Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

KDR LINE REACTORS Input Line Reactor: UL Type 1, High Z, 0.5 hp Max Output Power, 208/240V AC - Input Line Reactors
KDR LINE REACTORSInput Line Reactors

KDR LINE REACTORS Input Line Reactor: UL Type 1, High Z, 0.5 hp Max Output Power, 208/240V AC

The KDR LINE REACTORS Input Line Reactor (UL Type 1, MPN KDRMA22H1E01) is a High Z reactor rated for 0.5 hp max output power at 208/240V AC with 6.8 W watts loss. 3G Electric interprets your demand for this…

SKU 3G-OTH-622492

Brand
KDR LINE REACTORS
Item
Input Line Reactor: UL Type 1, High Z, 0.5 hp Max Output Power, 208/240V AC
Category
Input Line Reactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

KDR LINE REACTORS
Manufacturer Part Number
KDRMA22H1E01
Type
High Z
AC
208/240V
Watts Loss
6.8 W
Max Output Power
0.5 hp

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

KDR LINE REACTORS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The KDR LINE REACTORS Input Line Reactor (UL Type 1, MPN KDRMA22H1E01) is a High Z reactor rated for 0.5 hp max output power at 208/240V AC with 6.8 W watts loss. 3G Electric interprets your demand for this OEM-specified component and delivers it across 14 industrial departments — with specialist depth in combustion, pumps and controls as an authorised distributor.

Frequently Asked Questions

What is a KDR line reactor used for?

A KDR line reactor protects variable frequency drives and motor controls from power line disturbances. It reduces harmonics, limits inrush current, and smooths voltage spikes. 3G Electric supplies this KDRMA22H1E01 High Z reactor for industrial applications across 14 departments, with specialist depth in combustion, pumps and controls.

What are the specifications of the KDRMA22H1E01 input line reactor?

The KDRMA22H1E01 is a UL Type 1, High Z input line reactor rated for 0.5 hp max output power at 208/240V AC with 6.8 W watts loss. It is designed for industrial motor drive protection. 3G Electric sources this OEM-specified component from KDR LINE REACTORS and delivers it worldwide.

Where to buy a KDR line reactor worldwide?

3G Electric supplies the KDRMA22H1E01 input line reactor to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. As a global industrial solutions provider, we interpret your demand and deliver genuine KDR LINE REACTORS components across 14 industrial departments.

How to select the right input line reactor for a VFD?

Select an input line reactor based on motor horsepower, voltage, and impedance type. For the KDRMA22H1E01, match the 0.5 hp max output power and 208/240V AC rating to your drive. High Z reactors offer greater harmonic attenuation. 3G Electric can help you choose the correct KDR LINE REACTORS model for your application.

KDR LINE REACTORS Products

3G Electric supplies KDR LINE REACTORS input line reactors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from KDR LINE REACTORS

View all KDR LINE REACTORS parts
This input line reactor is designed for use with variable frequency drives and motor systems to reduce harmonics, limit inrush current, and smooth voltage spikes. Rated for 575/600V AC, 50 hp max output power, and 165 W watts loss, it is a High Z type with UL Type 1 enclosure
KDR LINE REACTORS
This input line reactor is designed for use with variable frequency drives and motor systems to reduce harmonics, limit inrush current, and smooth voltage spikes. Rated for 575/600V AC, 50 hp max output power, and 165 W watts loss, it is a High Z type with UL Type 1 enclosure
Open-style input line reactor for three-phase AC power systems. Rated 575/600V AC, 130 A maximum output current, 125 hp maximum output power. High impedance design reduces harmonic distortion, voltage spikes, and line notching in motor drive applications
KDR LINE REACTORS
Open-style input line reactor for three-phase AC power systems. Rated 575/600V AC, 130 A maximum output current, 125 hp maximum output power. High impedance design reduces harmonic distortion, voltage spikes, and line notching in motor drive applications
Open-style low-impedance input line reactor rated for 125 hp max output power at 208/240V AC with 377 A max output current. Used to protect variable frequency drives and power electronics from harmonics, voltage spikes, and current distortion in industrial motor control and power transmission systems
KDR LINE REACTORS
Open-style low-impedance input line reactor rated for 125 hp max output power at 208/240V AC with 377 A max output current. Used to protect variable frequency drives and power electronics from harmonics, voltage spikes, and current distortion in industrial motor control and power transmission systems
Open-style low impedance input line reactor rated for 100 hp max output power at 208/240V AC, with a maximum output current of 280 A. Designed to protect variable frequency drives and motor controllers from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, and pump systems
KDR LINE REACTORS
Open-style low impedance input line reactor rated for 100 hp max output power at 208/240V AC, with a maximum output current of 280 A. Designed to protect variable frequency drives and motor controllers from power line harmonics, voltage spikes, and current distortion in industrial automation, HVAC, and pump systems
High Z input line reactor for AC motor drives, rated 25 hp at 460/480V AC with 112 W power loss. Provides harmonic filtering and surge protection to reduce power line disturbances in industrial motor systems
KDR LINE REACTORS
High Z input line reactor for AC motor drives, rated 25 hp at 460/480V AC with 112 W power loss. Provides harmonic filtering and surge protection to reduce power line disturbances in industrial motor systems
This input line reactor is designed for use with variable frequency drives and motor systems to mitigate power surges and harmonics. Rated for 575/600V AC with a maximum output current of 32 A and maximum output power of 30 hp, it features a Low Z design and UL Type 1 enclosure. Typical applications include industrial automation, HVAC, and pump installations
KDR LINE REACTORS
This input line reactor is designed for use with variable frequency drives and motor systems to mitigate power surges and harmonics. Rated for 575/600V AC with a maximum output current of 32 A and maximum output power of 30 hp, it features a Low Z design and UL Type 1 enclosure. Typical applications include industrial automation, HVAC, and pump installations
Low Z input line reactor rated for 575/600V AC, 0.75 hp max output power, 10.9 W watts loss. Used to protect variable frequency drives and motor controllers from power line harmonics and voltage spikes, smoothing current draw and reducing electrical noise in industrial automation, HVAC, and pump systems
KDR LINE REACTORS
Low Z input line reactor rated for 575/600V AC, 0.75 hp max output power, 10.9 W watts loss. Used to protect variable frequency drives and motor controllers from power line harmonics and voltage spikes, smoothing current draw and reducing electrical noise in industrial automation, HVAC, and pump systems
High impedance input line reactor for variable frequency drives and motor controllers. Rated 0.75 hp max output power at 208/240V AC with 12.9 W power loss. Reduces harmonics and voltage spikes in industrial automation, HVAC, and pumping systems
KDR LINE REACTORS
High impedance input line reactor for variable frequency drives and motor controllers. Rated 0.75 hp max output power at 208/240V AC with 12.9 W power loss. Reduces harmonics and voltage spikes in industrial automation, HVAC, and pumping systems