The KDR LINE REACTORS Input Line Reactor: Open (MPN KDRC3H) is a High Z, 27 A Output Current - Max device rated for 460/480V AC and 20 hp Max Output Power.

SKU 3G-OTH-622358

Brand
KDR LINE REACTORS
Item
KDRC3H Input Line Reactor
Part Number
KDRC3H
Category
Input Line Reactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. Bank transfer and corporate PO accepted.

Technical Specifications

KDR LINE REACTORS
Manufacturer Part Number
KDRC3H
Type
High Z, 27 A Output Current - Max
AC
460/480V
Max Output Power
20 hp

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Ask a question

Request a Quote

Ask a question

KDR LINE REACTORS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The KDR LINE REACTORS Input Line Reactor: Open (MPN KDRC3H) is a High Z, 27 A Output Current - Max device rated for 460/480V AC and 20 hp Max Output Power.

Frequently Asked Questions

What is the KDR LINE REACTORS KDRC3H input line reactor used for?

The KDR LINE REACTORS KDRC3H input line reactor protects variable frequency drives and motor controllers from power line harmonics, voltage spikes, and current distortion. It is rated for 460/480V AC, 27 A output current, and 20 hp max output power, making it suitable for industrial motor drive applications.

What are the specifications of the KDR LINE REACTORS KDRC3H?

The KDR LINE REACTORS KDRC3H is an open-style input line reactor with High Z impedance. It operates at 460/480V AC, handles 27 A output current maximum, and supports up to 20 hp max output power. The manufacturer part number is KDRC3H.

Where to buy the KDR LINE REACTORS KDRC3H worldwide?

3G Electric supplies the KDR LINE REACTORS KDRC3H input line reactor worldwide. We handle full logistics, customs clearance, and delivery to your facility. Contact us to order this OEM-specified component for your industrial motor drive system.

How to select the right input line reactor for a 460V drive?

Select an input line reactor like the KDR LINE REACTORS KDRC3H by matching voltage (460/480V AC), current rating (27 A), and impedance type (High Z) to your drive's specifications. Ensure the reactor's max output power (20 hp) meets or exceeds your motor load. Consult the drive manual for recommended reactor values.

Not sure this is the right part? Photo-identify it→

KDR LINE REACTORS Products

3G Electric supplies KDR LINE REACTORS input line reactors. We supply genuine products and their technical documentation.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

More from KDR LINE REACTORS

View all KDR LINE REACTORS parts →
Open-style input line reactor rated for 460/480V AC with a maximum output current of 240 A and maximum output power of 200 hp. Provides high impedance to reduce harmonics, limit inrush current, and smooth voltage spikes in motor drive systems. Suitable for use with variable frequency drives and other industrial equipment requiring input line reactance
KDR LINE REACTORS
Open-style input line reactor rated for 460/480V AC with a maximum output current of 240 A and maximum output power of 200 hp. Provides high impedance to reduce harmonics, limit inrush current, and smooth voltage spikes in motor drive systems. Suitable for use with variable frequency drives and other industrial equipment requiring input line reactance
This input line reactor is designed for use with variable frequency drives and motor controllers to mitigate power line harmonics, surges, and voltage spikes. Rated for 208/240V AC, 12 A output current, and 3 hp maximum output power, it is suitable for 3-phase systems in industrial automation and HVAC applications
KDR LINE REACTORS
This input line reactor is designed for use with variable frequency drives and motor controllers to mitigate power line harmonics, surges, and voltage spikes. Rated for 208/240V AC, 12 A output current, and 3 hp maximum output power, it is suitable for 3-phase systems in industrial automation and HVAC applications
Open-style input line reactor rated for 460/480V AC systems. High impedance design with 750 A maximum output current and 600 hp maximum output power. Used to protect variable frequency drives and motor control equipment from power line disturbances such as harmonics, spikes, and voltage transients
KDR LINE REACTORS
Open-style input line reactor rated for 460/480V AC systems. High impedance design with 750 A maximum output current and 600 hp maximum output power. Used to protect variable frequency drives and motor control equipment from power line disturbances such as harmonics, spikes, and voltage transients
Open-style low-impedance input line reactor rated for 575/600V AC, 32 A maximum output current, and 30 hp maximum output power. Used with variable frequency drives and motor controllers to reduce harmonics, voltage spikes, and current distortion in industrial motor-drive applications
KDR LINE REACTORS
Open-style low-impedance input line reactor rated for 575/600V AC, 32 A maximum output current, and 30 hp maximum output power. Used with variable frequency drives and motor controllers to reduce harmonics, voltage spikes, and current distortion in industrial motor-drive applications
Low-impedance input line reactor for variable frequency drives and motor controllers. Rated 460/480V AC, 720 A maximum output current, 600 hp maximum output power. Open-style construction. Reduces harmonics, voltage spikes, and current distortion in industrial automation, HVAC, pumping, and conveyor systems
KDR LINE REACTORS
Low-impedance input line reactor for variable frequency drives and motor controllers. Rated 460/480V AC, 720 A maximum output current, 600 hp maximum output power. Open-style construction. Reduces harmonics, voltage spikes, and current distortion in industrial automation, HVAC, pumping, and conveyor systems
This open-style input line reactor is designed for 575/600V AC systems with a maximum output current of 4.8 A and a maximum output power of 3 hp. It features low impedance construction to reduce harmonics, voltage spikes, and current distortion in motor drive applications. Typical uses include protecting variable frequency drives and motors in industrial automation, HVAC, and pumping systems
KDR LINE REACTORS
This open-style input line reactor is designed for 575/600V AC systems with a maximum output current of 4.8 A and a maximum output power of 3 hp. It features low impedance construction to reduce harmonics, voltage spikes, and current distortion in motor drive applications. Typical uses include protecting variable frequency drives and motors in industrial automation, HVAC, and pumping systems
High Z input line reactor for 460/480V AC systems, rated for 20 hp maximum output power with 108 W watts loss. Used in motor drive applications to reduce harmonics, limit inrush current, and smooth voltage spikes
KDR LINE REACTORS
High Z input line reactor for 460/480V AC systems, rated for 20 hp maximum output power with 108 W watts loss. Used in motor drive applications to reduce harmonics, limit inrush current, and smooth voltage spikes
This input line reactor is a High Z type rated for 600V AC, 2.1 A maximum output current, and 1 hp maximum output power. It is enclosed in a UL Type 1 housing for indoor use. The reactor conditions incoming AC power to motor drives, reducing harmonics and limiting voltage spikes
KDR LINE REACTORS
This input line reactor is a High Z type rated for 600V AC, 2.1 A maximum output current, and 1 hp maximum output power. It is enclosed in a UL Type 1 housing for indoor use. The reactor conditions incoming AC power to motor drives, reducing harmonics and limiting voltage spikes