Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
AllansonUV Ballasts

Allanson UVB50W-800-12VDC UV Ballast – Program Start

3G-OTH-03047 UV BALLASTS – Program Start

SKU 3G-OTH-03047

Also listed as: UVB50W80012VDC · UVB50W 800 12VDC

Brand
Allanson
Item
UVB50W-800-12VDC UV Ballast – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Size
7.80"x2.0"x1.35"
Lamps
1
Weight
2.2 lb
Lamp mA
800
Lamp Type
High-output
Input Lamps
1
Lamp Length
8" to 16"
Potted Case
PC Board
Input Voltage
12V
Input Wattage
50

Datasheet Content

[{"filename":"3G-OTH-03047.pdf","text":"Specifications Sheet\n UV Ballasts\nUVB50W-800-12VDC\n1. Lamp Type\n Lamp Type / Cata # Manufacture # of Lamps Power (W) Current (mA)\n\n GHO200T5L/4P Light Sources 1 25 800\n\n GHO250T5L/4P Light Sources 1 32 800\n\n GHO300T5L/4P Light Sources 1 38 800\n\n GHO350T5L/4P Light Sources 1 44 800\n\n GHO400T5L/4P Light Sources 1 50 800\n\n\n2. Electrical\nBallast type: Program Start (PS)\nNumber of lamps: 1\nNormal input voltage: 12VDC, +/- 10%\nInput current: 4.25A\nInput power: 50W @ full load\nLamp operating frequency: > 35 kHz\nEfficiency: > 90%\nBallast shut down/protection: EOL/OC\nAmbient temperature: 0 - 40° C\nCase maximum temperature: 75° C\nApprovals: UL/cUL Listed, Class \"P\"\nSound rating: “A”\n\n\n3. Wiring Diagram 4. Mechanical Data\n Dimensions: 7.80\" (L) x 2.0\" (W) x 1.35\" (H)\n\n\n\n\n 83 Commerce Valley Drive East, Markham ON, L3T 7T3\n www.allanson.com | cservice@allanson.com | T: 1.800.661.7251 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03047 UV BALLASTS – Program Start

Frequently Asked Questions

What is the Allanson 3G-OTH-03047 UV ballast used for?

The Allanson 3G-OTH-03047 is a program-start UV ballast designed to power single high-output UV lamps, such as the GHO200T5L/4P through GHO400T5L/4P, in water treatment, air purification, and industrial disinfection systems.

What are the specifications of the Allanson 3G-OTH-03047?

The Allanson 3G-OTH-03047 operates at 12 VDC input, draws 4.25 A, delivers 50 W, and drives one high-output lamp at 800 mA. It measures 7.80" x 2.0" x 1.35", weighs 2.2 lb, and is UL/cUL Listed with Class "P" protection.

Where to buy the Allanson 3G-OTH-03047 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03047 UV ballast to Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this program-start ballast.

How to install the Allanson 3G-OTH-03047 UV ballast?

Mount the Allanson 3G-OTH-03047 in a dry, ventilated area with ambient temperature between 0–40 °C. Connect the 12 VDC supply per the wiring diagram, ensuring correct polarity. Use only compatible high-output lamps listed in the datasheet for safe operation.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB50W-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-120-240V-TA UV Ballast – Program Start
Allanson
Allanson
Allanson UVB80W-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-120-240V-PD UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-24V-TA UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100W-425-120-240V UV Ballast – Program Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB248T5-425-MV UV Ballast – Instant Start