FBR G X5/2 TC SI
FBR G X5/2 TC SI is a two-stage light-oil burner delivering 101–400 kW thermal output, ideal for industrial heating applications. Features a 215 mm nozzle, 33.7 kg/h maximum fuel flow, and 71–72 dBA noise level…
SKU 3G-FBR-00046
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
FBR G X5/2 TC SI is a two-stage light-oil burner delivering 101–400 kW thermal output, ideal for industrial heating applications. Features a 215 mm nozzle, 33.7 kg/h maximum fuel flow, and 71–72 dBA noise level. Suits medium to large commercial and industrial installations.
Frequently Asked Questions
What is the FBR G X5/2 TC SI used for?
The FBR G X5/2 TC SI is a two-stage light-oil burner designed for industrial heating applications. It delivers 101–400 kW thermal output, making it suitable for medium to large commercial and industrial installations such as boilers and furnaces. Its high efficiency and flame stability ensure reliable performance in demanding environments.
What are the specifications of the FBR G X5/2 TC SI?
The FBR G X5/2 TC SI is a two-stage light-oil burner with a 215 mm nozzle, 33.7 kg/h maximum fuel flow, and 71–72 dBA noise level. It has a 450 W fan motor, 600 W nominal electric power, 2.7 A current absorption, IP 40 protection, and operates on 1N~230V 50Hz. Maximum combustion air temperature is 60 °C.
Where to buy the FBR G X5/2 TC SI in Singapore?
You can source the FBR G X5/2 TC SI through 3G Electric, an established industrial equipment distributor since 1990. We handle logistics, customs clearance, and delivery to Singapore, ensuring the burner reaches your facility. Contact our team for pricing and lead time on this FBR model.
How to install the FBR G X5/2 TC SI burner?
Install the FBR G X5/2 TC SI by mounting the flange and gasket on the boiler, connecting the 7-pole connector, flexible pipes, and line filter. Adjust the combustion head micro adjustment for optimal flame stability. Ensure environmental conditions stay within -15 to +40 °C and follow EN267 standards for combustion chamber dimensions.
Used in
Common applications for FBRFBR Products