Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

FBR X G 1.22 2001 SI - Burners & Combustion
FBRBurners & Combustion

FBR X G 1.22 2001 SI

FBR X G 1.22 2001 SI is a two-stage diesel burner for light-oil combustion, delivering 47.4–116 kW thermal power with a 112 mm nozzle. Operating at 1N~230V with 59–61 dBA noise output, it suits industrial heating and…

SKU 3G-FBR-00007

Brand
FBR
Item
X G 1.22 2001 SI
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

FBR
Weight
10 kg
stage
2 stages with jump of pressure
fuel type
Light oil
nozzle mm
112
fan motor w
100
power kw max
116
power kw min
47.4
flow kg h max
9.8
flow kg h min
4
ip protection
IP 40
noisiness dba
59-61
electrical supply
1
power supply info
1N~230V
current absorption a
0.7
thermal power mcal h
22.4/40.8-99.9
nominal electric power w
140
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en LIGHT-OIL BURNERS AT TWO STEPS PRESSURE G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI Light-oil burners at two steps pressure. They are composed by: aluminium frame, protection cover with noise reduction plate, combustion head with micrometric adjustment, high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. In the versions R preheater with control of temperature for soft and sicure ignitions also at low temperatures. Complete of connector 7 poles, flange and gasket for installation on boiler, nozzle, flexible pipes, line filter. Fig. 1 G 1.22R - G 1.22 Fig. 2 G 2.22R MAXI - G 2.22 MAXI G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en TECHNICAL DATA G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI MODEL G 1.22R G 1.22 G 2.22R G 2.22 MAXI MAXI Flow min. 1st st. / min. 2nd st. - max. 2nd st. * [kg/h] 1.4/2.0-5.0 2.2/4-9.8 Thermal power min. 1st st. / min. 2nd st. - max. 2nd st. * [Mcal/h] 14.3/20.4-51 22.4/40.8-99.9 Thermal power min. 1st st. / min. 2nd st. - max. 2nd st. * [kW] 16.6/23.7-59.2 26/47.3-116 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two steps pressure Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [W] 220 130 250 140 Fan motor [W] 100 100 100 100 Nominal current absorption [A] 1 0.6 1.1 0.7 Pre-heater [W] 30-110 - 30-110 - Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness min. - max. ** [dBA] 57-59 57-59 59-61 59-61 Burner weight *** [kg] 10 10 10 10 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the combustion laboratory, with burner on operation on beta boiler to 1m of distance (UNI EN ISO 3746). *** For burner with iron cover (F) add 2 kg to the weight. OPERATING RANGE DIAGRAM G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en DIMENSIONS [MM] Fig. 4 Dimensions G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI MODEL A B C D E F G H I G 1.22 - G 1.22R 157 170 275 80 265 210 15 150 150 G 2.22 MAXI - G 2.22R MAXI 157 170 275 90 265 210 15 150 150 * See "flame tube length" BOILER PLATE ** Suggested dimension of connection between burner and generator. Fig. 5 Boiler plate MODEL L min L ** L max M N min N ** N max G 1.22 - G 1.22R mm 130 150 170 M8 90 110 130 G 2.22 MAXI - G 2.22R MAXI mm 130 150 170 M8 100 110 130 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL *** G 1.22 - G 1.22R mm 112 152 G 2.22 MAXI - G 2.22R MAXI mm 107 147 *** For different flame lengths, please contact our Technical-Sales Department. G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI LIGHT-OIL BURNERS AT TWO STEPS PRESSURE SK070045_A_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners at two steps pressure. DETAILED SPECIFICATION Light-oil burners at two steps pressure, composed by: • Aluminium frame; • Combustion head with micrometric adjustment, high flame stability and low emissions; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Photoresistance for flame detection; • IP 40 electric protection level; • Hydraulic system of regulation combustive air on the two stages of flame. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • 7-poles plug for the electrical connections; • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. G 1.22R - G 1.22 - G 2.22R MAXI - G 2.22 MAXI
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR X G 1.22 2001 SI is a two-stage diesel burner for light-oil combustion, delivering 47.4–116 kW thermal power with a 112 mm nozzle. Operating at 1N~230V with 59–61 dBA noise output, it suits industrial heating and process applications requiring reliable, staged pressure control.

Frequently Asked Questions

What is the FBR X G 1.22 2001 SI diesel burner used for?

The FBR X G 1.22 2001 SI is a two-stage light-oil burner designed for industrial heating and process applications. It delivers 47.4–116 kW thermal power with a 112 mm nozzle, making it suitable for boilers and furnaces requiring reliable staged pressure control.

What are the specifications of the FBR X G 1.22 2001 SI burner?

The FBR X G 1.22 2001 SI operates at 1N~230V with a 100 W fan motor and 0.7 A current absorption. It has a thermal power range of 47.4–116 kW, IP 40 protection, and noise output of 59–61 dBA. The burner weighs 10 kg and uses light oil fuel.

Where to buy the FBR X G 1.22 2001 SI burner in Singapore?

You can source the FBR X G 1.22 2001 SI burner through 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your site. Contact us for availability and lead time on this FBR two-stage diesel burner.

How to install the FBR X G 1.22 2001 SI burner?

Installation should follow the FBR manual and local regulations. Ensure the burner flange and gasket are properly mounted on the boiler. Connect the 7-pole connector, flexible pipes, and line filter. Adjust the combustion head micrometrically for flame stability and verify staged pressure operation.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
X G 0S 2001 S
FBR
X G 0S 2001 S
X G 1H 2001 c
FBR
X G 1H 2001 c
X G oH 2001 c
FBR
X G oH 2001 c
X G X3.22 TC SI
FBR
X G X3.22 TC SI
FBR
FBR
X G 2.22 MAXI SI
X G IS 2001 S
FBR
X G IS 2001 S

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL