Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Fireye 57AV7 Universal Test Unit - Training Units & Testing Units
FireyeTraining Units & Testing Units

Fireye 57AV7 Universal Test Unit

Fireye test unit Type 3G-OTH-02843 Model 1000 provides a simple and convenient means to field-test the Fireye M-Series, M-Series II and MicroM controls.

SKU 3G-OTH-02843

Brand
Fireye
Item
57AV7 Universal Test Unit
Category
Training Units & Testing Units
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Fireye
Models
57AV7
Category
Training Units & Testing Units

Datasheet Content

[{"filename":"CU-90-Universal_Test_Unit_57AV7_English_2013-04-11.pdf","text":"®\n\n C-90\n APRIL 11, 2013\n\n\n\n\n Type 3G-OTH-02843 Model 1000\n UNIVERSAL TEST UNIT\n FOR M-SERIES, M-SERIES II\n or MicroM CONTROLS\n\nDESCRIPTION\n Fireye test unit Type 3G-OTH-02843 Model 1000 provides a simple and convenient means to field-test the\n Fireye M-Series, M-Series II and MicroM controls.I\n\n MODEL1 PURGE2 FFRT RELIGHT RECYCLE3 NON- FLAME BULLETIN\n RECYCLE3 DETECTOR\nUVM1D or MP100 w/MAUV1T 0.8 X UV C-4000 or MC-5000\nor MEP100 w/MEUV1\nUVM1F or MP100 w/MAUV1 2-4 X UV C-4000 or MC-5000\nor MEP100 w/MEUV4\nTFM1D or MP100 w/MART1T 0.8 X Rod/P.C. C-4000 or MC-5000\nor MEP100 w/MERT1\nTFM1F or MP100 w/MART1 2-4 X Rod/P.C. C-4000 or MC-5000\nor MEP100 w/MERT4\nUVM2-2A or MP230 w/ MAUV1 X 2-4 X UV C-4000 or MC-5000\nor MEP230 w/MEUV4\nTFM2-2A or MP230 w/MART1 X 2-4 X Rod/P.C. C-4000 or MC-5000\nor MEP230 w/MERT4\nUVM3 or MP230 w/MAUV1 X 2-4 X UV C-4000 or MC-5000\nor MEP 230 w/MEUV4\nTFM3 or MP230 w/MART1 X 2-4 X Rod/P.C. C-4000 or MC-5000\nor MEP230 w/MERT4\nUVM3H X 2-4 X UV C-400\nTFM3H X 2-4 X Rod/P.C. C-400\nUVM5 or MP560 w/MAUV1 X 2-4 X UV C-4000 or MC-5000\nor MEP560 w/MEUV4\nMP560 w/MART1 X 2-4 Rod/P.C. C-4000 or MC-5000\nor MEP560 w/MERT4\nUVM64 or MP560, MP561, X 2-4 X UV C-4000 or MC-5000\nMP562 w/MAUVF1, MAUV1\nor MEP560, MEP561, MEP562\nw/MEUV4\n1. All M-Series II controls use the MC120 chassis.\n2. Purge timing is determined via timing card on M-Series controls, via dipswitches on M-Series II and MicroM controls.\n3. Recycle or Non-Recycle operation is determined via dipswitches on M-Series II and MicroM controls. MP100 programmer is recycle operation only.\n4. Clip red jumper on UVM6 to make non-recycle.\n5. All MircoM controls use the MC120 chassis.\n\n\n\n 1\n\f \n\n\n\n\nINSTALLATION\n The Type 3G-OTH-02843 tester is intended primarily for portable use. However, when a fixed installation is\n needed, the four rubber feet on the back may be removed and screws or both used to mount the unit.\n The tester is provided with a three-prong plug on the line cord. If an adapter is used for a two-wire\n outlet, the pigtail should be reliably grounded. When a Fireye chassis is plugged into the test unit, a\n complete burner firing operation can be simulated and checked through the use of switches.\n\n\nMOUNTING DIMENSIONS\n 1/2 4 3/16 DIA. MTG. HOLES\n (4 FAR SIDE)\n\n 1/2\n\n\n\n\n 9 1/8\n M-SERIES DEMONSTRATOR 10 1/8\n\n ON ON\n UV\n\n OFF OFF\n OFF OFF\n OPERATING INTERLOCK\n CONTROL FR\n FLAME\n\n\n\n\n BLOWER PILOT SPARK MAIN ALARM\n MOTOR 1 AMP FUEL\n ON\n\n\n\n\n FUSE OFF\n POWER\n\n 2 3/16\n 5 2 7/8\n\n\n\n\nPANEL COMPONENT IDENTIFICATION\n 1. Power Switch: Simulates the main disconnect switch, connected between the hot line and termi-\n nal 1.\n 2. Operating Switch: Simulates the limit switches and operating controls, connected between ter-\n minals 1 and 7.\n 3. Interlock Switch: Simulates an air flow switch or other interlocking devices, connected between\n terminals 8 and 6.\n 4. Flame Switch: Simulates an operating flame detector — in FR position, a flame rod or photo-\n cell; in UV position, a U-V-eye scanner. The center position of the switch is OFF.\n\n\n2\n\f ®\n\n\n\n 5. Blower Motor Lamp (white): Simulates the burner/blower motor — connected to terminals 8\n and 2.\n 6. Pilot Lamp (amber): Simulates the pilot fuel valve, connected to terminals 3 and 2.\n 7. Spark Lamp (amber): Simulates the ignition transformer, connected to terminals 4 and 2.\n 8. Main Fuel Lamp (amber): Simulates the main fuel valve, connected to terminals 5 and 2.\n 9. Alarm Lamp (red): Simulates the lockout alarm, connected to terminals A and 2.\n\nPROCEDURE\n 1. Refer to bulletins C-400, C-4000 or MC-5000 for the detailed description of operation for the\n specific control being tested.\n 2. Turn all switches to OFF before installing the control chassis.\n 3. Install the control chassis and securely tighten the two retaining screws.\n 4. Reset the control lockout switch.\n\nOPERATING TEST\n Complete Cycle\n 1. Turn POWER switch to ON position.\n 2. Turn OPERATING switch to ON position. Blower motor light turns on.\n 3. Turn INTERLOCK switch to ON position.\n — UVM1 and TFM1 controls and MP100 or MEP100 programmers will pause for a few sec-\n onds (safe start check) before energizing terminals 3 (Pilot) and 4 (Spark), initiating a 10-\n second trial for ignition period. Proceed to step 5.\n — All other M-Series controls and programmer modules will begin their purge period (deter-\n mined via timing card on the M-Series controls, via dipswitches on the M-Series II or\n MicroM controls).\n 4. At the end of the purge period, terminals 3 (Pilot) and 4 (Spark) are energized, initiating the trial\n for ignition period (determined via timing card on the M-Series controls, via dipswitches on the\n M-Series II or MicroM controls).\n 5. Turn “flame” switch to the UV position (ultra-violet) for the UVM controls, MAUV1,\n MAUV1T, MEUV1 or MEUV4 amplifiers. Turn “flame” switch to the FR position (flame recti-\n fication) for the TFM controls, MART1, MART1T, MERT1 or MERT4 amplifiers.\n — On UVM1, TFM1, UVM2, TFM2 controls and MP100, MP230 programmers: When flame\n is detected, the “main fuel” light (term 5) is energized, the “spark” light (term 4) turns off.\n — On UVM3H, TFM3H controls and MP230H programmers: There is a 5 to 8 second delay\n after flame is detected before the “main fuel” light is energized and the “spark” light is de-\n energized.\n — On UVM5, UVM6 controls and MP560, MP562, MEP560 and MEP562 programmers:\n There is an 8 second delay after flame is detected before the “main fuel” light is energized.\n 10 seconds after the “main fuel” light is energized, the “spark” light is de-energized.\n — On the MP561 or MEP561 programmers: When flame is detected, the “main fuel” light is\n energized. 10 seconds after the “main fuel” light is energized, the “spark” light is de-ener-\n gized.\n Ignition Failure\n For all controls.:During a regular start, after the “pilot” (term 3) and “spark” (term 4) lights are ener-\n gized, leave the flame selector switch in the “off” position. At the end of the trial for ignition period\n (determined via timing card on the M-Series controls, via dipswitches on the M-Series II or MicroM\n controls), the “pilot” and “spark” lights are de-energized. The control will lockout. The “alarm” light\n turns on. Manual reset is required.\n\n\n\n\n 3\n\f \n\n\n\n Flame Failure\n Following a normal startup, when the running position is reached, turn the FLAME switch to OFF.\n 1. UVM-1F, UVM-1D, TFM-1F and TFM-1D; the “main fuel” light ill turn off within\n — 0.8 seconds: UVM-1D, TFM-1D.\n — 2-4 seconds: UVM-1F, TFM-1F.\n The “spark” light turns on. A 10 to 12 second relight interval is initiated, after which a safety shut-\n down occurs. Manual reset is required prior to a restart.\n 2. UVM2, 2A, TFM2, 2A: The “main fuel” and “pilot” lights turn off within 2 seconds. The purge\n period is re-initiated after which the “pilot” and “spark” lights turn on. A 10…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fireye Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Fireye test unit Type 3G-OTH-02843 Model 1000 provides a simple and convenient means to field-test the Fireye M-Series, M-Series II and MicroM controls.

Frequently Asked Questions

What is the Fireye 3G-OTH-02843 Universal Test Unit used for?

The Fireye 3G-OTH-02843 Universal Test Unit Model 1000 is used to field-test Fireye M-Series, M-Series II, and MicroM controls. It simulates a complete burner firing operation through switches, allowing technicians to verify control functionality without connecting to an actual burner system.

What are the specifications of the Fireye 3G-OTH-02843?

The Fireye 3G-OTH-02843 Universal Test Unit Model 1000 is designed for portable use with a three-prong plug on the line cord. It supports M-Series, M-Series II, and MicroM controls using an MC120 chassis. Mounting dimensions are 9 1/8 inches by 10 1/8 inches with four 3/16-inch diameter mounting holes.

Where to buy the Fireye 3G-OTH-02843 in Singapore?

You can source the Fireye 3G-OTH-02843 Universal Test Unit through 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your location. Contact us for availability and lead time on this test unit for M-Series and MicroM controls.

How to install the Fireye 3G-OTH-02843 test unit?

The Fireye 3G-OTH-02843 is primarily portable but can be mounted by removing the four rubber feet and using screws through the 3/16-inch diameter holes. Plug the three-prong line cord into a grounded outlet. When a Fireye chassis is plugged in, use the panel switches to simulate burner operation for testing.

Used in

Common applications for Fireye
Power-plant auxiliary boiler — M-Series II controller with UV flame scanner, programmed for gas/oil switchover and flame-presence monitoring.
Refinery process heater — MP100E programmer module managing multi-stage ignition and flame-out shutdown interlocks on high-pressure burners.
Petrochemical facility thermal oxidizer — MAUV1T UV amplifier module processing scanner signal from high-temperature burner housings with immune-response filtering.
Large-scale industrial oven (metal treating) — M-Series II with remote reset capability and dual-fuel solenoid isolation for operator safety and burner protection.
Cogeneration plant fuel-gas burner — Fireye scanner and modular controller stack integrated into BMS with remote monitoring of flame status and controller fault codes.

Fireye Products

3G Electric supplies Fireye training units & testing units. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
M-Series II Amplifier Modules. The Fireye MART1, MART3, MART1T, MAUV1, MAUV3, and MAUV1T are advanced Amplifier Modules designed for use with the Fireye Modular M-SERIES II Control. These versatile amplifier modules are essential for flame scanning, offering compatibility with Fireye’s standard ultraviolet (UV) scanners and flame rods to ensure accurate flame detection and system performance
Fireye
M-Series II Amplifier Modules. The Fireye MART1, MART3, MART1T, MAUV1, MAUV3, and MAUV1T are advanced Amplifier Modules designed for use with the Fireye Modular M-SERIES II Control. These versatile amplifier modules are essential for flame scanning, offering compatibility with Fireye’s standard ultraviolet (UV) scanners and flame rods to ensure accurate flame detection and system performance
MicroM Amplifier Modules. The Fireye MEUV1, MEUV4, MEUVS1, MEUVS4, MERT1, MERT4, MEIR1, MEIR4, MECD1, and MECD4 amplifier modules are designed for use with the Fireye Modular MicroM control system. These modules enable reliable flame scanning using Fireye’s UV, self-check, IR, CdS scanners, and flame rods
Fireye
MicroM Amplifier Modules. The Fireye MEUV1, MEUV4, MEUVS1, MEUVS4, MERT1, MERT4, MEIR1, MEIR4, MECD1, and MECD4 amplifier modules are designed for use with the Fireye Modular MicroM control system. These modules enable reliable flame scanning using Fireye’s UV, self-check, IR, CdS scanners, and flame rods
Flame-Monitor Amplifier Modules. The Fireye E1R1, EUV1, ERT1, and EUVS4 Amplifier Modules are essential components of the Fireye Flame-Monitor System, designed to enhance flame scanning and monitoring. These modules are compatible with various Fireye flame scanning devices, including AutoCheck infrared scanners, standard ultraviolet scanners, flame rods, and ultraviolet self-check scanners. Each module must be selected based on the type of scanner used and inserted into the appropriate Flame-Monitor chassis for optimal performance
Fireye
Flame-Monitor Amplifier Modules. The Fireye E1R1, EUV1, ERT1, and EUVS4 Amplifier Modules are essential components of the Fireye Flame-Monitor System, designed to enhance flame scanning and monitoring. These modules are compatible with various Fireye flame scanning devices, including AutoCheck infrared scanners, standard ultraviolet scanners, flame rods, and ultraviolet self-check scanners. Each module must be selected based on the type of scanner used and inserted into the appropriate Flame-Monitor chassis for optimal performance
Flame scanner for ultraviolet detection of gas or oil flames in industrial burners, boilers, and furnaces. Used in burner management systems to verify flame presence and support safety shutdown functions
Fireye
Flame scanner for ultraviolet detection of gas or oil flames in industrial burners, boilers, and furnaces. Used in burner management systems to verify flame presence and support safety shutdown functions
UV7A4, UV7A4-1-CEX & UV7R4 Flame Scanners. The UV7A4, UV7A4-1-CEX and UV7R4 are high-sensitivity ultraviolet (UV) flame scanners designed for monitoring gas or oil flames that cycle frequently. These non-self-check scanners integrate seamlessly with Fireye’s MBSERIES Multi-Burner control, SBSERIES Single Burner control, and the MBPF-100S and MB-600PF flame sensing modules, providing reliable flame detection for various industrial applications
Fireye
UV7A4, UV7A4-1-CEX & UV7R4 Flame Scanners. The UV7A4, UV7A4-1-CEX and UV7R4 are high-sensitivity ultraviolet (UV) flame scanners designed for monitoring gas or oil flames that cycle frequently. These non-self-check scanners integrate seamlessly with Fireye’s MBSERIES Multi-Burner control, SBSERIES Single Burner control, and the MBPF-100S and MB-600PF flame sensing modules, providing reliable flame detection for various industrial applications
Ultraviolet flame scanner for detecting UV radiation from burner flames. Used in burner management systems for industrial boilers, furnaces, and process heaters to verify flame presence and support safe operation
Fireye
Ultraviolet flame scanner for detecting UV radiation from burner flames. Used in burner management systems for industrial boilers, furnaces, and process heaters to verify flame presence and support safe operation

More from Fireye

View all Fireye parts
BP500 Test Unit for BurnerPRO. The Fireye Test Unit BP500 offers a straightforward and convenient method for field testing Fireye BurnerPRO controls. When a Fireye control chassis is connected to the tester, you can simulate and verify a complete burner firing operation using the panel’s switches and indicator lights. This versatile unit supports all BurnerPRO models up to the third generation
Fireye
BP500 Test Unit for BurnerPRO. The Fireye Test Unit BP500 offers a straightforward and convenient method for field testing Fireye BurnerPRO controls. When a Fireye control chassis is connected to the tester, you can simulate and verify a complete burner firing operation using the panel’s switches and indicator lights. This versatile unit supports all BurnerPRO models up to the third generation
SB Series Training Unit. The Fireye Model 57SB4-1000 Tester provides a convenient means for testing SB Series controllers and sensors. It also is a good tool for learning about the sequences and safety features of all the sbSeries models
Fireye
SB Series Training Unit. The Fireye Model 57SB4-1000 Tester provides a convenient means for testing SB Series controllers and sensors. It also is a good tool for learning about the sequences and safety features of all the sbSeries models
Nexus NX6300 Training Unit. Maximize efficiency and gain mastery over parallel positioning controls with the Nexus NX6300 Training and Demo Unit. The NX-ATU-6300 is designed to help users explore the full potential of the Nexus NX6300 controller, making it ideal for hands-on training and system demonstrations
Fireye
Nexus NX6300 Training Unit. Maximize efficiency and gain mastery over parallel positioning controls with the Nexus NX6300 Training and Demo Unit. The NX-ATU-6300 is designed to help users explore the full potential of the Nexus NX6300 controller, making it ideal for hands-on training and system demonstrations
Nexus Training Units. The Nexus training and demo units (NX-ATU-4000 or NX-ATU-6000) provide users with the ability to familiarize themselves with the functions and features of the Nexus NXF4000, PPC4000, NX6100 and PPC6000 controller range
Fireye
Nexus Training Units. The Nexus training and demo units (NX-ATU-4000 or NX-ATU-6000) provide users with the ability to familiarize themselves with the functions and features of the Nexus NXF4000, PPC4000, NX6100 and PPC6000 controller range
57AV4 Test Unit. Fireye Test Unit type 57AV4 provides a simple convenient means for field testing the Fireye Flame-Monitor with components, and “C” and “D” series controls. When a Fireye control chassis is plugged into the tester, a complete burner firing operation can be simulated and checked through the use of switches and indicating lights on the panel
Fireye
57AV4 Test Unit. Fireye Test Unit type 57AV4 provides a simple convenient means for field testing the Fireye Flame-Monitor with components, and “C” and “D” series controls. When a Fireye control chassis is plugged into the tester, a complete burner firing operation can be simulated and checked through the use of switches and indicating lights on the panel