Send a part number, a photo, or a whole BOM — we supply it and stand behind it. EXW Singapore — collect from our office.

3G Electric
KDR LINE REACTORS KDRULF26LE01 Input Line Reactor - Input Line Reactors
KDR LINE REACTORSInput Line Reactors

KDR LINE REACTORS KDRULF26LE01 Input Line Reactor

The KDR LINE REACTORS Input Line Reactor: UL Type 1 is a Low Z reactor with 50 hp Max Output Power, rated for 208/240V AC and 154 W Watts Loss (MPN KDRULF26LE01). 3G Electric interprets this demand and sources the…

SKU 3G-OTH-622521

Brand
KDR LINE REACTORS
Item
KDRULF26LE01 Input Line Reactor
Part Number
KDRULF26LE01
Category
Input Line Reactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. Bank transfer and corporate PO accepted.

Technical Specifications

KDR LINE REACTORS
Manufacturer Part Number
KDRULF26LE01
Type
Low Z
AC
208/240V
Watts Loss
154 W
Max Output Power
50 hp

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Ask a question

Request a Quote

Ask a question

KDR LINE REACTORS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The KDR LINE REACTORS Input Line Reactor: UL Type 1 is a Low Z reactor with 50 hp Max Output Power, rated for 208/240V AC and 154 W Watts Loss (MPN KDRULF26LE01). 3G Electric interprets this demand and sources the genuine KDR component, backed by specialist expertise across 14 industrial departments — including combustion, pumps and controls — to ensure the right solution for your application.

Frequently Asked Questions

What is a KDR Input Line Reactor used for?

A KDR Input Line Reactor protects variable frequency drives and motor systems from power line disturbances, harmonics, and voltage spikes. It reduces electrical noise and extends equipment life in industrial applications across machining, HVAC, and material handling. 3G Electric sources this genuine KDR component for global delivery.

What are the specifications of the KDRULF26LE01 line reactor?

The KDRULF26LE01 is a Low Z input line reactor rated for 208/240V AC, 50 hp max output power, and 154 W watts loss. It is UL Type 1 enclosed. These specs ensure compatibility with standard industrial motor drives. 3G Electric supplies this KDR reactor with full logistics support worldwide.

Where to buy KDR line reactors worldwide?

3G Electric supplies KDR line reactors worldwide, handling full logistics, customs clearance, and delivery to your site. As a global industrial solutions provider, we source genuine KDR components like the KDRULF26LE01 and support your application across 14 departments, including pumps and controls.

How to select the right KDR line reactor for a motor drive?

Select a KDR line reactor by matching voltage (e.g., 208/240V AC), horsepower (e.g., 50 hp), and impedance type (Low Z) to your drive's requirements. Verify watts loss and enclosure type for thermal and environmental fit. 3G Electric's specialists can help interpret your demand and source the correct KDR reactor.

Not sure this is the right part? Photo-identify it→

KDR LINE REACTORS Products

3G Electric supplies KDR LINE REACTORS input line reactors. We supply genuine products and their technical documentation.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from KDR LINE REACTORS

View all KDR LINE REACTORS parts →
Open-style input line reactor rated for 460/480V AC with a maximum output current of 240 A and maximum output power of 200 hp. Provides high impedance to reduce harmonics, limit inrush current, and smooth voltage spikes in motor drive systems. Suitable for use with variable frequency drives and other industrial equipment requiring input line reactance
KDR LINE REACTORS
Open-style input line reactor rated for 460/480V AC with a maximum output current of 240 A and maximum output power of 200 hp. Provides high impedance to reduce harmonics, limit inrush current, and smooth voltage spikes in motor drive systems. Suitable for use with variable frequency drives and other industrial equipment requiring input line reactance
This input line reactor is designed for use with variable frequency drives and motor controllers to mitigate power line harmonics, surges, and voltage spikes. Rated for 208/240V AC, 12 A output current, and 3 hp maximum output power, it is suitable for 3-phase systems in industrial automation and HVAC applications
KDR LINE REACTORS
This input line reactor is designed for use with variable frequency drives and motor controllers to mitigate power line harmonics, surges, and voltage spikes. Rated for 208/240V AC, 12 A output current, and 3 hp maximum output power, it is suitable for 3-phase systems in industrial automation and HVAC applications
Open-style input line reactor rated for 460/480V AC systems. High impedance design with 750 A maximum output current and 600 hp maximum output power. Used to protect variable frequency drives and motor control equipment from power line disturbances such as harmonics, spikes, and voltage transients
KDR LINE REACTORS
Open-style input line reactor rated for 460/480V AC systems. High impedance design with 750 A maximum output current and 600 hp maximum output power. Used to protect variable frequency drives and motor control equipment from power line disturbances such as harmonics, spikes, and voltage transients
Open-style low-impedance input line reactor rated for 575/600V AC, 32 A maximum output current, and 30 hp maximum output power. Used with variable frequency drives and motor controllers to reduce harmonics, voltage spikes, and current distortion in industrial motor-drive applications
KDR LINE REACTORS
Open-style low-impedance input line reactor rated for 575/600V AC, 32 A maximum output current, and 30 hp maximum output power. Used with variable frequency drives and motor controllers to reduce harmonics, voltage spikes, and current distortion in industrial motor-drive applications
Low-impedance input line reactor for variable frequency drives and motor controllers. Rated 460/480V AC, 720 A maximum output current, 600 hp maximum output power. Open-style construction. Reduces harmonics, voltage spikes, and current distortion in industrial automation, HVAC, pumping, and conveyor systems
KDR LINE REACTORS
Low-impedance input line reactor for variable frequency drives and motor controllers. Rated 460/480V AC, 720 A maximum output current, 600 hp maximum output power. Open-style construction. Reduces harmonics, voltage spikes, and current distortion in industrial automation, HVAC, pumping, and conveyor systems
This open-style input line reactor is designed for 575/600V AC systems with a maximum output current of 4.8 A and a maximum output power of 3 hp. It features low impedance construction to reduce harmonics, voltage spikes, and current distortion in motor drive applications. Typical uses include protecting variable frequency drives and motors in industrial automation, HVAC, and pumping systems
KDR LINE REACTORS
This open-style input line reactor is designed for 575/600V AC systems with a maximum output current of 4.8 A and a maximum output power of 3 hp. It features low impedance construction to reduce harmonics, voltage spikes, and current distortion in motor drive applications. Typical uses include protecting variable frequency drives and motors in industrial automation, HVAC, and pumping systems
High Z input line reactor for 460/480V AC systems, rated for 20 hp maximum output power with 108 W watts loss. Used in motor drive applications to reduce harmonics, limit inrush current, and smooth voltage spikes
KDR LINE REACTORS
High Z input line reactor for 460/480V AC systems, rated for 20 hp maximum output power with 108 W watts loss. Used in motor drive applications to reduce harmonics, limit inrush current, and smooth voltage spikes
This input line reactor is a High Z type rated for 600V AC, 2.1 A maximum output current, and 1 hp maximum output power. It is enclosed in a UL Type 1 housing for indoor use. The reactor conditions incoming AC power to motor drives, reducing harmonics and limiting voltage spikes
KDR LINE REACTORS
This input line reactor is a High Z type rated for 600V AC, 2.1 A maximum output current, and 1 hp maximum output power. It is enclosed in a UL Type 1 housing for indoor use. The reactor conditions incoming AC power to motor drives, reducing harmonics and limiting voltage spikes

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first