRBurners & Combustion

FBR FGP 50/M TL EVO SA

The FBR FGP 50/M TL EVO is a two-stage progressive light-oil burner for industrial heating applications, delivering 124–630 kW thermal output with modulating and hi-low flame control. IP44-rated with 78–82.5 dBA…

SKU 3G-FBR-00068

Brand
FBR
Item
FGP 50/M TL EVO SA
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

FBR
Weight
150 kg
stage
Progressive and modulating
fuel type
Light oil
nozzle mm
250
fan motor w
0.55
power kw max
630
power kw min
124
flow kg h max
53
flow kg h min
10.5
ip protection
IP44
noisiness dba
78-82.5
pump motor kw
0.37
electrical supply
3
power supply info
3~400V,1/N~230V-50Hz
current absorption a
1.2
thermal power mcal h
107/204-542
nominal electric power w
1.1
max combustion air temp c
60

Datasheet Content

LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING BRUCIATORIDIGASOLIOBISTADIO PROGRESSIVI OMODULANTI FGP฀50/M฀EVO Light-oil฀burners฀two฀stages฀progressive฀or฀modulating฀operation฀(if฀equipped฀with฀addition฀of฀optional฀ modulation฀kit฀PID฀and฀probe;฀to฀guarantee฀an฀ideal฀proportionality฀of฀the฀power฀supplied฀to฀the฀thermal฀ load). Composed฀฀by:฀fan฀at฀high฀pressurisation฀at฀reverse฀blades฀and฀combustion฀head฀with฀adjustment฀at฀high฀ efficiency฀and฀฀high฀flame฀stability. Compact฀฀overall฀dimensions฀and฀disposition฀rationalized฀of฀the฀components฀with฀accessibility฀facilitated฀for฀ the฀operations฀of฀setting฀and฀maintenance. Complete฀฀of฀nozzle,฀flexible฀pipes฀and฀line฀filter. Complete฀฀of฀flange฀and฀gasket฀for฀installation฀on฀generator. Fig. 1 FGP฀50/M฀EVO FGP฀50/M฀EVO LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING TECHNICAL฀DATA฀FGP฀50/M฀EVO MODEL FGP฀50/M฀EVO Thermal฀power฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀* [Mcal/h] 107/204-542 Thermal฀power฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀* [kW] 124/237-630 LIGHT-OIL฀flow฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀* [kg/h] 10.5/20-53 Fuel: LIGHT-OIL฀1.5°E฀at฀20°C฀=฀6.2฀cSt฀=฀35฀sec฀Redwood฀N°1 Intermitted฀working฀operation฀(min.฀1฀stop฀every฀24฀hours)฀two฀stages฀progressive฀or฀modulating Environmental฀conditions฀operation฀/฀storage: -15...+40°C฀/฀-20...+70°C,฀rel.฀humidity฀max.฀80% Max.฀temperature฀combustion฀air [°C] 60 Nominal฀electric฀power [kW] 1.1 Fan฀motor [kW] 0.55 Pump฀motor [kW] 0.37 Nominal฀fan฀motor฀current฀absorption [A] 1.4 Nominal฀pump฀motor฀current฀absorption [A] 1.2 Nominal฀auxiliary฀absorption [A] 0.6 Power฀supply: 3~400V,1/N~230V-50Hz Electric฀protection฀degree: IP44 * Reference฀conditions:฀Environment฀temperature฀20°C฀-฀Barometric฀pressure฀1013฀mbars฀-฀Altitude฀0฀metre฀(sea฀level). OPERATING฀RANGE฀DIAGRAM฀FGP฀50/M฀EVO <mbar> 13 11 9 7 5 3 )*30(92 1 -1 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 <kW> Fig. 2 X฀=฀Thermal฀power฀Y฀=฀Pression฀in฀the฀combustion฀chamber The฀firing฀rates฀has฀been฀obtained฀based฀on฀test฀boilers฀in฀accordance฀with฀EN267฀standards฀and฀are฀indicative฀of฀matching฀the฀burner฀to฀the฀ boiler.฀For฀the฀correct฀operation฀of฀the฀burner,฀combustion฀chamber฀dimensions฀must฀be฀in฀accordance฀with฀current฀regulation.฀In฀case฀of฀non- compliance,฀contact฀the฀manufacturer. FGP฀50/M฀EVO LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING DIMENSIONS฀[MM] O A B F P D E TC - TL * C Fig. 3 Dimensions฀FGP฀50/M฀EVO MODEL A B C D E F O P FGP฀50/M฀EVO 329 274 746 150 416.5 100 207 200 C2:฀Overall฀dimension฀with฀the฀burner฀out฀in฀position฀of฀maintenance. * see฀"flame฀tube฀length" FGP฀50/M฀EVO LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING BOILER฀PLATE * Suggested฀dimension฀of฀connection฀between฀burner and฀generator. Fig. 4 Boiler฀plate MODEL M N min N max L฀min L฀* L฀max FGP฀50/M฀EVO mm M10 205 226 160 160 180 FLAME฀TUBE฀LENGTH Flame฀tube฀length฀must฀be฀selected฀based฀on฀the฀specifications฀supplied฀by฀boiler฀manufacturer฀and,฀in฀any฀case,฀it must฀be฀greater฀than฀the฀thickness฀of฀the฀boiler฀door฀included฀its฀insulation. In฀case฀of฀boilers฀with฀flame฀inversion฀or฀front฀flue฀combustion฀chambers,฀it฀is฀necessary฀to฀insulate฀the฀area฀between the฀flame฀tube฀and฀front฀door฀with฀refractory฀material.฀This฀protection฀material฀must฀not฀impede฀flame฀tube฀ extraction. MODEL TC TL ** FGP฀50/M฀EVO mm 250 335 **฀For฀different฀flame฀lengths,฀please฀contact฀our฀Technical-Sales฀Department. FGP฀50/M฀EVO LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING BURNER฀SIGNAL฀DESCRIPTION In฀the฀picture฀below฀there฀are฀indicated฀all฀the฀signalation฀present฀on฀the฀burner: 2 1 Fig. 5 Burner฀signal฀description฀ LEGEND 1) ON/OFF฀button 2) Reset฀from฀lockout฀button฀+฀status฀lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). FGP฀50/M฀EVO LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING PRODUCT฀SPECIFICATION SHORT฀DESCRIPTION Light-oil฀burners฀two฀stages฀progressive฀(hi-low฀flame)฀or฀modulating฀(PID฀fully฀modulating)฀if฀equipped฀with฀ addition฀of฀optional฀modulation฀kit฀and฀probe. DETAILED฀SPECIFICATION Light-oil฀burner฀two฀stages฀progressive฀(hi-low฀flame)฀or฀modulating฀(PID฀fully฀modulating)฀if฀equipped฀with฀addition฀ of฀optional฀modulation฀kit฀and฀probe;฀composed฀by: • Fan฀at฀high฀pressurisation฀at฀reverse฀blades; • Combustion฀head฀with฀adjustment฀at฀high฀performance฀and฀elevated฀flame฀stability; • Flange฀and฀insulating฀gasket฀for฀fixing฀at฀boiler; • Three-phase฀power฀supply; • Photodiode฀for฀flame฀detection; • IP฀44฀electric฀protection฀level; • Servomotor฀for฀air฀shutter฀and฀for฀the฀pressure฀regulator; • Easy฀extraction฀of฀combustion฀head฀without฀get฀off฀the฀burners฀by฀bolier; • Maximum฀light-oil฀pressure฀switch฀to฀stop฀the฀burner฀in฀case฀of฀the฀light-oil฀pressure฀on฀the฀return฀is฀higher฀then฀the฀set฀point value; • Safety฀air฀pressure฀switch฀to฀stop฀the฀burner฀in฀lock-out฀(by฀stopping฀the฀pump฀motor)฀in฀case฀of฀failed฀or฀anomalous฀fan operation; • Dedicated฀motor฀for฀the฀activation฀of฀the฀light-oil฀pump; • Set฀up฀for฀the฀additional฀specific฀kit฀that฀transforms฀burner฀operation฀as฀modulating฀i.e.฀the฀modulating฀kit฀allows฀to฀supply any฀power฀between฀the฀minimun฀and฀the฀maximum฀value฀based฀on฀instantaneous฀loading฀request. CONFORMING฀TO: • CE฀rules; • 2014/30/UE฀Directive฀E.M.C.; • 2014/35/UE฀Directive฀L.V.; • 2006/42/CE฀-฀2006/42/EG฀-฀2006/42/EC฀Directive฀M.D.; • Directive฀PED฀ 2014/68/UE฀ (ART.4,PAR.3); • Reference฀rules:฀EN267฀(liquid฀fuel)฀-฀EN746-2฀(industrial฀thermoprocessing฀equipment). STANDARD฀EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Power฀modulating฀kits฀for฀temperatures; • Power฀modulating฀kits฀for฀pressures; • Temperature฀probe฀0°C-400°C฀(PT฀100฀a฀0°฀C); • Temperature฀probe฀0°C-350°C฀(J฀probe); • Temperature฀probe฀0°C-1200°C฀(K฀probe); • Pressure฀probe฀0-3฀bar,฀0-6฀bar.฀0-16฀bar,฀0-20฀bar,฀0-30฀bar; • Noise฀protection. The฀illustrations฀and฀data฀here฀shown฀are฀indicative.฀F.B.R.฀Bruciatori฀S.r.l.฀reserves฀the฀right฀to฀bring,฀without฀any฀obligation฀of฀warning,฀any฀changes฀that฀would฀be฀appropriate฀to฀the฀continuing฀development฀of฀their฀products. FGP฀50/M฀EVO
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR FGP 50/M TL EVO is a two-stage progressive light-oil burner for industrial heating applications, delivering 124–630 kW thermal output with modulating and hi-low flame control. IP44-rated with 78–82.5 dBA noise levels, it integrates dual motors and operates on 3~400V, 1/N~230V-50Hz power for demanding combustion systems.

Frequently Asked Questions

What is the FBR FGP 50/M TL EVO SA diesel burner used for?

The FBR FGP 50/M TL EVO SA is a two-stage progressive light-oil burner designed for industrial heating applications such as boilers, furnaces, and thermal fluid heaters. It delivers 124–630 kW thermal output with modulating or hi-low flame control, making it suitable for demanding combustion systems in manufacturing and process industries.

What are the specifications of the FBR FGP 50/M TL EVO SA burner?

The FBR FGP 50/M TL EVO SA burner has a thermal power range of 124–630 kW, light-oil flow of 10.5–53 kg/h, and operates on 3~400V, 1/N~230V-50Hz power supply. It features IP44 protection, dual motors (fan 0.55 kW, pump 0.37 kW), and noise levels of 78–82.5 dBA. The burner supports progressive two-stage or modulating operation with an optional PID kit.

Where to buy the FBR FGP 50/M TL EVO SA burner in Singapore?

3G Electric supplies the FBR FGP 50/M TL EVO SA burner to Singapore. We handle sourcing, logistics, customs clearance, and delivery to your site. Contact our team for pricing and lead time. We provide technical support for installation and commissioning across Singapore's industrial sector.

How to install and maintain the FBR FGP 50/M TL EVO SA burner?

Install the FBR FGP 50/M TL EVO SA burner using the supplied flange and gasket, ensuring the combustion chamber dimensions comply with EN267 standards. For maintenance, regularly clean the nozzle, flexible pipes, and line filter. Access to setting and maintenance components is facilitated by the burner's compact, rationalised design. Always follow the manufacturer's manual.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FGP 50/M TC EVO SA
FBR
FGP 50/M TC EVO SA
FGP 100/M TL EVO SA
FBR
FGP 100/M TL EVO SA
FGP 130/M TL EVO SA
FBR
FGP 130/M TL EVO SA
FGP 130/M TC EVO SA
FBR
FGP 130/M TC EVO SA
FGP 100/M TC EVO SA
FBR
FGP 100/M TC EVO SA
FGP 50/2 TL EVO 3 SI
FBR
FGP 50/2 TL EVO 3 SI

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL