Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

FBR K 550/M TL EL EVO is a dual-fuel diesel burner for gas and light-oil applications, delivering 698–6395 kW across two modulating stages. Operating at 3~400V with 84–85 dBA noise output, it provides thermal power…

SKU 3G-FBR-00232

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

FBR
Weight
274 kg
stage
2 stages sliding or modulating
fuel type
Dual fuel gas/light oil
nozzle mm
560
fan motor w
9
power kw max
6395
power kw min
698
ip protection
IP40
noisiness dba
84-85
pump motor kw
2.2
gas consumption
47/140-409
electrical supply
3
power supply info
3~400V,
current absorption a
23.5
thermal power mcal h
400/1200-3500
nominal electric power w
12.5
max combustion air temp c
60

Datasheet Content

DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073571_A_gb OR MODULATING WITH ELECTRONIC CONTROL BOX K 350/M-EL EVO - K 450/M-EL EVO - K 550/M-EL EVO Dual fuel burners gas/light oil with electronic control box. Two stages progressive or modulating operation (if equipped with addition of optional modulation kit PID and probe; to guarantee an ideal proportionality of the power supplied to the thermal load). Composed by: fan at high pressurisation at reverse blades and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled and tested; composed by: working valve class A - safety valve class A - minimum gaspressure switch - gas valve proving pressure switch - filter Supplied with nozzle, fuel selection switch, flange and gasket for installation on boiler, flexible hoses, line filter. The servomotors are indipendent and managed directly from the electronic control box of the burner: one servomotor for the gas modulator, one servomotor for the air shutter and one servomotor fo the light-oil modulator. The burners are equipped with a display that allows to: - adjust the operating parameters of the burner - visualize the flame intensity - adjust the operating curve of the burner (air / fuel ratio) With the addition of optional accessories (probes) thanks to the most advanced systems for automatic modulation in mechanical or electronic version, the burner constantly ensures the proper gas / air ratio. The maximum efficiency of the returns in each combustion point derived from the punctual adaptation of the thermal load to the heat requirements of the burner at any instant of operation. In the version with the electronic cam the fuel / combustion air curve, more extended, is fully exploited, guaranteeing excellent performance in terms of accuracy and speed, even during the calibration phase. A microprocessor monitors the different stages of the process and allows the correct repetition of the sequences of operation. Optional accessories: PID power modulator kit, probe, PC interface, VSD, O2 control, O2 + CO control, field bus (profibus, modbus, profinet), Touchscreen HMI panel. K 350/M-EL EVO - K 450/M-EL EVO - K 550/M-EL EVO DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073571_A_gb OR MODULATING WITH ELECTRONIC CONTROL BOX CONTROL BOX LAMTEC BT3 Fig. Control box Lamtec BT3 K 350/M-EL EVO - K 450/M-EL EVO - K 550/M-EL EVO DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073571_A_gb OR MODULATING WITH ELECTRONIC CONTROL BOX TECHNICAL DATA MODEL K 350/M-EL EVO K 450/M-EL EVO K 550/M-EL EVO Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 400/1202-3508 438/1600-4500 426/2000-5500 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 465/1395-4070 510/1860-5232 496/2325-6395 Gas flow G20 (NAT. GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 49/132-408 52/187-526 50/234-643 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 20/53-163 20/72-203 20/90-248 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL, I2E(R)B/I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stage progressive or modulating Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 60 Min. pressure gas train D2" FS50 NAT.GAS/L.P.G. ** [mbar] 200/79 324/128 -/226 Min. pressure gas train DN65 FS65 NAT. GAS/L.P.G. ** [mbar] 66/27 103/43 325/134 Min. pressure gas train DN80 FS80 NAT. GAS/L.P.G. ** [mbar] 53/23 82/35 223/90 Min. pressure gas train DN100 FS100 NAT. GAS/L.P.G. ** [mbar] 42/19 65/28 124/52 Max. pressure at the entry of valves (Pe. max) [mbar] 360-500 360-500 360-500 LIGHT-OIL flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 42/114-351 44/160-450 43/200-550 Fuel: light-oil 1.5°E at 20°C = 6.2 cSt = 35sec Redwood N°1 Nominal electric power [kW] 12 14 18 Fan motor [kW] 9.2 11 15 Pump motor [kW] 2.2 2.2 2.2 Nominal fan motor current absorption [A] 18.8 22 30 Nominal pump motor current absorption [A] 4.7 4.7 4.7 Nominal absorption auxiliary [A] 0.5 0.5 0.5 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP40 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). K 350/M-EL EVO - K 450/M-EL EVO - K 550/M-EL EVO DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073571_A_gb OR MODULATING WITH ELECTRONIC CONTROL BOX OPERATING RANGE DIAGRAM [ mbar] 25 K 350/M-EL EVO 20 15 10 5 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 [kW] Fig. X = Thermal power Y = pressure in combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. [ mbar] 25 K 450/M-EL EVO 20 15 10 5 0 200 1200 2200 3200 4200 5200 6200 [kW] Fig. X = Thermal power Y = pressure in combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. K 350/M-EL EVO - K 450/M-EL EVO - K 550/M-EL EVO DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073571_A_gb OR MODULATING WITH ELECTRONIC CONTROL BOX 25 [ mbar] K 550/M-EL EVO 20 15 10 5 0 0 1000 2000 3000 4000 5000 6000 7000 [kW] Fig. X = Thermal power Y = pressure in combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. K 350/M-EL EVO - K 450/M-EL EVO - K 550/M-EL EVO DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073571_A_gb OR MODULATING WITH ELECTRONIC CONTROL BOX DIMENSIONS [MM] Fig. Dimensions MODEL A B C D E F G H R1 R2 R3 R4 K 350/M-EL EVO - D2" 490 600 550 380 160 1170 650 275 320 720 855 890 K 350/M-EL EVO - DN65 490 600 550 380 160 1170 650 275 320 745 890 780 K 350/M-EL EVO - DN80 490 600 550 380 160 1170 650 275 320 745 915 800 K 350/M-EL EVO - DN100 490 600 550 380 160 1170 650 275 320 795 975 840 K 450/M-EL EVO - D2" 490 600 550 380 160 1170 650 275 320 720 855 890 K 450/M-EL EVO - DN65 490 600 550 380 160 1170 650 275 320 745 890 780 K 450/M-EL EVO - DN80 490 600 550 380 160 1170 650 275 320 745 915 800 K 450/M-EL EVO - DN100 490 600 550 380 160 1170 650 275 320 795 975 840 K 550/M-EL EVO - D2" 490 600 550 380 160 1170 650 275 320 720 855 890 K 550/M-EL EVO - DN65 490 600 550 380 160 1170 650 275 320 745…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR K 550/M TL EL EVO is a dual-fuel diesel burner for gas and light-oil applications, delivering 698–6395 kW across two modulating stages. Operating at 3~400V with 84–85 dBA noise output, it provides thermal power of 400–3500 kcal/h and suits industrial heating and power-generation installations.

Frequently Asked Questions

What is the FBR K 550/M TL EL EVO used for?

The FBR K 550/M TL EL EVO is a dual-fuel diesel burner designed for industrial heating and power-generation installations. It operates on gas or light oil, delivering 698–6395 kW across two modulating stages, making it suitable for boilers, thermal fluid heaters, and process heat applications in Singapore's manufacturing and energy sectors.

What are the specifications of the FBR K 550/M TL EL EVO?

The FBR K 550/M TL EL EVO burner has a power range of 698–6395 kW, operates on 3~400V electrical supply with 23.5 A current absorption, and produces 84–85 dBA noise. It weighs 274 kg, features a 560 mm nozzle, IP40 protection, and includes a 9 kW fan motor and 2.2 kW pump motor. Thermal output is 400–3500 kcal/h.

Where to buy the FBR K 550/M TL EL EVO in Singapore?

You can source the FBR K 550/M TL EL EVO through 3G Electric, an established industrial equipment distributor since 1990. We handle logistics, customs clearance, and delivery to Singapore, providing technical support for dual-fuel burner applications in local industrial heating and power-generation projects.

How to install and maintain the FBR K 550/M TL EL EVO burner?

Installation requires mounting the burner on the boiler using the supplied flange and gasket, connecting flexible hoses and line filter, and wiring the 3~400V supply. Maintenance includes periodic cleaning of the fan, combustion head, and gas train components, plus checking the independent servomotors for air, gas, and light-oil modulation as per FBR's manual.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
K 450/M TL EL EVO (1) | Variant: variant_2 | Subgroup: Gas trains (1)
FBR
K 450/M TL EL EVO (1) | Variant: variant_2 | Subgroup: Gas trains (1)
K 4/M/2 TL EL EVO 2 | Variant: variant_2 | Subgroup: Burner
FBR
K 4/M/2 TL EL EVO 2 | Variant: variant_2 | Subgroup: Burner
K 350/M TL EL EVO (1) | Variant: variant_2 | Subgroup: Burner with electronic cam
FBR
K 350/M TL EL EVO (1) | Variant: variant_2 | Subgroup: Burner with electronic cam
K 4/2 TL EVO 2 | Variant: variant_2 | Subgroup: Burner
FBR
K 4/2 TL EVO 2 | Variant: variant_2 | Subgroup: Burner
K 4/M/2 TC EL EVO 2 | Variant: variant_2 | Subgroup: Burner
FBR
K 4/M/2 TC EL EVO 2 | Variant: variant_2 | Subgroup: Burner
K 550/M TL EL EVO (1) | Variant: metano | Subgroup: Gas trains (1)
FBR
K 550/M TL EL EVO (1) | Variant: metano | Subgroup: Gas trains (1)

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL