Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Fireye MicroM Amplifier Modules. The Fireye MEUV1, MEUV4, MEUVS1, MEUVS4, MERT1 - Programmer & Amplifier Modules
FireyeProgrammer & Amplifier Modules

Fireye MicroM Amplifier Modules. The Fireye MEUV1, MEUV4, MEUVS1, MEUVS4, MERT1

The Fireye 3G-OTH-02818 Amplifier Modules are programmer and amplifier modules. Available models include MEUV1, MEUV4, MEUVS1, MEUVS4, MERT1, MERT4, MEIR1, MEIR4, MECD1, and MECD4. These modules are cULus and FM…

SKU 3G-OTH-02818

Brand
Fireye
Item
MicroM Amplifier Modules. The Fireye MEUV1, MEUV4, MEUVS1, MEUVS4, MERT1
Category
Programmer & Amplifier Modules
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Fireye
Models
MEUV1, MEUV4, MEUVS1, MEUVS4, MERT1, MERT4, MEIR1, MEIR4, MECD1, MECD4
Category
Programmer & Amplifier Modules
Approvals
cULus, FM Approved

Datasheet Content

[{"filename":"MAMP-1_MicroM_Amplifier_Modules_MEUV1_MEUV4_MEUVS1_MEUVS4_MEIR1_MEIR4_MERT1_MERT4_MECD1_MECD4_English_2013-04-03.pdf","text":"\n\n\n MAMP-1\n APRIL 3, 2013\n\n\n\n MEUV1, MEUV4,MEUVS1,\n MEUVS4, MEIR1, MEIR4,\n MERT1, MERT4,\n MECD1 and MECD4\n AMPLIFIER MODULES FOR USE WITH THE\n FIREYE® MODULAR 3G-OTH-02818™ CONTROL\n\n\n\n\n APPROVED\n\n\n\n\nDESCRIPTION\n The Fireye MEUV1, MEUV4, MEUVS1, MEUVS4, MERT1, MERT4, MEIR1, MEIR4, MECD1\n and MECD4 are Amplifier Modules used with the Fireye Modular 3G-OTH-02818 control. These amplifier\n modules provide flame scanning capabilities using any of the Fireye standard ultraviolet scanners,\n self-check scanners, infrared scanners, cadmium sulfide scanners and flame rods. The Flame Failure\n Response Time (FFRT) of the control is determined by the selection of the amplifier module (see\n Ordering Information). Test jacks are provided on the amplifier modules to permit flame signal mea-\n surement during operation and is a uniform 0-10 vdc for all models.\n After scanner selection, the proper amplifier module must be used in the Modular 3G-OTH-02818 chassis\n (see Ordering Information). The amplifier module incorporates a plug-in design for ease of installa-\n tion.\n The programmer module determines the operational characteristics of the control (e.g. relight, purge\n timing, etc.).\n For proper and safe application of this product, you must refer to bulletin MC-5000 for a detailed\n description of the operation of the Modular 3G-OTH-02818 control, including installation instructions,\n operating sequences for the programmer modules, etc. Also follow the scanner installation and wir-\n ing instructions found in bulletins MC-5000 for proper flame scanning operation.\n\n\n\n\n WARNING: Selection of this control for a particular application should be made by a com-\n petent professional, licensed by a state or other government agency. Inappropriate application\n of this product could result in an unsafe condition hazardous to life and property. Installation\n should not be considered complete until pilot turndown and other appropriate performance\n tests have been successfully completed.\n\n\n\n\n 1\n\f \n\n\n\n\nORDERING INFORMATION\nFlame Amplifier Selection:\n\n 3G-OTH-02818 Amplifier Models:\n MEUV1 UV amplifier,0.8 second FFRT, uses UV1A, UV2, UV8A and 45UV3-1050 scanners.\n MEUV4 UV amplifier, 4 second (max) FFRT, uses UV1A, UV2, UV8A and 45UV3-1050 scanners.\n MEUVS1 UV Self-Check amplifier,0.8 second FFRT, uses 45UV5-1009 scanner.\n MEUVS4 UV Self-Check amplifier, 4 second (max) FFRT, uses 45UV5-1009 scanner.\n MERT1 Flame Rod / Photocell amplifier,0.8 second FFRT, uses 69ND1 or 45CM1 (obsolete).\n MERT4 Flame Rod / Photocell amplifier, 4 second (max) FFRT, uses 69ND1 or 45CM1 (obsolete).\n MEIR1 Infrared amplifier0,.8 second FFRT, uses 48PT2 scanner.\n MEIR4 Infrared amplifier, 4 second (max) FFRT, uses 48PT2 scanner.\n MECD1 Cadmium sulfide amplifier,0.8 second FFRT, uses CS1A5 scanner.\n MECD4 Cadmium sulfide amplifier, 4 second (max) FFRT, uses CS1A5 scanner.\n\n\nFLAME SCANNERS\n\n\n\n\n CAUTION: The UV1, UV2, UV8A, UV90 and 45UV3 ultra-violet flame scanners and associated\n amplifier modules are non self-checking UV systems and should be applied only to burners that\n cycle often (e.g.: a minimum of once per 12 hours) in order for the safety checking circuit to be\n exercised. If component checking is required during burner operation for constantly fired burners,\n utilize the self-checking ultra-violet flame scanners (45UV5) with associated amplifier module\n (MEUVS1, MEUVS4) or the infrared flame scanner (48PT2) with associated Auto Check amplifier\n (MEIR1, MEIR4).\n\n UV SCANNERS: BULLETIN\n UV1A3 1/2” NPT connector, 3 ft. (914mm) TC-ER cable, non self-checking. SC-102\n UV1A6 1/2” NPT connector, 6 ft. (1828mm) TC-ER cable, non self-checking. SC-102\n UV2 3/8” NPT connector, 3 ft. (914mm) TC-ER cable, non self-checking. SC-102\n UV8A 1/2” NPT 90° head, 6 ft. unshielded leads. SC-102\n 45UV3-1050 3/4” sleeve/set screw mount. Non self-checking. SC-102\n 45UV5-1009 UV self-check scanner 8 ft. (2400mm) leads. 1” NPT threads. SC-101\n 120 VAC shutter. Use with MEUVS type amplifier.\n UV90-3 UV, 90° lateral view, 3 ft. (914mm) flex conduit SC-102\n UV90-6 UV, 90° lateral view, 6 ft. (1828mm) flex conduit SC-102\n UV90-9 UV, 90° lateral view, 9 ft. (2742mm) flex conduit SC-102\n\n FLAME DETECTORS: BULLETIN\n 45CM1-1000 Photocell with filter. OBSOLETE\n 45CM1-1000Y Photocell without filter. OBSOLETE\n 69ND1-1000K4 12 inch flame rod, 1/2” NPT connector. SC-103\n 69ND1-1000K6 18 inch flame rod, 1/2” NPT connector. SC-103\n 69ND1-1000K8 24 Inch flame rod, 1/2” NPT connector. SC-103\n\n\n2\n\f \n\n\n\n\n INFRARED SCANNERS: BULLETIN\n 48PT2-1003 Infrared scanner 8 ft. (2400mm) TC-ER cable, straight head. SC-103\n 48PT2-1007 Infrared scanner 4 ft. (1200mm) TC-ER cable, straight head. SC-103\n 48PT2-9003 Infrared scanner 8 ft. (2400mm) TC-ER cable, 90° head. SC-103\n 48PT2-9007 Infrared scanner 4 ft. (1200mm) TC-ER cable, 90° head. SC-103\n 48PT2-9007W Infrared scanner 4 ft. (1200mm) shielded cable, 90° head, water SC-103\n repellent. OBSOLETE, Replaced by 48PT2-9007\n\n CADMIUM SULPHIDE:\n CS1A5 Cadmium sulfide 5’, with mounting bracket\n\nParts and Accessories\n Part Number Description\n 4-263-1 Firetron cell for 48PT2 only.\n 4-314-1 UV tube for 45UV5-1005-1009, 45UV2, 45UV3.\n 10-88 Set of 3 orifice plugs (1/16'', 1/8'', 3/16'') for 48PT1, 48PT2.\n 19-30 Pyrex window for 60-801 union.\n 35-69 Heat insulator, 1/2\" connection for 48PT, UV1A.\n 35-75 Water cooled adapter for 48PT, UV1A.\n 35-127-1 Heat insulator. 1\" NPT for 45UV5.\n 46-38 Replacement lens (1.25\" dia.) for 45UV5,.\n 46-56 Quartz magnifying lens for 45UV3, (1\" dia.).\n 46-58 Quartz (1”dia.) lens for 60-1290 union.\n 60-302 Swivel mtg. adapter, 1/2\" NPT for 48PT1, 48PT2, UV1A.\n 1/ \" union with Pyrex window for 48PT1, 48PT2.\n 60-801 2\n 60-1199-1 Coupling with quartz window, 1\" NPT for 45UV2, 45UV3, 45UV5.\n 60-1199-2 Coupling with quartz window, 1\" BSP for 45UV2, 45UV3, 45UV5.\n 60-1257 Union with quartz window, 1/2\" NPT for UV1A.\n 60-1290 Union with quartz lens, 1/2\" NPT for UV1A.\n 60-1664-3 Swivel mount adapter, 1\" NPT for 45UV5 scanners.\n 61-436 Lens cap (standard) for 48PT scanners.\n 61-2914 Shutter and bracket assembly only for 45UV5-1009.\n 61-3263 Shutter, bracket and lens assembly with lens holder and gasket for 45UV5-1005-1009,\n 1105 (includes a 61-2914).\n 82-95 Lens holder for 45UV5 scanner.\n 92-45 Quartz window used in 45UV3-1050 and 60-1237 union.\n 92-48 Quartz window used in 60-1199 union.\n 124-13 “O” Ring used in 60-1199 union.\n 124-14 “O” Ring used in 60-801, 60-1257, 60-1290.\n\n\n\nRemove power from the control and remove the control from its wiring base before\nproceeding.\n\n\n\n\n 3\n\f \n\n\n\n\nINSTALLATION\n The amplifier modules are used with the Fireye\n Modular 3G-OTH-02818 Base Chassis (P/N MEC120,\n MEC120C, MEC120R, MEC120D, MEC120RC\n for 120VAC, P/N MEC230, for 230VAC). They\n are installed in the chassis by grabbing hold of the\n amplifier module by the edges of its printed cir-\n cuit board, aligning the module with the guide\n slots on the opening in the middle of the chassis,\n and inserting the module into the pin connectors.\n The amplifier modules are designed to fit in the\n proper slot only. DO NOT FORCE THEM.\n\n\n\n 12\n\n 11\n\n 10\n\n\n 9\n\n\n\n\n AMPLIFIER TEST JACK VOLTAGE\n 8\n\n 7\n\n\n 6\n CORRELATION BETWEEN\n 5…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fireye Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Fireye 3G-OTH-02818 Amplifier Modules are programmer and amplifier modules. Available models include MEUV1, MEUV4, MEUVS1, MEUVS4, MERT1, MERT4, MEIR1, MEIR4, MECD1, and MECD4. These modules are cULus and FM Approved.

Frequently Asked Questions

What are Fireye 3G-OTH-02818 Amplifier Modules used for?

Fireye 3G-OTH-02818 Amplifier Modules are used with the Fireye Modular 3G-OTH-02818 control system to provide flame scanning capabilities. They work with Fireye ultraviolet, self-check, infrared, cadmium sulfide scanners, and flame rods to detect burner flame presence and ensure safe boiler or industrial furnace operation.

What are the specifications of Fireye 3G-OTH-02818 Amplifier Modules?

Fireye 3G-OTH-02818 Amplifier Modules include models MEUV1, MEUV4, MEUVS1, MEUVS4, MERT1, MERT4, MEIR1, MEIR4, MECD1, and MECD4. They feature a plug-in design, a uniform 0-10 VDC flame signal test jack, and Flame Failure Response Times of 0.8 or 4 seconds. Approvals include cULus and FM.

Where to buy Fireye 3G-OTH-02818 Amplifier Modules in Singapore?

You can source Fireye 3G-OTH-02818 Amplifier Modules from 3G Electric in Singapore. We supply genuine Fireye components and handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on your required model.

How to select the right Fireye 3G-OTH-02818 Amplifier Module?

Select the Fireye 3G-OTH-02818 Amplifier Module based on your scanner type and required Flame Failure Response Time. For example, use MEUV1 (0.8 second FFRT) with UV1A scanners, or MEUVS4 (4 second FFRT) with 45UV5-1009 self-check scanners. Always consult bulletin MC-5000 for proper application and installation guidance.

Used in

Common applications for Fireye
Power-plant auxiliary boiler — M-Series II controller with UV flame scanner, programmed for gas/oil switchover and flame-presence monitoring.
Refinery process heater — MP100E programmer module managing multi-stage ignition and flame-out shutdown interlocks on high-pressure burners.
Petrochemical facility thermal oxidizer — MAUV1T UV amplifier module processing scanner signal from high-temperature burner housings with immune-response filtering.
Large-scale industrial oven (metal treating) — M-Series II with remote reset capability and dual-fuel solenoid isolation for operator safety and burner protection.
Cogeneration plant fuel-gas burner — Fireye scanner and modular controller stack integrated into BMS with remote monitoring of flame status and controller fault codes.

Fireye Products

3G Electric supplies Fireye programmer & amplifier modules. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Flame sensor amplifier module for industrial burner management systems. Detects and amplifies flame signals from ultraviolet or infrared scanners to ensure safe burner operation in boilers, furnaces, and process heaters. Replacement part for flame safeguard systems in HVACR and combustion applications
Fireye
Flame sensor amplifier module for industrial burner management systems. Detects and amplifies flame signals from ultraviolet or infrared scanners to ensure safe burner operation in boilers, furnaces, and process heaters. Replacement part for flame safeguard systems in HVACR and combustion applications
Flame sensor amplifier module for use with Fireye flame scanners in burner management systems. Amplifies flame signals from ultraviolet or infrared scanners to ensure safe burner operation. Suitable for industrial boilers, furnaces, and process heaters
Fireye
Flame sensor amplifier module for use with Fireye flame scanners in burner management systems. Amplifies flame signals from ultraviolet or infrared scanners to ensure safe burner operation. Suitable for industrial boilers, furnaces, and process heaters
Amplifier module for use in flame safeguard control systems. Processes signals from flame detectors to manage burner operation in commercial and industrial heating applications such as boilers and furnaces
Fireye
Amplifier module for use in flame safeguard control systems. Processes signals from flame detectors to manage burner operation in commercial and industrial heating applications such as boilers and furnaces
Flame sensor amplifier module for burner management systems. Interprets flame signals from a scanner to confirm burner ignition and flame presence. Used in boilers, furnaces, and process heaters for safe combustion control
Fireye
Flame sensor amplifier module for burner management systems. Interprets flame signals from a scanner to confirm burner ignition and flame presence. Used in boilers, furnaces, and process heaters for safe combustion control
Flame sensor amplifier module for use in burner management systems. Processes and amplifies flame signals from a scanner to support flame safeguard control in commercial and industrial heating applications such as boilers, furnaces, and process heaters
Fireye
Flame sensor amplifier module for use in burner management systems. Processes and amplifies flame signals from a scanner to support flame safeguard control in commercial and industrial heating applications such as boilers, furnaces, and process heaters
The Fireye MERT4 is a flame sensor amplifier module used in combustion safety systems. It processes signals from a flame scanner to confirm burner flame presence, supporting safe operation in boilers, furnaces, and process heaters
Fireye
The Fireye MERT4 is a flame sensor amplifier module used in combustion safety systems. It processes signals from a flame scanner to confirm burner flame presence, supporting safe operation in boilers, furnaces, and process heaters

More from Fireye

View all Fireye parts
M-Series II Amplifier Modules. The Fireye MART1, MART3, MART1T, MAUV1, MAUV3, and MAUV1T are advanced Amplifier Modules designed for use with the Fireye Modular M-SERIES II Control. These versatile amplifier modules are essential for flame scanning, offering compatibility with Fireye’s standard ultraviolet (UV) scanners and flame rods to ensure accurate flame detection and system performance
Fireye
M-Series II Amplifier Modules. The Fireye MART1, MART3, MART1T, MAUV1, MAUV3, and MAUV1T are advanced Amplifier Modules designed for use with the Fireye Modular M-SERIES II Control. These versatile amplifier modules are essential for flame scanning, offering compatibility with Fireye’s standard ultraviolet (UV) scanners and flame rods to ensure accurate flame detection and system performance
Flame-Monitor Amplifier Modules. The Fireye E1R1, EUV1, ERT1, and EUVS4 Amplifier Modules are essential components of the Fireye Flame-Monitor System, designed to enhance flame scanning and monitoring. These modules are compatible with various Fireye flame scanning devices, including AutoCheck infrared scanners, standard ultraviolet scanners, flame rods, and ultraviolet self-check scanners. Each module must be selected based on the type of scanner used and inserted into the appropriate Flame-Monitor chassis for optimal performance
Fireye
Flame-Monitor Amplifier Modules. The Fireye E1R1, EUV1, ERT1, and EUVS4 Amplifier Modules are essential components of the Fireye Flame-Monitor System, designed to enhance flame scanning and monitoring. These modules are compatible with various Fireye flame scanning devices, including AutoCheck infrared scanners, standard ultraviolet scanners, flame rods, and ultraviolet self-check scanners. Each module must be selected based on the type of scanner used and inserted into the appropriate Flame-Monitor chassis for optimal performance
MicroM Programmer Modules. The Fireye MicroM Series is a compact, microprocessor-based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial heating and process equipment, regardless of fuel type. The system offers significant advantages, including the elimination of discrete components traditionally used for timing functions, providing a more reliable and efficient solution for industrial applications
Fireye
MicroM Programmer Modules. The Fireye MicroM Series is a compact, microprocessor-based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial heating and process equipment, regardless of fuel type. The system offers significant advantages, including the elimination of discrete components traditionally used for timing functions, providing a more reliable and efficient solution for industrial applications
Flame-Monitor EP Programmer Modules. The Fireye programmer modules—including EP100S, EP200S, EP300S (extended purge), EP160, EP161 (extended MTFI), EP163 (programmable), EP170, EP174 (early spark termination), EP165, EP166 (pilot stabilization), EP177 (early spark termination and programmable operating parameters), EP260, EP265 (pilot stabilization), EP270 (early spark termination), EP380, EP381, EP382, EP383, and EP390—are designed for use with the Flame-Monitor Burner Management Control System
Fireye
Flame-Monitor EP Programmer Modules. The Fireye programmer modules—including EP100S, EP200S, EP300S (extended purge), EP160, EP161 (extended MTFI), EP163 (programmable), EP170, EP174 (early spark termination), EP165, EP166 (pilot stabilization), EP177 (early spark termination and programmable operating parameters), EP260, EP265 (pilot stabilization), EP270 (early spark termination), EP380, EP381, EP382, EP383, and EP390—are designed for use with the Flame-Monitor Burner Management Control System